Suction cup on a piston-based chest compression device improves coronary perfusion pressure and cerebral oxygenation during experimental cardiopulmonary resuscitation

被引:4
|
作者
Malberg, Johan [1 ,2 ]
Smekal, David [1 ,2 ]
Marchesi, Silvia [3 ]
Lipcsey, Miklos [2 ,4 ]
Rubertsson, Sten [2 ]
机构
[1] Uppsala Univ Hosp, Emergency Med Serv EMS, Sjukhusvagen, S-75185 Uppsala, Sweden
[2] Uppsala Univ, Surg Sci Dept Sjukhusvagen, Anesthesia & Intens Care Serv, Sjukhusvagen, S-75185 Uppsala, Sweden
[3] Jolife Stryker AB, S-23633 Scheelevagen, Sweden
[4] Uppsala Univ Hosp, Hedenstierna Lab, Sjukhusvagen, S-75185 Uppsala, Sweden
来源
RESUSCITATION PLUS | 2022年 / 12卷
关键词
Mechanical chest compression; Coronary perfusion pressure; Cerebral oxygenation; suction cup; Piston-based device; CARDIAC-ARREST; CPR; LUCAS; DECOMPRESSION; INJURIES; STANDARD;
D O I
10.1016/j.resplu.2022.100311
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The presented study aimed to investigate whether a mechanical chest compression piston device with a suction cup assisting chest recoil could impact the hemodynamic status when compared to a bare piston during cardiopulmonary resuscitation. Methods: 16 piglets were anesthetized and randomized into 2 groups. After 3 minutes of induced ventricular fibrillation, a LUCAS 3 device was used to perform chest compressions, in one group a suction cup was mounted on the device's piston, while in the other group, compressions were per -formed by the bare piston. The device was used in 30:2 mode and the animals were manually ventilated. Endpoints of the study were: end tidal carbon dioxide, coronary and cerebral perfusion pressures, and brain oxygenation (measured using near infrared spectroscopy). At the end of the protocol, the animals that got a return to spontaneous circulation were observed for 60 minutes, then euthanized.Results: No difference was found in end tidal carbon dioxide or tidal volumes. Coronary perfusion pressure and cerebral oxygenation were higher in the Suction cup group over the entire experiment time, while cerebral perfusion pressure was higher only in the last 5 minutes of CPR. A passive tidal volume (air going in and out the airways during compressions) was detected and found correlated to end tidal carbon dioxide.Conclusions: The use of a suction cup on a piston-based chest compression device did not increase end tidal carbon dioxide, but it was associated to a higher coronary perfusion pressure.
引用
收藏
页数:8
相关论文
共 28 条
  • [1] Does chest compression during cardiopulmonary resuscitation provide sufficient cerebral oxygenation?
    Yazar, Mehmet Akif
    Acikgoz, Mehmet Baris
    Bayram, Adnan
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2019, 49 (01) : 311 - 317
  • [2] CORONARY PERFUSION-PRESSURE DURING EXPERIMENTAL CARDIOPULMONARY RESUSCITATION
    NIEMANN, JT
    ROSBOROUGH, JP
    UNG, S
    CRILEY, JM
    ANNALS OF EMERGENCY MEDICINE, 1982, 11 (03) : 127 - 131
  • [3] Chest compression synchronized ventilation during prolonged experimental cardiopulmonary resuscitation improves oxygenation but may cause pneumothoraces
    Kopra, Jukka
    Mehtonen, Lassi
    Laitinen, Merja
    Litonius, Erik
    Arvola, Oiva
    Ostman, Robert
    Heinonen, Juho A.
    Skrifvars, Markus B.
    Pekkarinen, Pirkka T.
    RESUSCITATION PLUS, 2025, 22
  • [4] EFFECT OF COMPRESSION RATE ON CORONARY PERFUSION-PRESSURE DURING CARDIOPULMONARY RESUSCITATION
    SANDERS, AB
    EWY, GA
    TAFT, TV
    CLINICAL RESEARCH, 1984, 32 (01): : A12 - A12
  • [5] Miniaturized Chest Compressor Improves Cerebral Perfusion Without Increases in Intracranial Pressure During Cardiopulmonary Resuscitation in a Porcine Model
    Xu, Jiefeng
    Hu, Xianwen
    Wu, Xiaobo
    Sun, Shijie
    Tang, Wanchun
    CIRCULATION, 2013, 128 (22)
  • [6] Intraosseous vasopressin improves coronary perfusion pressure rapidly during cardiopulmonary resuscitation in pigs
    Wenzel, V
    Lindner, KH
    Augenstein, S
    Voelckel, W
    Strohmenger, HU
    Prengel, AW
    Steinbach, G
    CIRCULATION, 1998, 98 (17) : 477 - 477
  • [7] Intraosseous vasopressin improves coronary perfusion pressure rapidly during cardiopulmonary resuscitation in pigs
    Wenzel, V
    Lindner, KH
    Augenstein, S
    Voelckel, W
    Strohmenger, HU
    Prengel, AW
    Steinbach, G
    CRITICAL CARE MEDICINE, 1999, 27 (08) : 1565 - 1569
  • [8] SELECTIVE AORTIC PERFUSION AND OXYGENATION - AN EFFECTIVE ADJUNCT TO EXTERNAL CHEST COMPRESSION-BASED CARDIOPULMONARY-RESUSCITATION
    PARADIS, NA
    ROSE, MI
    GAWRYL, MS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (02) : 497 - 504
  • [9] Cardiopulmonary Resuscitation With Mechanical Chest Compression Device During Percutaneous Coronary Intervention. A Case Report
    Ujvarosy, Dora
    Sebestyen, Veronika
    otvos, Tamas
    Ratku, Balazs
    Lorincz, Istvan
    Szuk, Tibor
    Csanadi, Zoltan
    Berenyi, Ervin
    Szabo, Zoltan
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [10] Effect of an automated ventilator and the impedance threshold device on coronary perfusion pressure and cerebral blood flow during cardiopulmonary resuscitation in pigs
    Zhong, Jing-Quan
    Hu, Xudong
    Hare, Gregory M.
    Mazer, C. D.
    So, Petsy P.
    Debicki, Donna
    Dorian, Paul
    CIRCULATION, 2006, 114 (18) : 553 - 553