A radioligand receptor binding assay for ciguatoxin monitoring in environmental samples: Method development and determination of quality control criteria

被引:17
|
作者
Diaz-Asencio, Lisbet [1 ]
Clausing, Rachel J. [2 ]
Ranada, Ma Llorina [3 ]
Alonso-Hernandez, Carlos M. [1 ]
Bottein, Marie-Yasmine Dechraoui [2 ]
机构
[1] CEAC, Carretera Castillo Jagua Km 1 1 2, Cienfuegos 59350, Cuba
[2] IAEA, Dept Nucl Sci & Applicat, Environm Labs, MC-98000 Monaco, Monaco
[3] PNRI, DOST, Chem Res Sect, IAEA Collaborating Ctr Harmful Algal Bloom HAB St, Quezon City 1101, Philippines
关键词
Ciguatoxins; Environmental monitoring; Fish; Ciguatera; Toxicity; Detection method; Radioligand; Quality control; PARALYTIC SHELLFISH TOXINS; CIGUATERA; IDENTIFICATION;
D O I
10.1016/j.jenvrad.2018.06.019
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ciguatoxins are algal toxins responsible for tens of thousands of human intoxications yearly, both in tropical and subtropical endemic regions as well as worldwide through fish exportation. Previously developed methods for biotoxin surveillance in the environment and seafood include analytical methods and in vivo and in vitro bioassays. The radioligand receptor binding assay (r-RBA) is among the in vitro methodologies currently used for the detection and quantification of marine biotoxins. For the ciguatoxin group, the r-RBA has been widely used as a means to characterize the mode of action and as detection method in various biological matrices. Yet, screening methods have not been standardized, and the details of the ciguatoxin-specific r-RBA are not well documented, which limit interlaboratory comparison and progress toward method validation. This work presents the development of an optimized r-RBA for ciguatoxins and provides guidance on its use and quality control checks for analysis of environmental samples. We focus on the analysis of critical parameters involved in determining assay acceptability. Calculation of toxin concentrations in fish samples is illustrated with four examples. Thus, this paper provides the detailed information required for a full validation of the r-RBA, a necessary step toward the development and implementation of a regulatory monitoring programme for ciguatoxins in seafood products using the r-RBA.
引用
收藏
页码:289 / 294
页数:6
相关论文
共 50 条
  • [1] A rapid bead-based radioligand binding assay for the determination of target-binding fraction and quality control of radiopharmaceuticals
    Sharma, Sai Kiran
    Lyashchenko, Serge K.
    Park, Hijin A.
    Pillarsetty, Nagavarakishore
    Roux, Yorann
    Wu, Jiong
    Poty, Sophie
    Tully, Kathryn M.
    Poirier, John T.
    Lewis, Jason S.
    NUCLEAR MEDICINE AND BIOLOGY, 2019, 71 : 32 - 38
  • [2] IMMUNOPRECIPITATION METHOD FOR A RADIOLIGAND BINDING ASSAY OF EPIDERMAL GROWTH-FACTOR RECEPTOR
    DITTADI, R
    GION, M
    BRAZZALE, A
    BRUSCAGNIN, G
    JOURNAL OF NUCLEAR MEDICINE AND ALLIED SCIENCES, 1990, 34 (04): : 225 - 230
  • [3] DEVELOPMENT OF A RADIOLIGAND RECEPTOR-BINDING ASSAY FOR MEASUREMENT OF NEUROLEPTIC DRUGS IN SERUM
    EPPERLY, M
    NEWMAN, DC
    HOMBURGER, HA
    CLINICAL RESEARCH, 1983, 31 (04): : A716 - A716
  • [4] ESTROGEN-RECEPTOR DETERMINATION WITH MONOCLONAL-ANTIBODIES - CORRELATION WITH RADIOLIGAND BINDING ASSAY
    PIFFANELLI, A
    PELIZZOLA, D
    GIOVANNINI, G
    SCAGLIANTI, G
    JOURNAL OF NUCLEAR MEDICINE AND ALLIED SCIENCES, 1985, 29 (1-2): : 131 - 131
  • [5] DOUBLE ISOTOPE RADIOLIGAND RECEPTOR ASSAY METHOD FOR DETERMINATION OF SPECIFIC ACTIVITY OF RECEPTOR ACTIVE HCG
    COLE, FE
    RICE, BF
    FEDERATION PROCEEDINGS, 1974, 33 (03) : 204 - 204
  • [6] DEVELOPMENT OF A RADIOLIGAND BINDING ASSAY FOR THE 5-HT(4)-RECEPTOR - USE OF A NOVEL ANTAGONIST
    GROSSMAN, CJ
    GALE, JD
    BUNCE, KT
    KILPATRICK, GJ
    WHITEHEAD, JWF
    OXFORD, AW
    HUMPHREY, PPA
    BRITISH JOURNAL OF PHARMACOLOGY, 1993, 108 : P106 - P106
  • [7] RADIOLIGAND BINDING ASSAY VERSUS IMMUNOENZYMATIC TECHNIQUE FOR STEROID-RECEPTOR DETERMINATION IN MAMMARY-CANCER
    PIFFANELLI, A
    GIOVANNINI, G
    BOZZETTI, C
    NALDI, N
    RICCOBON, A
    ZOLI, W
    DITTADI, R
    GION, M
    QUERCIOLI, M
    MESSERI, G
    CATOZZI, L
    FAGGIOLI, L
    PELIZZOLA, D
    GIGANTI, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1988, 14 (5-6): : 314 - 314
  • [8] Development and Validation of HPLC Method for DAAF and its Applications in Quality Control and Environmental Monitoring
    Chen, Jian-Bo
    Ding, Huan
    Li, Jianjun
    Chen, Ya
    Liu, Yu
    Zhao, Xueyan
    PROPELLANTS EXPLOSIVES PYROTECHNICS, 2020, 45 (10) : 1580 - 1589
  • [9] Method development and quality assurance for the analysis of hydrocarbons in environmental samples
    Morel, G
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1996, 63 (04) : 269 - 288
  • [10] Method development and quality assurance for the analysis of hydrocarbons in environmental samples
    Water Quality Institute , Agern Allé 11, DK-2970 Hørsholm, Denmark
    INT. J. ENVIRON. ANAL. CHEM., 4 (269-288):