Magnetic Metal-Organic Framework/Graphene Oxide-Based Solid-Phase Extraction Combined with Spectrofluorimetry for the Determination of Enrofloxacin in Milk Sample

被引:15
|
作者
Li, Zhaoqian [1 ]
Qi, Mengyu [1 ]
Tu, Chunyan [1 ]
Wang, Weiping [1 ]
Chen, Jianrong [2 ]
Wang, Ai-Jun [2 ]
机构
[1] Zhejiang Normal Univ, Coll Chem & Life Sci, Jinhua 321004, Peoples R China
[2] Zhejiang Normal Univ, Coll Geog & Environm Sci, Jinhua 321004, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic metal-organic framework/graphene oxide (Fe3O4/MIL-100(Fe)/GO); Magnetic solid-phase extraction; Enrofloxacin; Spectrofluorimetry; Milk sample; PERFORMANCE LIQUID-CHROMATOGRAPHY; POLYCYCLIC AROMATIC-HYDROCARBONS; FACILE SYNTHESIS; SELECTIVE EXTRACTION; WATER; GRAPHENE; FLUOROQUINOLONES; FABRICATION; SORBENT; ENRICHMENT;
D O I
10.1007/s12161-017-0971-6
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
We have developed an analytical method for the extraction and determination of enrofloxacin in milk sample by magnetic solid-phase extraction with metal-organic framework/graphene oxide (Fe3O4/MIL-100(Fe)/GO) as a sorbent coupling to spectrofluorimetry. The prepared Fe3O4/MIL-100(Fe)/GO nanocomposite were characterized by scanning electron microscopy, FT-IR spectroscopy, x-ray diffraction, and vibration sample magnetometer. The parameters affecting extraction efficiency including sample pH, amounts of sorbent, adsorption time, and acidity of elution solvent were optimized systematically. The optimal extraction conditions were as follows: 100.0-mL sample at pH of 8.0, 20.0 mg of Fe3O4/MIL-100(Fe)/GO as sorbent, extraction time of 30 min, and 4.00 mL of 15% (v/v) formic acid in methanol as eluent. A matrix-matched linear relationship (10.00-350.00 mu g L-1) between the fluorescence intensity and the concentrations of enrofloxacin was obtained with correlation coefficient (r) = 0.9979. The limit of detection (S/N = 3) and the limit of quantification (S/N = 10) were 0.65 and 2.17 mu g L-1, respectively. The relative standard deviations of intraday and interday analysis (n = 5) were 1.64 and 2.86%, respectively. The proposed method was successfully applied for the determination of enrofloxacin in milk sample with recoveries ranged from 85.7 to 106.3%.
引用
收藏
页码:4094 / 4103
页数:10
相关论文
共 50 条
  • [1] Magnetic Metal-Organic Framework/Graphene Oxide-Based Solid-Phase Extraction Combined with Spectrofluorimetry for the Determination of Enrofloxacin in Milk Sample
    Zhaoqian Li
    Mengyu Qi
    Chunyan Tu
    Weiping Wang
    Jianrong Chen
    Ai-Jun Wang
    Food Analytical Methods, 2017, 10 : 4094 - 4103
  • [2] Determination of diuretics in human urine using HPLC coupled with magnetic solid-phase extraction based on a metal-organic framework
    Liu, Meng
    Lv, Bingqiang
    Jiang, Hailong
    Yuan, Pei
    Zhu, Huan
    Gao, Binghong
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (09)
  • [3] Magnetic Solid-Phase Extraction of Organic Compounds Based on Graphene Oxide Nanocomposites
    Manousi, Natalia
    Rosenberg, Erwin
    Deliyanni, Eleni
    Zachariadis, George A.
    Samanidou, Victoria
    MOLECULES, 2020, 25 (05):
  • [4] Metal-organic framework derived magnetic nanoporous carbon as an adsorbent for the magnetic solid-phase extraction of chlorophenols from mushroom sample
    Hao, Lin
    Liu, Xing-Li
    Wang, Jun-Tao
    Wang, Chun
    Wu, Qiu-Hua
    Wang, Zhi
    CHINESE CHEMICAL LETTERS, 2016, 27 (05) : 783 - 788
  • [5] Metal-organic framework derived magnetic nanoporous carbon as an adsorbent for the magnetic solid-phase extraction of chlorophenols from mushroom sample
    Lin Hao
    Xing-Li Liu
    Jun-Tao Wang
    Chun Wang
    Qiu-Hua Wu
    Zhi Wang
    ChineseChemicalLetters, 2016, 27 (05) : 783 - 788
  • [6] Determination of Enantiomeric Excess by Solid-Phase Extraction Using a Chiral Metal-Organic Framework as Sorbent
    Zhang, Jun-Hui
    Tang, Bo
    Xie, Sheng-Ming
    Wang, Bang-Jin
    Zhang, Mei
    Chen, Xing-Lian
    Zi, Min
    Yuan, Li-Ming
    MOLECULES, 2018, 23 (11):
  • [7] A magnetic metal-organic framework as a new sorbent for solid-phase extraction of copper(II), and its determination by electrothermal AAS
    Wang, Yang
    Xie, Jing
    Wu, Yichun
    Hu, Xiaoya
    MICROCHIMICA ACTA, 2014, 181 (9-10) : 949 - 956
  • [8] A magnetic metal-organic framework as a new sorbent for solid-phase extraction of copper(II), and its determination by electrothermal AAS
    Yang Wang
    Jing Xie
    Yichun Wu
    Xiaoya Hu
    Microchimica Acta, 2014, 181 : 949 - 956
  • [9] Magnetic solid-phase extraction based on graphene oxide for the determination of lignans in sesame oil
    Wu, Linxia
    Yu, Li
    Ding, Xiaoxia
    Li, Peiwu
    Dai, Xianhong
    Chen, Xiaomei
    Zhou, Haiyan
    Bai, Yizhen
    Ding, Jian
    FOOD CHEMISTRY, 2017, 217 : 320 - 325
  • [10] Rapid Determination of Trace Sulfonamides in Milk by Graphene Oxide-Based Magnetic Solid Phase Extraction Coupled with HPLC–MS/MS
    Yutang Wang
    Laping Liu
    Chunxia Xiao
    Lin Chen
    Peng Yang
    Qian Liu
    Jianlong Wang
    Xuebo Liu
    Food Analytical Methods, 2016, 9 : 2521 - 2530