Laparoscopic colon surgery:: unreliability of end-tidal CO2 monitoring

被引:18
|
作者
Klopfenstein, C. E. [1 ]
Schiffer, E. [1 ]
Pastor, C. M. [1 ,2 ]
Beaussier, M. [3 ]
Francis, K. [2 ]
Soravia, C. [2 ]
Herrmann, F. R. [4 ]
机构
[1] Univ Hosp, Serv Anaesthesiol, CH-1211 Geneva, Switzerland
[2] Univ Hosp, Clin Visceral Surg, CH-1211 Geneva, Switzerland
[3] Hosp St Antoine, Dept Anaesthesiol, Paris, France
[4] Univ Hosp, Dept Rehabil & Geriat, CH-1211 Geneva, Switzerland
关键词
carbon dioxide; measurement; patient position; colon surgery; laparoscopy;
D O I
10.1111/j.1399-6576.2007.01568.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The relatively good haemodynamic and respiratory tolerance to abdominal CO2 insufflation has mostly been observed in healthy patients during short-lasting laparoscopic procedures. End-tidal CO2 pressure (PetCO(2)) has been shown to be a reliable method to assess arterial CO2 (PaCO2) in the absence of cardio-respiratory disease in this setting. However, no study has investigated whether PetCO(2) is accurately related to PaCO2 during laparoscopic colon surgery. Indeed, these procedures last longer, prolonging the pneumoperitoneum and requiring a Trendelenburg position. The aim of the present study was to measure the PaCO2-PetCO(2) difference over time in patients undergoing laparoscopic colon surgery and to determine whether PaCO2 is reliably assessed by PetCO(2). Methods: Forty consecutive patients (ASA I and II) scheduled for laparoscopic colon surgery were anaesthetized and ventilated to obtain a PetCO(2) between 4.0 and 5.5 kPa. After initiation of CO2 insufflation, PaCO2 and PetCO(2) were recorded every 30 min during surgery. Results: No complication was observed during anaesthesia. The mean arterial pressure increased significantly after CO2 insufflation and remained steady up to the end of pneumoperitoneum. The heart rate remained stable over time. The relation between PaCO2 and PetCO(2) was not constant among patients and increased over time within the same patients. The R-2 values fluctuated and did not show a constant correlation between PaCO2 and PetCO(2). Conclusion: The correlation between PaCO2 and PetCO(2) during laparoscopic colon surgery is inconsistent mainly due to inter- and intra-individual variability.
引用
收藏
页码:700 / 707
页数:8
相关论文
共 50 条
  • [1] Nasal end-tidal CO2 monitoring
    Weeks, DB
    ANESTHESIOLOGY, 1998, 88 (02) : 547 - 547
  • [2] An Update on End-Tidal CO2 Monitoring
    Selby, Samuel T.
    Abramo, Thomas
    Hobart-Porter, Nicholas
    PEDIATRIC EMERGENCY CARE, 2018, 34 (12) : 888 - 892
  • [3] Use of Maximum End-Tidal CO2 Values to Improve End-Tidal CO2 Monitoring Accuracy
    Galia, Fabrice
    Brimioulle, Serge
    Bonnier, Frederic
    Vandenbergen, Nicolas
    Dojat, Michel
    Vincent, Jean-Louis
    Brochard, Laurent J.
    RESPIRATORY CARE, 2011, 56 (03) : 278 - 283
  • [4] End-tidal CO2 monitoring in emergency medicine
    Brambrink, AM
    ANAESTHESIST, 1997, 46 (07): : 604 - 612
  • [5] Not the end of end-tidal CO2
    Shah, Kaushal
    INTERNAL AND EMERGENCY MEDICINE, 2009, 4 (01) : 39 - 40
  • [6] Not the end of end-tidal CO2
    Kaushal Shah
    Internal and Emergency Medicine, 2009, 4 : 39 - 40
  • [7] BLIND NASAL INTUBATION BY MONITORING END-TIDAL CO2
    KING, HK
    WOOTEN, DJ
    ANESTHESIA AND ANALGESIA, 1989, 69 (03): : 412 - 413
  • [8] Application of End-Tidal CO2 Monitoring to ICU Management
    Owens, Bradley
    Hall, Chris
    CRITICAL CARE NURSING QUARTERLY, 2024, 47 (02) : 157 - 162
  • [9] End-tidal CO2 and prognosis
    Herschman, Z
    Lorbert, J
    Rahal, W
    CRITICAL CARE MEDICINE, 1996, 24 (06) : 1093 - 1093
  • [10] END-TIDAL CO2 DETECTION
    HELLER, MB
    YEALY, DM
    SEABERG, DC
    MACLEOD, BA
    GERARD, J
    ANNALS OF EMERGENCY MEDICINE, 1989, 18 (12) : 1375 - 1375