Measurement of electrostatic tip-sample interactions by time-domain Kelvin probe force microscopy

被引:3
|
作者
Ritz, Christian [1 ]
Wagner, Tino [1 ,2 ]
Stemmer, Andreas [1 ]
机构
[1] Swiss Fed Inst Technol, Nanotechnol Grp, Saumerstr 4, CH-8803 Ruschlikon, Switzerland
[2] Zurich Instruments AG, Technoparkstr 1, CH-8005 Zurich, Switzerland
来源
关键词
atomic force microscopy (AFM); electrostatic height error; extended Kalman filter; Kelvin probe force microscopy (KFM); time domain; CHARGE; SURFACES; GRAPHENE; STATE;
D O I
10.3762/bjnano.11.76
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Kelvin probe force microscopy is a scanning probe technique used to quantify the local electrostatic potential of a surface. In common implementations, the bias voltage between the tip and the sample is modulated. The resulting electrostatic force or force gradient is detected via lock-in techniques and canceled by adjusting the dc component of the tip-sample bias. This allows for an electrostatic characterization and simultaneously minimizes the electrostatic influence onto the topography measurement. However, a static contribution due to the bias modulation itself remains uncompensated, which can induce topographic height errors. Here, we demonstrate an alternative approach to find the surface potential without lock-in detection. Our method operates directly on the frequency-shift signal measured in frequency-modulated atomic force microscopy and continuously estimates the electrostatic influence due to the applied voltage modulation. This results in a continuous measurement of the local surface potential, the capacitance gradient, and the frequency shift induced by surface topography. In contrast to conventional techniques, the detection of the topography-induced frequency shift enables the compensation of all electrostatic influences, including the component arising from the bias modulation. This constitutes an important improvement over conventional techniques and paves the way for more reliable and accurate measurements of electrostatics and topography.
引用
收藏
页码:911 / 921
页数:11
相关论文
共 50 条
  • [1] Measurement of electrostatic tip-sample interactions by time-domain Kelvin probe force microscopy
    Ritz C.
    Wagner T.
    Stemmer A.
    Ritz, Christian (critz@ethz.ch), 1600, Beilstein-Institut Zur Forderung der Chemischen Wissenschaften (11): : 911 - 921
  • [2] Tip-Sample Interactions in Kelvin Probe Force Microscopy: Quantitative Measurement of the Local Surface Potential
    Liscio, Andrea
    Palermo, Vincenzo
    Muellen, Klaus
    Samori, Paolo
    JOURNAL OF PHYSICAL CHEMISTRY C, 2008, 112 (44): : 17368 - 17377
  • [3] Electrostatic tip-sample interaction in immersion force microscopy of semiconductors
    Donolato, C
    PHYSICAL REVIEW B, 1996, 54 (03): : 1478 - 1481
  • [5] Quantitative measurement of tip-sample interactions in amplitude modulation atomic force microscopy
    Hoelscher, H.
    APPLIED PHYSICS LETTERS, 2006, 89 (12)
  • [6] Tip geometry and tip-sample interactions in scanning probe microscopy (SPM)
    Koenders, L
    Yacoot, A
    FRINGE 2005, 2006, : 456 - +
  • [7] Stochastic simulation of tip-sample interactions in atomic force microscopy
    Labuda, Aleksander
    Lysy, Martin
    Gruetter, Peter
    APPLIED PHYSICS LETTERS, 2012, 101 (11)
  • [8] Tip-sample interactions in dynamic force microscopy of polyvinyl alcohol films
    Haugstad, G
    Gladfelter, WL
    Jones, RR
    POLYMER INTERNATIONAL, 2000, 49 (05) : 427 - 431
  • [9] Reduction of tip-sample contact using dielectrophoretic force scanning probe microscopy
    Hilton, AM
    Lynch, BP
    Simpson, GJ
    ANALYTICAL CHEMISTRY, 2005, 77 (24) : 8008 - 8012
  • [10] Study of tip-sample interaction in scanning force microscopy
    Luna, M
    Colchero, J
    Gómez-Herrero, J
    Baró, AM
    APPLIED SURFACE SCIENCE, 2000, 157 (04) : 285 - 289