"Low Dose MR" Dixon Technique for Imaging FDG PET-MR Lymphoma

被引:1
|
作者
Mufti, Musa Ali [1 ]
Matthews, Robert [2 ]
Madu, Ezemonye [3 ]
Yaddanapudi, Kavitha [4 ]
Franceschi, Dinko [2 ]
机构
[1] Stonybrook Univ Hosp, Dept Radiol, New York, NY 11794 USA
[2] Stony Brook Univ Hosp, Dept Nucl Med, New York, NY USA
[3] Hofstra Northwell, Sch Med, New York, NY USA
[4] Coll Med, Dept Med Imaging, Tucson, AZ USA
关键词
Keywords; Dixon sequence; PET-MR; lymphoma; FDG; multi-sequence MR; RESPONSE ASSESSMENT; HODGKIN; PET/MRI;
D O I
10.1055/s-0042-1750330
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction Hybrid PET-MR is a relatively new imaging modality with its major strength being the MR component offering superior soft tissue contrast. While PET/MRI offers the inherent advantage of reduced radiation dose, it has been shown to result in a markedly prolonged examination time becoming a challenge in children and sick patients. "Low dose MRI" is a term used in the nuclear medicine community to describe fast acquired PET-MR scan protocols that rely heavily on PET images for diagnosis. In this study, we sought to determine if the Dixon sequences obtained for attenuation correction could be used as a diagnostic sequence for interpreting PET-MRI lymphoma cases, potentially reducing scan time. Materials and Methods We retrospectively identified 40 patients who underwent (88) FDG PET-MR body imaging studies for staging or restaging lymphoma. A radiologist and nuclear medicine physician initially reviewed top of the head to mid thigh PET images, attenuation correction coronal Dixon MRI sequences, and PET-MR fusion with Dixon sequence. The same physicians reviewed the PET images, multi-sequence MR including the attenuation correction Dixon, and multi-sequence PET-MR fusion images The lesions were further characterized based on their imaging characteristics, size, SUVmax, and malignant potency. A consensus read followed. Results All patients were adults with an average study age of 43.8 years. Our study consisted of 40 females and 48 males out of which 7 were for staging and 81 were for re-staging. All patients had systemic lymphoma. Thirty-seven of the studies had active lymph nodes on Dixon PET-MR that agreed with multi-sequence PET-MR which identified 33 positive cases (89.1%) having an average SUV 10.2 +/- 7.74 SD. Four Dixon PET-MR cases did not detect lesions, with an average SUV 2.3 +/- 0.55 SD, which was read as minimal residual activity. Multi-sequence MR identified 11 patients with enlarged lymph nodes without FDG uptake, which were not seen on Dixon MR. All 5 studies with bones lesions were detected by Dixon PET-MR as well as 2 soft tissue organ lesions. Multi-sequence MR identified 1 patient with non-active, healed bone lesion. Fifty-five of these studies were true negatives. Compared to multi-sequence PET-MR, Dixon PET-MR demonstrated 89.2% sensitivity, 100% specificity with no false positive studies. Conclusion The present study investigated the diagnostic potential of a fast protocol for integrated PET/MRI used for dedicated tumor staging of patients with lymphoma. In this retrospective study, Dixon PET-MR was shown to be sensitive and specific compared to multi-sequence PET-MR in the detection of lymphoma. The low number of these cases not detected had minimally active lymph nodes that resolved on subsequent imaging and probably were not clinically important.
引用
收藏
页码:99 / 105
页数:7
相关论文
共 50 条
  • [1] Quantitative Simultaneous PET-MR Imaging
    Ouyang, Jinsong
    Petibon, Yoann
    Huang, Chuan
    Reese, Timothy G.
    Kolnick, Aleksandra L.
    El Fakhri, Georges
    MICRO- AND NANOTECHNOLOGY SENSORS, SYSTEMS, AND APPLICATIONS VI, 2014, 9083
  • [3] PET-MR Imaging in Head and Neck
    Lee, Yueh Z.
    Ramaiho, Joana
    Kessler, Brice
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2017, 25 (02) : 315 - +
  • [4] Imaging of Osteoarthritis by Conventional Radiography, MR Imaging, PET-Computed Tomography, and PET-MR Imaging
    Hayashi, Daichi
    Roemer, Frank W.
    Guermazi, Ali
    PET CLINICS, 2019, 14 (01) : 17 - +
  • [5] MOLECULAR IMAGING WITH PET-CT AND PET-MR
    Beuthien-Baumann, B.
    RADIOTHERAPY AND ONCOLOGY, 2012, 104 : 27 - 27
  • [6] Time to move to PET-MR for cardiovascular imaging
    Lairez, Olivier
    Robson, Philip M.
    Fayad, Zahi A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2016, 23 (05) : 1112 - 1113
  • [7] Time to move to PET-MR for cardiovascular imaging
    Olivier Lairez
    Philip M. Robson
    Zahi A. Fayad
    Journal of Nuclear Cardiology, 2016, 23 : 1112 - 1113
  • [8] Applications of PET-MR Imaging in Cardiovascular Disorders
    Cardoso, Rhanderson
    Leucker, Thorsten M.
    PET CLINICS, 2020, 15 (04) : 509 - 520
  • [9] Transmission imaging for integrated PET-MR systems
    Bowen, Spencer L.
    Fuin, Niccolo
    Levine, Michael A.
    Catana, Ciprian
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (15): : 5547 - 5568
  • [10] Simultaneously acquired FDG PET-MR body imaging in the detection of breast cancer metastases
    Franceschi, Ana
    Matthews, Robert
    Chimpiri, A. Rao
    Relan, Nand
    Yaddanapudi, Kavitha
    Franceschi, Dinko
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57