Continuous flow-through solid phase spectrophotometric determination of trace amounts of zinc

被引:29
|
作者
Ayora-Cañada, MJ [1 ]
Pascual-Reguera, MI [1 ]
Molina-Díaz, A [1 ]
机构
[1] Univ Jaen, Fac Expt Sci, Dept Phys & Analyt Chem, E-23071 Jaen, Spain
关键词
flow injection analysis; solid phase spectroscopy; flow-through sensor; zinc;
D O I
10.1016/S0003-2670(98)00506-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-through solid phase spectrophotometric sensing device for the determination of Zn(II) was developed based on the reaction of this ion with 1-(2-pyridylazo)-2-naphthol (PAN) immobilized on a Dowex cation exchanger placed in a flow-through cell. The reaction of Zn(II) with immobilized PAN and its retention on the resin developed the analytical signal. Adequate dissociation of the Zn-PAN complex left the unaltered reagent fixed on the solid support, enabling the regeneration of the sensor. The sensor allows working with several calibration Lines simply by varying the sample volume injected for the determination. As an example, linear dynamic ranges from 0.2 to 4.0 mu g ml(-1) and from 20 to 500 mu g l(-1) can be obtained by using 100 and 2000 mu l, respectively, with detection limits being 0.05 mu g ml(-1) and 5 mu g l(-1), respectively. The RSD (%) being 2.1 (100 mu l) and 2.3 (2000 mu l) and the sampling frequency 38 and 15 samples per hour, respectively. The sensor was applied to the determination of Zn(II) in real samples, namely, human hair, pharmaceutical and cosmetic preparations and water samples. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:71 / 80
页数:10
相关论文
共 50 条
  • [1] Determination of trace amounts of copper using a flow-through spectrophotometric sensor
    Herrera, JMC
    Rojas, FS
    Ojeda, CB
    de Torres, AG
    Pavón, JMC
    LABORATORY ROBOTICS AND AUTOMATION, 2000, 12 (05) : 241 - 245
  • [2] Flow-through solid phase UV spectrophotometric determination of amoxycillin
    Medina, AR
    de Córdova, MLF
    Díaz, AM
    ANALYTICAL LETTERS, 1999, 32 (04) : 729 - 742
  • [3] Determination of ascorbic acid by use of a flow-through solid phase UV spectrophotometric system
    A. Molina-Díaz
    A. Ruiz-Medina
    M. L. Fernández-de Córdova
    Fresenius' Journal of Analytical Chemistry, 1999, 363 : 92 - 97
  • [4] Determination of ascorbic acid by use of a flow-through solid phase UV spectrophotometric system
    Molina-Díaz, A
    Ruiz-Medina, A
    Fernández-de Córdova, ML
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 363 (01): : 92 - 97
  • [5] Palladium determination using flow-through spectrophotometric sensing phase
    Arndt, M
    Zadrozna, I
    Dybko, A
    Wróblewski, W
    Kasiura, K
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 90 (1-3): : 332 - 336
  • [6] Solid phase extraction and spectrophotometric determination of trace amounts of thiocyanate in real samples
    Ghaedi, Mehrorang
    Parham, Hooshang
    Moghadam, Majid
    Mortazavi, Kianosh
    Soylak, Mustafa
    ANNALI DI CHIMICA, 2006, 96 (11-12) : 689 - 696
  • [7] Sensitive determination of adrenaline by means of a flow-through solid phase UV spectrophotometric sensing device
    Medina A.R.
    De Córdova M.L.F.
    Díaz A.M.
    Mikrochimica Acta, 2000, 134 (1-2) : 101 - 105
  • [8] Flow injection spectrophotometric determination of trace amounts of selenium
    Mousavi, MF
    Ghiasvand, AR
    Jahanshahi, AR
    TALANTA, 1998, 46 (05) : 1011 - 1017
  • [9] Solid-phase extraction and spectrophotometric determination of trace amounts of mercury in natural samples
    Kara, D
    Tekin, N
    MICROCHIMICA ACTA, 2005, 149 (3-4) : 193 - 198
  • [10] Solid-phase extraction and spectrophotometric determination of trace amounts of copper in water samples
    Yamini, Y
    Tamaddon, A
    TALANTA, 1999, 49 (01) : 119 - 124