Validation of three-dimensional laser scanning for the assessment of facial fat changes

被引:4
|
作者
Paton, Nicholas I.
Yang, Y.
Sitoh, Y-Y
Tha, Naing Oo
机构
[1] MRC, Clin Trials Unit, London NW1 2DA, England
[2] Tan Tock Seng Hosp, Dept Infect Dis, Singapore, Singapore
[3] Natl Inst Neurosci, Dept Neuroradiol, Singapore, Singapore
关键词
accuracy; fat; HIV; laser scanning; lipoatrophy; magnetic resonance imaging; reproducibility;
D O I
10.1111/j.1468-1293.2007.00501.x
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Objective We aimed to evaluate the accuracy of three-dimensional laser scanning as an objective method for detecting facial changes. Methods Facial laser scanning was performed at baseline and repeated after a median of 10 months in 24 HIV-infected patients, 12 with ongoing lipodystrophy, five with > 10% weight loss and seven with > 10% weight gain. Surface volume change was estimated using a standardized technique, and compared with change in cheek fat measured by magnetic resonance imaging (MRI). Results The median laser scanning surface volume changes were -2.1 (range -4.6 to -0.8) mL in the lipoatrophy group, -1.5 (range -6.8 to -1.3) mL in the weight loss group and +3.1 (range -0.2 to +5.4) mL in the weight gain group (the median MRI cheek fat changes were -4.6, -3.7 and +7.0 mL in the three groups, respectively). Laser scanning and MRI measurements were not significantly associated in lipoatrophy patients (r=0.34, P=0.28), but there was a good association in patients who changed weight (r=0.71, P=0.01). Conclusions Laser scanning detects changes in the appropriate direction, although it underestimates MRI-measured cheek fat changes. Laser scanning may be useful as an objective measure of cheek surface volume changes, but needs further validation in larger clinical cohorts.
引用
收藏
页码:498 / 503
页数:6
相关论文
共 50 条
  • [1] Assessment of facial asymmetry in growing subjects with a three-dimensional laser scanning system
    Primozic, J.
    Perinetti, G.
    Zhurov, A.
    Richmond, S.
    Ovsenik, M.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2012, 15 (04) : 237 - 244
  • [2] Assessment of facial tissue expansion with three-dimensional digitizer scanning
    Ji, Y
    Zhang, F
    Schwartz, J
    Stile, F
    Lineaweaver, WC
    JOURNAL OF CRANIOFACIAL SURGERY, 2002, 13 (05) : 687 - 692
  • [3] Facial asymmetry: Three-dimensional analysis using laser surface scanning
    O'Grady, KF
    Antonyshyn, OM
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 104 (04) : 928 - 937
  • [4] Validation of a three-dimensional facial scanning system based on structured light techniques
    Ma, Lili
    Xu, Tianmin
    Lin, Jiuxiang
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2009, 94 (03) : 290 - 298
  • [5] Three-dimensional quantification of facial symmetry in adolescents using laser surface scanning
    Djordjevic, Jelena
    Toma, Arshed M.
    Zhurov, Alexei I.
    Richmond, Stephen
    EUROPEAN JOURNAL OF ORTHODONTICS, 2014, 36 (02) : 125 - 132
  • [6] Three-dimensional facial anthropometry using a laser surface scanner: Validation of the technique
    Bush, K
    Antonyshyn, O
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1996, 98 (02) : 226 - 235
  • [7] Validation of a low-cost laser scanner device for the assessment of three-dimensional facial anatomy in living subjects
    Gibelli, Daniele
    Pucciarelli, Valentina
    Caplova, Zuzana
    Cappella, Annalisa
    Dolci, Claudia
    Cattaneo, Cristina
    Sforza, Chiarella
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (09) : 1493 - 1499
  • [8] Three-dimensional analysis of facial shape and symmetry in twins using laser surface scanning
    Djordjevic, J.
    Jadallah, M.
    Zhurov, A. I.
    Toma, A. M.
    Richmond, S.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2013, 16 (03) : 146 - 160
  • [9] Three-dimensional Assessment of the Breast: Validation of a Novel, Simple and Inexpensive Scanning Process
    Oranges, Carlo M.
    Madduri, Srinivas
    Brantner, Philipp
    Msallem, Bilal
    Giordano, Salvatore
    Benitez, Benito
    Kalbermatten, Daniel F.
    Schaefer, Dirk J.
    Thieringer, Florian M.
    IN VIVO, 2019, 33 (03): : 839 - 842
  • [10] Three-dimensional Laser Surface Scanning in Rhinosurgery
    Largo, Rene D.
    Wettstein, Reto
    Fulco, Ilario
    Tremp, Mathias
    Schaefer, Dirk J.
    Gubisch, Wolfgang
    Haug, Martin D.
    FACIAL PLASTIC SURGERY, 2013, 29 (02) : 116 - 120