Reproducibility of black-blood coronary vessel wall MR imaging

被引:21
|
作者
Hazirolan, T
Gupta, SN
Mohamed, MA
Bluemke, DA
机构
[1] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[2] GE Healthcare, Appl Sci Lab, Baltimore, MD USA
关键词
vessel wall imaging; coronary MRA; black blood imaging; reproducibility;
D O I
10.1081/JCMR-200053464
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose. New magnetic resonance imaging (MRI) methods can provide high spatial resolution images of the coronary artery wall, and statistically significant differences in coronary vessel wall thickness between atherosclerotic disease patients and control subjects have been shown. The aim of this study is to assess inter-study reproducibility (i.e., repeatability) of the cross-sectional 2D coronary vessel wall MRI using a black-blood technique. Methods and Results. Twelve healthy adult subjects were studied with the use of a commercial 1.5 T CMR system. A double inversion recovery fast spin-echo (FSE) sequence ( black blood) was used. Each subject was scanned twice on different days. The mean RCA lumen area difference between study 1 and study 2 was 0.004 mm(2), and the coefficient of repeatability ( COR) was +/- 0.06 mm(2). The mean RCA wall thickness difference between study 1 and study 2 was 0.02 mm, and the COR was +/- 0.39 mm. Conclusion. Cross-sectional coronary vessel wall imaging with 2D double-IR FSE is highly reproducible for serial evaluation of coronary vessel walls and atherosclerotic coronary artery disease.
引用
收藏
页码:409 / 413
页数:5
相关论文
共 50 条
  • [1] Phase-sensitive black-blood coronary vessel wall imaging
    Khaled Z Abd-Elmoniem
    Matthias Stuber
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [2] Phase-Sensitive Black-Blood Coronary Vessel Wall Imaging
    Abd-Emoniem, Khaled Z.
    Weiss, Robert G.
    Stuber, Matthias
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (04) : 1021 - 1030
  • [3] Rapid extended coverage simultaneous multisection black-blood vessel wall MR imaging
    Mani, V
    Itskovich, VV
    Szimtenings, M
    Aguinaldo, JGS
    Samber, DD
    Mizsei, G
    Fayad, ZA
    RADIOLOGY, 2004, 232 (01) : 281 - 288
  • [4] Three-dimensional black-blood magnetic resonance coronary vessel wall imaging
    Kim, WY
    Botnar, RM
    Stuber, M
    Börnert, P
    Manning, WJ
    CIRCULATION, 2001, 104 (17) : 375 - 375
  • [5] DANTE preparation for black-blood coronary wall imaging
    Meihan Wang
    Christopher M Kramer
    Craig H Meyer
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [6] Relaxation enhanced compressed sensing three-dimensional black-blood vessel wall MR imaging: Preliminary studies
    Li, Bo
    Li, Hao
    Li, Jun
    Zhang, Yuchen
    Wang, Xiaoying
    Zhang, Jue
    Dong, Li
    Fang, Jing
    MAGNETIC RESONANCE IMAGING, 2015, 33 (07) : 932 - 938
  • [7] Reproducibility of coronary vessel wall imaging techniques
    Scott A.D.
    Keegan J.
    Firmin D.N.
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [8] Closed contour edge detection of blood vessel lumen and outer wall boundaries in black-blood MR images
    Yuan, C
    Lin, E
    Millard, J
    Hwang, JN
    MAGNETIC RESONANCE IMAGING, 1999, 17 (02) : 257 - 266
  • [9] Measurements of blood vessel wall areas in black-blood MR images using global minimum snake algorithm
    Lin, E
    Hwang, JN
    Yuan, C
    ICASSP '99: 1999 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, PROCEEDINGS VOLS I-VI, 1999, : 3409 - 3412
  • [10] Measurements of blood vessel wall areas in black-blood MR images using global minimum snake algorithm
    Lin, Eugene
    Hwang, Jenq-Neng
    Yuan, Chun
    ICASSP, IEEE International Conference on Acoustics, Speech and Signal Processing - Proceedings, 1999, 6 : 3409 - 3412