Flexor Tendon Irritations after Locked Plate Fixation of the Distal Radius with the 3.5 mm T-Plate: Identification of Risk Factors

被引:14
|
作者
Ateschrang, A. [1 ]
Stuby, F. [1 ]
Werdin, F. [1 ]
Schaller, H. -E. [1 ]
Weise, K. [1 ]
Albrecht, D. [1 ]
机构
[1] Berufsgenossenschaftliche Unfallklin Tubingen, D-72076 Tubingen, Germany
来源
关键词
distal radius fracture; volar locked plate; flexor tendon irritation; watershed line; PALMAR LOCKING-PLATE; DORSALLY DISPLACED FRACTURES; OSTEOSYNTHESIS; COMPLICATIONS; SYSTEM; WRIST;
D O I
10.1055/s-0029-1241027
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim: Volar locked plate fixation of distal radius fractures has become an established procedure in the past decade, although reports of flexor tendon injuries due to volar plating have been increasing. The aim of the present study is to identify the risk factors which produce irritations of flexor tendons using the locking palmar 3.5 mm T-plate, with special emphasis placed on the watershed line and the pronator quadratus muscle. Method: In this retrospective study, all patients with distal radius fractures who had been treated with a locking volar 3.5 mm T-plate between 2001 and 2005 were evaluated. The X-ray controls were analysed with regard to secondary losses of reduction, bony healing disturbances and the topographic relation to the watershed line. Follow-up included a clinical and subjective assessment using the DASH score. All patients underwent sonography to identify irritations of the tendons under functional conditions (neural and dorsal wrist flexion). Results: A total of 151 patients were treated with the locked volar 3.5 mm T-plate. Of these, 68 patients could be included for follow-up. The mean age was 47.8 years with a mean follow-up period of 3.5 years. Fracture classification according to the AO indicated 13 A, 14 B and 41 C fractures with 37 Colles and 31 Smith fractures. Fracture union was achieved in all patients. A mean palmar tilt of 2.8 degrees (range: 1 to 9 degrees) was observed, with a loss of reduction in three cases of about 5 degrees. There were no implant failures. The mean DASH score was 12. The watershed line was reached by the distal edge of the plate in 48 patients and was exceeded in 20 cases. In 30 patients the pronator quadratus muscle could not be identified. In the remaining 38 cases the mean diameter was reduced to 1.4 mm, while the unaffected contralateral muscle had a mean diameter of 3.8 mm (range: 2.8 to 7 mm). Irritations of flexor tendons occurred only in 4 cases, in those patients where the pronator quadratus muscle could not be identified (2 tendon erosions and 2 tenosynovitises; 5.9%). Relevant functional distal plate prominence was detected in dorsal flexion (power grip) in 3 cases (4.4%), producing tendon deflection. The topographic relation of the plate to the watershed line played a minor role in causing tendon irritations, in contrast to the muscular coverage of the distal plate. Plate coverage by a vital reconstructed pronator quadratus muscle produces a greater distance of the tendon compartment to the plate, whereas a complete muscular coverage of the distal plate edge is difficult to realise, although it is not necessary regarding functional conditions. Conclusion: Stabilisation of distal radius fractures with dorsal and volar displacement by the locked palmar 3.5 mm T-plate produces positive results. A careful reconstruction of the pronator quadratus is more important than respecting the watershed line in that it achieves muscular coverage, and thus provides a greater distance of the plate to the tendon compartment. We recommend sonography after bony healing to identify functional plate prominence or tendon irritations under functional conditions (dorsal wrist flexion) and, if necessary, plate removal. Further systematic sonographic examinations should be undertaken including other locked plate systems.
引用
收藏
页码:319 / 325
页数:7
相关论文
共 50 条
  • [1] Is the locking, 3.5 mm palmar T-plate the implant of choice for displaced distal radius fractures?
    Strohm, P. C.
    Mueller, C. A.
    Helwig, P.
    Mohr, B.
    Suedkamp, N. P.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2007, 145 (03): : 331 - 337
  • [2] Fracture of the Distal Radius: Risk Factors for Complications After Locked Volar Plate Fixation
    Soong, Maximillian
    van Leerdam, Roderick
    Guitton, Thierry G.
    Got, Christopher
    Katarincic, Julia
    Ring, David
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (01): : 3 - 9
  • [3] Flexor tendon repair after rupture caused by volar plate fixation of the distal radius
    Rubensson, Carin C.
    Ydreborg, Karin
    Boren, Linda
    Karlander, Lars-Erik
    JOURNAL OF PLASTIC SURGERY AND HAND SURGERY, 2015, 49 (02) : 112 - 115
  • [4] FLEXOR POLLICIS LONGUS TENDON RUPTURES AFTER PALMAR PLATE FIXATION OF FRACTURES OF THE DISTAL RADIUS
    Casaletto, J. A.
    Machin, D.
    Leung, R.
    Brown, D. J.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2009, 34E (04) : 471 - 474
  • [5] OSTEOSYNTHESIS OF DISTAL RADIUS FRACTURES WITH A T-PLATE
    RAHMANZADEH, R
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1990, : 657 - 661
  • [6] PREVENTION OF FLEXOR POLLICIS LONGUS TENDON RUPTURE AFTER VOLAR PLATE FIXATION OF DISTAL RADIUS FRACTURES
    Tada, Kaoru
    Ikeda, Kazuo
    Shigemoto, Kenji
    Suganuma, Seigo
    Tsuchiya, Hiroyuki
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2011, 16 (03): : 271 - 275
  • [7] Predicting Flexor Tendon Complications Following Volar Plate Fixation of Distal Radius Fractures
    Yang, J.
    Parkes, R.
    Yip, C. R.
    Chojnowski, A.
    BRITISH JOURNAL OF SURGERY, 2024, 111
  • [8] Volar Plate Position and Flexor Tendon Rupture Following Distal Radius Fracture Fixation
    Kitay, Alison
    Swanstrom, Morgan
    Schreiber, Joseph J.
    Carlson, Michelle G.
    Nguyen, Joseph T.
    Weiland, Andrew J.
    Daluiski, Aaron
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (06): : 1091 - 1096
  • [9] A biomechanical comparison of a dorsal 3.5-mm T-plate and a volar fixed-angle plate in a model of dorsally unstable distal radius fractures
    Liporace, FA
    Gupta, S
    Jeong, GK
    Stracher, M
    Kummer, F
    Egol, KA
    Koval, KJ
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (03) : 187 - 191
  • [10] Reducing the risk of flexor pollicis longus tendon rupture after volar plate fixation for distal radius fractures: validation of the tendon irritation test
    Suganuma S.
    Tada K.
    Tsuchiya H.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (8) : 1425 - 1429