Overall chilled water system energy consumption modeling and optimization

被引:27
|
作者
Trautman, Neal [1 ]
Razban, Ali [1 ]
Chen, Jie [1 ]
机构
[1] Indiana Univ Purdue Univ, Dept Mech & Energy Engn, Indianapolis, IN 46202 USA
基金
美国能源部;
关键词
Chilled water system; Variable speed drive; Condenser water system; Cooling tower; HVAC optimization; PERFORMANCE; SPEED; PLANT;
D O I
10.1016/j.apenergy.2021.117166
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The emergence of increasingly affordable variable-speed drive technology has changed the approach used to control chilled water systems equipped with these drives. The purpose of this research was to develop an integrated chilled water modeling technique that can determine the optimal system setpoints and estimate the energy saving potential of chiller system. The chiller system equipped with Variable Frequency Drives (VFDs) on cooling tower fans and condenser water pumps. To accomplish the objective, physical component models of the centrifugal chiller, cooling tower and condenser water pump were established with the goal of incorporating the system's condenser water flow rate and cooling tower fan speeds as optimization variables. Furthermore, a cooling load prediction algorithm was developed using a multiple non-linear regression model to approximate the building's cooling load subject to a range of environmental conditions. The inputs and outputs of the individual component models were linked to estimate how adjusting the cooling tower fan and condenser water pump speed would influence the system's comprehensive performance. The overall system model was then optimized using a generalized reduced gradient optimization algorithm to determine the potential energy savings through speed control with VFDs and to ascertain a control logic strategy for the building automation system to operate the heating and cooling system. A case-study was performed on a single chiller system at a museum and the model was calibrated according to logged data collected over four months. Results showed that for the system analyzed, the energy saving of optimizing the cooling tower fan system was found to be 12-15%, while the energy saving potential of optimizing the condenser water pump with the cooling tower fan was negligible. Additionally, comparing different cooling tower fan control strategies showed that a wet-bulb approach-based cooling tower control strategy was shown to have the highest correlation to the optimized fan speed with an R2 of 0.924.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] The Energy Consumption Calculation of the Fan Coil Chilled Water System Based on Variable Chilled Water Temperature and Flux
    Wang, Gang
    ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 651 - 655
  • [2] Dynamic optimization of chilled water pump operation to reduce HVAC energy consumption
    Wijaya, Timotius Kelvin
    Sholahudin, M. Idrus
    Alhamid, M. Idrus
    Saito, Kiyoshi
    Nasruddin, N.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2022, 36
  • [3] CHILLED WATER-SYSTEM OPTIMIZATION
    AUSTIN, SB
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1993, 35 (07): : 50 - 56
  • [4] A simulation-optimization approach for energy efficiency of chilled water system
    Lee, Kuei-Peng
    Cheng, Te-Ang
    ENERGY AND BUILDINGS, 2012, 54 : 290 - 296
  • [5] Central chilled water system modeling
    Kirby, Nelson
    Engineered Systems, 2010, 27 (03):
  • [6] Energy Saving Optimization of Chilled Water System Based on Improved Fruit Fly Optimization Algorithm
    Feng, Zengxi
    Wang, Wenjing
    He, Xin
    Li, Gangting
    Zhang, Lutong
    Xiang, Weipeng
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2023, 15 (08)
  • [7] Energy analysis of chilled water system configurations using simulation-based optimization
    Ali, Muzaffar
    Vukovic, Vladimir
    Sahir, Mukhtar Hussain
    Fontanella, Giuliano
    ENERGY AND BUILDINGS, 2013, 59 : 111 - 122
  • [8] Modeling and optimization for the smart operation of a central chilled water system in a high-rise building
    Wang, Hai
    Meng, Hua
    Ju, Ran
    Xue, Feng
    Li, Ting
    4TH ASIA CONFERENCE OF INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2019, 238
  • [9] Modeling and optimization for piercing energy consumption
    Dong Xiao
    Xiao-li Pan
    Yong Yuan
    Zhi-zhong Mao
    Fu-li Wang
    Journal of Iron and Steel Research International, 2009, 16 : 40 - 44
  • [10] Modeling and optimization of HVAC energy consumption
    Kusiak, Andrew
    Li, Mingyang
    Tang, Fan
    APPLIED ENERGY, 2010, 87 (10) : 3092 - 3102