Quality Factor Enhancement Technology of Laser Doppler Signal Based on Liquid Lens

被引:5
|
作者
Xi Chongbin [1 ]
Huang Rong [1 ]
Zhou Jian [1 ]
Nie Xiaoming [1 ]
机构
[1] Natl Univ Def Technol, Coll Adv Interdisciplinary Studies, Changsha 410073, Hunan, Peoples R China
来源
关键词
measurement; laser Doppler velocimeter; quality factor; liquid lens; driving current; working distance; measurable range;
D O I
10.3788/CJL202148.0704003
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Objective A laser Doppler velocimeter (LDV) obtains the moving velocities of carriers by gauging the interference signal when the signal light is mixed with a reference. As a novel speed sensor, LDV possesses several advantages: non-contact measurement, no interference with the target, and high speed -measurement accuracy. However, when measuring the velocity of a solid surface, an LDV can scale the speed only within a limited range. When the moving surface is beyond the measurable range of the LDV, the intensity of the scattered light decreases, and the quality factor of the Doppler signal reduces. A Doppler signal is validated by the quality factor Q, which directly determines the working distance and measurable range of the LDV. When the quality factor is below the threshold, the carrier velocity cannot be determined from the Doppler signal. To meet the requirements of the measurable range, the quality factor is traditionally enhanced by two lenses with fixed focal length, which change the position of the waist spot of the outgoing Gaussian beam. However, this method increases the distance between the lenses and excessively expands the LDV volume. Meanwhile, the measurement scope remains limited and non-adaptable to actual situations. To change the measurable range of the LDV, one must either change the distance between the lenses or reform the lens combination. Mechanically transforming the lens distance will increase the volume and the system complexity, largely restricting the operating range of the speedometer. In addition, the lens combination cannot be changed at any time in practical engineering applications. No other reasonable method can expand the measuring range. Herein we present a beam transformation system based on a liquid lens. The waist-spot position of the Gaussian beam is controlled by changing the driving current, enhancing the quality factor above the threshold over a considerable range. Our design greatly improves the working distance and measurable range of the LDV. We hope that our basic strategy and findings will benefit the speed measurement and navigation ability of the carrier. s This paper combines a theoretical analysis and simulation with experimental verification. In the theoretical analysis, we first evaluated the feasibility of transforming the LDV's Gaussian beam through a liquid lens. Based on Gaussian optics, the positions and size of the waist spot were simulated under different driving currents of an electrically tunable lens (ETL). We then constructed an LDV with the ETL and changed the position of its waist spot by changing the driving current without increasing the displacement mechanism. Throughout the experiment, we determined the relationship between the quality factor of a single point and the driving current, and the working distance and measuring range of the LDV for different offset lenses. Results and Discussions The presented method improved the working distance and measurable range of the LDV. Owing to the sharp response time of the liquid lens (in order of milliseconds) (Table 1), the driving current can be controlled by a feedback signal, achieving real-time adjustment of the liquid lens ( Fig. 5). In the new LDV structure, the maximum quality factor of a single measuring point reaches 3482, 22. 9 times that of a traditional speedometer (Fig. 9). When the F011 = 25.4 mm offset lens was selected, the working distance of the LDV was changed to the maximum extent, with a measuring range of 0.7-3.3 m. The system volume was reduced at the same time (Fig. 10, Table 2). Conclusions This paper proposes a novel LDV scheme based on a liquid lens. Within this design, the waist spot position of the Gaussian beam can move and the working distance of the LDV can be changed simply by controlling the driving current, without increasing the displacement mechanism. Therefore, the quality factor of the Doppler signal is greatly improved. The quality factor of a single measuring point is maximized at 3482, 22. 9 times that of a traditional speedometer. The new structure improves the measuring range of the LDV to 0.7-3.3 m, 4.3 times that of the traditional structure ( 1. 2-1. 8 m), while reducing the volume of the speed measurement system. These improvements will greatly expand the engineering applications of LDVs.
引用
收藏
页数:9
相关论文
共 9 条
  • [1] Compact optical design solutions using focus tunable lenses
    Blum, M.
    Bueeler, M.
    Graetzel, C.
    Aschwanden, M.
    [J]. OPTICAL DESIGN AND ENGINEERING IV, 2011, 8167
  • [2] [杜振辉 Du Zhenhui], 2003, [光电子·激光, Journal of Optoelectronics·Laser], V14, P977
  • [3] Durst F M, 1976, J APPL MECH, V44, P518
  • [4] Huang Hua, 2010, Journal of Applied Optics, V31, P151
  • [5] Method for Establishing New Integrated Navigation System Based on Two-Dimensional Laser Doppler Velocimeter
    Li Wentao
    Nie Xiaoming
    Zhou Jian
    [J]. CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2020, 47 (03):
  • [6] Detection of Rotational Cylinder Speed Using Doppler Effect of Optical Vortex
    Qiu Song
    Ren Yuan
    Liu Tong
    Wang Chen
    [J]. ACTA OPTICA SINICA, 2020, 40 (20)
  • [7] LOCALIZED FLUID FLOW MEASUREMENTS WITH AN HE-NE LASER SPECTROMETER1 ( E )
    YEH, Y
    CUMMINS, HZ
    [J]. APPLIED PHYSICS LETTERS, 1964, 4 (10) : 176 - &
  • [8] Zhou J, 2011, PRELIMINARY STUDY LA, P104
  • [9] Laser Doppler velocimeter using a single longitudinal mode solid-state laser source
    Zhou, Jian
    Long, Xingwu
    [J]. OPTICS AND LASER TECHNOLOGY, 2010, 42 (07): : 1167 - 1171