Comparison of transmission and transflectance mode FTIR imaging of biological tissue

被引:25
|
作者
Pilling, Michael J. [1 ,2 ]
Bassan, Paul [1 ,2 ,3 ]
Gardner, Peter [1 ,2 ]
机构
[1] Univ Manchester, Manchester Inst Biotechnol, Manchester M1 7DN, Lancs, England
[2] Univ Manchester, Sch Chem Engn & Analyt Sci, Manchester M13 9PL, Lancs, England
[3] London Spect Ltd, London TN13 2UU, England
基金
英国工程与自然科学研究理事会;
关键词
TRANSFORM INFRARED MICROSPECTROSCOPY; PROSTATE-CANCER; MICRO-SPECTROSCOPY; CELLS; HISTOPATHOLOGY; THICKNESS; SECTIONS; SPECTRA; GRADE;
D O I
10.1039/c4an01975j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
FTIR microscopy is a powerful technique which has become popular due to its ability to provide complementary information during histopathological assessment of biomedical tissue samples. Recently however, questions have been raised on the suitability of the transflection mode of operation for clinical diagnosis due to the so called Electric Field Standing Wave (EFSW) effect. In this paper we compare chemical images measured in transmission and transflection from prostate tissue obtained from five different patients, and discuss the variability of the spectra acquired with each sampling modality. We find that spectra obtained in transflection undergo a non-linear distortion, i.e. non-linear variations in absorption band strength across the spectra, and that there are significant differences in spectra measured from the same area of tissue depending on the mode of operation. Principal Component Analysis (PCA) is used to highlight that poorer discrimination between benign and cancerous tissue is obtained in transflection mode. In addition we show that use of second derivatives, while qualitatively improves spectral discrimination, does not completely alleviate the underlying problem.
引用
收藏
页码:2383 / 2392
页数:10
相关论文
共 50 条
  • [1] Comparison of transflection and transmission FTIR imaging measurements performed on differentially fixed tissue sections
    Perez-Guaita, David
    Heraud, Philip
    Marzec, Katarzyna M.
    de la Guardia, Miguel
    Kiupel, Matti
    Wood, Bayden R.
    ANALYST, 2015, 140 (07) : 2376 - 2382
  • [2] A comparison of Raman, FTIR and ATR-FTIR micro spectroscopy for imaging human skin tissue sections
    Ali, S. M.
    Bonnier, F.
    Lambkin, H.
    Flynn, K.
    McDonagh, V.
    Healy, C.
    Lee, T. C.
    Lyng, F. M.
    Byrne, H. J.
    ANALYTICAL METHODS, 2013, 5 (09) : 2281 - 2291
  • [3] Deep reflection-mode photoacoustic imaging of biological tissue
    Song, Kwang Hyun
    Wang, Lihong V.
    JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (06)
  • [4] Nonlinearity parameter B/A of biological tissue ultrasound imaging in echo mode
    Toulemonde, M.
    Varray, F.
    Bernard, A.
    Basset, O.
    Cachard, C.
    RECENT DEVELOPMENTS IN NONLINEAR ACOUSTICS, 2015, 1685
  • [5] Comparison of fluorescence lifetime and multispectral imaging for quantitative multiplexing in biological tissue
    Pal, Rahul
    Kumar, Anand T. N.
    BIOMEDICAL OPTICS EXPRESS, 2022, 13 (07): : 3854 - 3868
  • [6] Macro FTIR imaging in transmission under a controlled environment
    Chan, K. L. A.
    Kazarian, S. G.
    VIBRATIONAL SPECTROSCOPY, 2006, 42 (01) : 130 - 134
  • [7] Assessment of paraffin removal from prostate FFPE sections using transmission mode FTIR-FPA imaging
    Hughes, Caryn
    Gaunt, Lydia
    Brown, Michael
    Clarke, Noel W.
    Gardner, Peter
    ANALYTICAL METHODS, 2014, 6 (04) : 1028 - 1035
  • [8] Transcranial sonography of the brain parenchyma:: Comparison of B-mode imaging and tissue harmonic imaging
    Puls, I
    Berg, D
    Mäurer, M
    Schliesser, M
    Hetzel, G
    Becker, G
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (02): : 189 - 194
  • [9] ACOUSTICAL IMAGING OF BIOLOGICAL TISSUE
    THURSTONE, FL
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1970, SU17 (03): : 154 - +
  • [10] Raman and FTIR imaging of lung tissue: bronchopulmonary sequestration
    Krafft, Christoph
    Codrich, Daniela
    Pelizzo, Gloria
    Sergo, Valter
    JOURNAL OF RAMAN SPECTROSCOPY, 2009, 40 (06) : 595 - 603