Pull-out tests in presence of high level of corrosion

被引:0
|
作者
Mancini, G. [1 ]
Sabia, D. [1 ]
Pettinato, E. [1 ]
Tondolo, F. [1 ]
机构
[1] Politecn Torino, Dept Struct Geotech & Bldg Engn, I-10129 Turin, Italy
关键词
REINFORCEMENT; CONCRETE; BOND;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Bond between steel and concrete deeply influences the structural behaviour of reinforced concrete structures. In the present work, local bond-slip behaviour is analysed in presence of corrosion of reinforcing bar embedded in concrete. The results of the tests on concrete cubes with side of 120 mm reinforced with ribbed steel bars with diameter of 12 mm with and without confinement in presence of an increasing level of corrosion up to 10% of estimated mass loss are presented. A Rilem pull-out test type is employed; therefore the analysis arises the local relationship between steel and concrete because of the short embedment length. Corrosion is applied by means of electrochemical procedure. Results showed the influence of corrosion level and the presence of confinement in the terms of bond efficiency.
引用
收藏
页码:2120 / 2125
页数:6
相关论文
共 50 条
  • [1] EFFECT OF ADMIXTURES ON REINFORCED CONCRETE CORROSION ASSESSED THROUGH PULL-OUT TESTS
    Neves, Rui
    Vicente, Cilene
    Castela, Antonio
    Duarte, Raquel
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON MECHANICS AND MATERIALS IN DESIGN (M2D2017), 2017, : 935 - 936
  • [2] COMPARISON OF MATERIALS FOR STAPLE PULL-OUT TESTS
    THOMAS, AMC
    PYNSENT, PB
    MCCOMBE, PF
    JOURNAL OF TESTING AND EVALUATION, 1992, 20 (03) : 233 - 236
  • [3] Load transfer mechanism in pull-out tests
    Alobaidi, IM
    Hoare, DJ
    Ghataora, GS
    GEOSYNTHETICS INTERNATIONAL, 1997, 4 (05) : 509 - 521
  • [4] Pull-out tests on handcrafted headed studs
    Carvalho de Oliveira, Denio Ramam
    de Oliveira, Andrielli Morais
    da Costa, Viviane Gatti
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2019, 172 (09) : 625 - 631
  • [5] Pull-out tests on RC corroded specimens
    Cesetti, A.
    Mancini, G.
    Tondolo, F.
    CONCRETE REPAIR, REHABILITATION AND RETROFITTING IV, 2016, : 27 - 27
  • [6] Analytical simulation of pull-out tests - the direct problem
    Banholzer, B
    Brameshuber, W
    Jung, W
    CEMENT & CONCRETE COMPOSITES, 2005, 27 (01): : 93 - 101
  • [7] Analytical evaluation of pull-out tests - The inverse problem
    Banholzer, B.
    Brameshuber, W.
    Jung, W.
    CEMENT & CONCRETE COMPOSITES, 2006, 28 (06): : 564 - 571
  • [8] A theoretical model for anchored geosynthetics in pull-out tests
    Gurung, N
    GEOSYNTHETICS INTERNATIONAL, 2000, 7 (03) : 269 - 284
  • [9] Pull-out tests for bond strengths of geopolymer concretes
    Rajamane, N.P., 1600, Associated Cement Companies Ltd. (86):
  • [10] Bearing force mobilisation in pull-out tests on geogrids
    Palmeira, EM
    GEOTEXTILES AND GEOMEMBRANES, 2004, 22 (06) : 481 - 509