In vivo comparison of tantalum, tungsten, and bismuth enteric contrast agents to complement intravenous iodine for double-contrast dual-energy CT of the bowel

被引:38
|
作者
Rathnayake, Samira [1 ]
Mongan, John [1 ]
Torres, Andrew S. [2 ]
Colborn, Robert [2 ]
Gao, Dong-Wei [1 ]
Yeh, Benjamin M. [1 ]
Fu, Yanjun [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] GE Global Res, 1 Res Circle, Niskayuna, NY USA
基金
美国国家卫生研究院;
关键词
dual-energy CT; CT enterography; contrast agent; tungsten; bismuth; tantalum; small bowel; COMPUTED-TOMOGRAPHY; CROHNS-DISEASE; CAPSULE ENDOSCOPY; IMAGING AGENT; MEDIA; METAL; NANOPARTICLES; ENTEROGRAPHY; POWDER;
D O I
10.1002/cmmi.1687
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the ability of dual-energy CT (DECT) to separate intravenous contrast of bowel wall from intraluminal contrast, we scanned 16 rabbits on a clinical DECT scanner: n = 3 using only iodinated intravenous contrast, and n = 13 double-contrast enhanced scans using iodinated intravenous contrast and experimental enteric non-iodinated contrast agents in the bowel lumen (five bismuth, four tungsten, and four tantalum based). Representative image pairs from conventional CT images and DECT iodine density maps of small bowel (116 pairs from 232 images) were viewed by four abdominal imaging attending radiologists to independently score each comparison pair on a visual analog scale (-100 to +100%) for (1) preference in small bowel wall visualization and (2) preference in completeness of intraluminal enteric contrast subtraction. Median small bowel wall visualization was scored 39 and 42 percentage points (95% CI 30-44% and 36-45%, both p < 0.001) higher for double-contrast DECT than for conventional CT with enteric tungsten and tantalum contrast, respectively. Median small bowel wall visualization for double-contrast DECT was scored 29 and 35 percentage points (95% CI 20-35% and 33-39%, both p < 0.001) higher with enteric tungsten and tantalum, respectively, than with bismuth contrast. Median completeness of intraluminal enteric contrast subtraction in double-contrast DECT iodine density maps was scored 28 and 29 percentage points (95% CI 15-31% and 28-33%, both p < 0.001) higher with enteric tungsten and tantalum, respectively, than with bismuth contrast. Results suggest that in vivo double-contrast DECT with iodinated intravenous and either tantalum-or tungsten-based enteric contrast provides better visualization of small bowel than conventional CT. Copyright (C) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:254 / 261
页数:8
相关论文
共 50 条
  • [1] Bowel Peristalsis Artifact on Dual-Energy CT: In Vitro Study on the Influence of Different Dual-Energy CT Platforms and Enteric Contrast Agents
    Obmann, Markus M.
    Sun, Yuxin
    An, Chansik
    Ohliger, Michael A.
    Wang, Zhen J.
    Yeh, Benjamin M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (02) : 290 - 299
  • [2] Arterial Double-Contrast Dual-Energy MDCT: In-Vivo Rabbit Atherosclerosis with Iodinated Nanoparticles and Gadolinium Agents
    Carmi, Raz
    Kafri, Galit
    Altman, Ami
    Goshen, Liran
    Planer, David
    Sosna, Jacob
    MEDICAL IMAGING 2010: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2010, 7626
  • [3] Toward Biphasic Computed Tomography (CT) Enteric Contrast: Material Classification of Luminal Bismuth and Mural Iodine in a Small-Bowel Phantom Using Dual-Energy CT
    Qu, Mingliang
    Ehman, Eric
    Fletcher, Joel G.
    Huprich, James E.
    Hara, Amy K.
    Silva, Alvin C.
    Farrugia, Gianrico
    Limburg, Paul
    McCollough, Cynthia H.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (05) : 554 - 559
  • [4] In Vivo Differentiation of Complementary Contrast Media at Dual-Energy CT
    Mongan, John
    Rathnayake, Samira
    Fu, Yanjun
    Wang, Runtang
    Jones, Ella F.
    Gao, Dong-Wei
    Yeh, Benjamin M.
    RADIOLOGY, 2012, 265 (01) : 267 - 272
  • [5] Quantifying iodine concentration in the normal bowel wall using dual-energy CT: influence of patient and contrast characteristics
    Majida Nehnahi
    Gabriel Simon
    Romain Moinet
    Gael Piton
    Camille Camelin
    Maxime Ronot
    Éric Delabrousse
    Paul Calame
    Scientific Reports, 13
  • [6] Quantifying iodine concentration in the normal bowel wall using dual-energy CT: influence of patient and contrast characteristics
    Nehnahi, Majida
    Simon, Gabriel
    Moinet, Romain
    Piton, Gael
    Camelin, Camille
    Ronot, Maxime
    Delabrousse, Eric
    Calame, Paul
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [7] Contrast thresholds for detection of various iodine concentrations in subtraction CT and dual-energy CT systems
    Heshmat, Anahita
    Barreto, Izabella
    Rill, Lynn
    Liu, Sitong
    Patel, Romin
    Arreola, Manuel
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (01):
  • [8] Dual-energy CT iodine overlay improves efficiency of oral contrast leak assessment
    Hinen, Shaun P.
    Griffith III, Joseph P.
    Chamberlin, Jordan
    Waltz, Jeffrey
    Kocher, Madison
    Krull, Veronica
    Young, Tristan
    Litvin, Cara B.
    Varga-Szemes, Akos
    Hardie, Andrew D.
    ACTA RADIOLOGICA, 2023, 64 (08) : 2357 - 2362
  • [9] Quantitative comparison of dual-energy CT and differential phase contrast CT imaging methods
    Zhang, Xin
    Su, Ting
    Xia, Dongmei
    Liang, Dong
    Ge, Yongshuai
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [10] Iodine material density images in dual-energy CT: quantification of contrast uptake and washout in HCC
    Pfeiffer, Daniela
    Parakh, Anushri
    Patino, Manuel
    Kambadakone, Avinash
    Rummeny, Ernst J.
    Sahani, Dushyant V.
    ABDOMINAL RADIOLOGY, 2018, 43 (12) : 3317 - 3323