A High Performance Neutron Powder Diffractometer at 3MW Triga Mark-II Research Reactor in Bangladesh

被引:2
|
作者
Kamal, I. [1 ]
Yunus, S. M. [1 ]
Datta, T. K. [1 ]
Zakaria, A. K. M. [1 ]
Das, A. K. [1 ]
Aktar, S. [1 ]
Hossain, S. [1 ]
Berliner, R. [2 ]
Yelon, W. B. [3 ]
机构
[1] Atom Energy Res Estab, Inst Nucl Sci & Technol, Dhaka, Bangladesh
[2] Instrumentat Associates, Durham, NC USA
[3] Oak Ridge Natl Lab, Oak Ridge, TN USA
关键词
DIFFRACTION; REFINEMENT;
D O I
10.1063/1.4958454
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A high performance neutron diffractometer called Savar Neutron Diffractometer (SAND) was built and installed at radial beam port-2 of TRIGA Mark II research reactor at AERE, Savar, Dhaka, Bangladesh. Structural studies of materials are being done by this technique to characterize materials crystallograpohically and magnetically. The micro-structural information obtainable by neutron scattering method is very essential for determining its technological applications. This technique is unique for understanding the magnetic behavior in magnetic materials. Ceramic, steel, electronic and electric industries can be benefited from this facility for improving their products and fabrication process. This instrument consists of a Popovicimonochromator with a large linear position sensitive detector array. The monochromator consists of nine blades of perfect single crystal of silicon with 6mm thickness each. The monochromator design was optimized to provide maximum flux on 3mm diameter cylindrical sample with a relatively flat angular dependence of resolution. Five different wave lengths can be selected by orienting the crystal at various angles. A sapphire filter was used before the primary collimator to minimize the first neutron. The detector assembly is composed of 15 linear position sensitive proportional counters placed at either 1.1 m or 1.6 m from the sample position and enclosed in a air pad supported high density polythene shield. Position sensing is obtained by charge division using 1-wide NIM position encoding modules (PEM). The PEMs communicate with the host computer via USB. The detector when placed at 1.1 m, subtends 30 degrees (2) at each step and covers 120 degrees in 4 steps. When the detector is placed at 1.6 m it subtends 20 degrees at each step and covers 120 degrees in 6 steps. The instrument supports both low and high temperature sample environment. The instrument supports both low and high temperature sample environment. The diffractometer is a state-of-the art technology for diffraction study in our country.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Experience with the operation, maintenance and utilisation of the 3 MW TRIGA Mark-II research reactor of Bangladesh
    Zulquarnain, M.A.
    Haque, M.M.
    Salam, M.A.
    Islam, M.S.
    Saha, P.K.
    Sarder, M.A.
    Haque, A.
    Soner, M.A.M.
    Uddin, M.M.
    Rahman, M.M.
    Kamal, I.
    Islam, M.N.
    Hossain, S.M.
    International Journal of Nuclear Energy Science and Technology, 2009, 4 (04) : 299 - 312
  • [2] Measurement of neutronic safety parameters of the 3 MW TRIGA Mark-II research reactor
    Salam, M. A.
    Soner, M. A. M.
    Sarder, M. A.
    Hague, A.
    Uddin, M. M.
    Rahman, A.
    Rahman, M. M.
    Sarkar, M. M.
    Islam, S. M. A.
    PROGRESS IN NUCLEAR ENERGY, 2014, 74 : 160 - 165
  • [3] Assessment of radiological consequences to a hypothetical accident of the 3-MW TRIGA Mark-II nuclear research reactor of Bangladesh
    Mawla, Md Rosaidul
    Rahman, Anisur
    Mollah, Abdus Sattar
    Ryean, Radmim
    Islam, Md. Shafiqul
    NUCLEAR ENGINEERING AND DESIGN, 2024, 424
  • [4] Neutronics analysis of the 3 MW TRIGA Mark-II research reactor by using SRAC code system
    Sarker, M. M.
    Bhuiyan, S. I.
    Akramuzzaman, M. M.
    ANNALS OF NUCLEAR ENERGY, 2008, 35 (06) : 1140 - 1146
  • [5] NEUTRON DOSIMETRY AND DAMAGE CALCULATIONS FOR THE TRIGA MARK-II REACTOR IN VIENNA
    WEBER, HW
    BOCK, H
    UNFRIED, E
    GREENWOOD, LR
    JOURNAL OF NUCLEAR MATERIALS, 1986, 137 (03) : 236 - 240
  • [6] Thermal hydraulic transient study of 3 MW TRIGA Mark-II research reactor of Bangladesh using the EUREKA-2/RR code
    Badrun, N. H.
    Altaf, M. H.
    Khan, M. J. H.
    Mahmood, M. S.
    Motalab, M. A.
    Lyric, Z. I.
    ANNALS OF NUCLEAR ENERGY, 2012, 41 : 40 - 47
  • [7] Using TRIGA Mark-II Research Reactor for Irradiation with Thermal Neutrons
    Kolsek, Aljaz
    Radulovic, Vladimir
    Snoj, Luka
    22ND INTERNATIONAL CONFERENCE NUCLEAR ENERGY FOR NEW EUROPE, (NENE 2013), 2013,
  • [8] Analysis of kinetic parameters of 3 MW TRIGA Mark-II research reactor using the SRAC2006 code system
    Khan, M. J. H.
    Sarker, M. M.
    Islam, S. M. A.
    ANNALS OF NUCLEAR ENERGY, 2013, 60 : 181 - 186
  • [9] GENERATION OF A LIBRARY FOR REACTOR CALCULATIONS AND SOME APPLICATIONS IN CORE AND SAFETY PARAMETER STUDIES OF THE 3-MW TRIGA MARK-II RESEARCH REACTOR
    BHUIYAN, SI
    KHAN, AR
    SARKER, MM
    RAHMAN, M
    ARA, ZG
    MUSA, M
    MANNAN, MA
    MELE, I
    NUCLEAR TECHNOLOGY, 1992, 97 (03) : 253 - 263
  • [10] A Trajectory Tracking FLC Tuned with PSO for Triga Mark-II Nuclear Research Reactor
    Lokman, Gurcan
    Baba, A. Fevzi
    Topuz, Vedat
    KNOWLEDGE-BASED AND INTELLIGENT INFORMATION AND ENGINEERING SYSTEMS, PT I: 15TH INTERNATIONAL CONFERENCE, KES 2011, 2011, 6881 : 90 - 99