Capabilities and limitations of high-resolution - Inductively coupled plasma - Mass spectrometry (ICP-MS)

被引:0
|
作者
Moor, C [1 ]
Devos, W [1 ]
Bissig, C [1 ]
机构
[1] EMPA, CH-8600 Dubendorf, Switzerland
关键词
inductively coupled plasma; mass spectrometry; sector field mass spectrometry;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Coupling inductively coupled plasmas with sector field mass spectrometers has led to a remarkable improvement of the analytical capabilites in the field of trace element determinations during the last decade. Looking at the analysis of pure water, the limiting factors for determining metal concentrations in the ng/l range are shown. The sensitivity of modern instruments is high enough for most practical purposes, and in our case, the detection limits of all measured elements were limited by blank values. A key factor for the analysis of soil and sediment samples is the content of total dissolved solids. The spectral resolution has to match the requirements given by the spectroscopic interferences. Therefore, a pre-analysis is necessary for diagnostic purposes if the matrix is not sufficiently known to predict the relevant interferences.
引用
收藏
页码:26 / 29
页数:4
相关论文
共 50 条
  • [1] MULTIELEMENT TRACE ANALYSIS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY (ICP-MS) - CAPABILITIES AND LIMITATIONS
    GRAY, AL
    CHEMIA ANALITYCZNA, 1990, 35 (1-3): : 59 - 70
  • [2] Neptunium determination by inductively coupled plasma mass spectrometry (ICP-MS)
    D. E. Vance
    V. F. Belt
    T. J. Oatts
    D. K. Mann
    Journal of Radioanalytical and Nuclear Chemistry, 1998, 234 : 143 - 147
  • [3] INDUCTIVELY-COUPLED PLASMA MASS-SPECTROMETRY (ICP-MS)
    DOUGLAS, DJ
    HOUK, RS
    PROGRESS IN ANALYTICAL ATOMIC SPECTROSCOPY, 1985, 8 (01): : 1 - 18
  • [4] Determination of plutonium by inductively coupled plasma mass spectrometry (ICP-MS)
    S. Tonouchi
    H. Habuki
    K. Katoh
    K. Yamazaki
    T. Hashimoto
    Journal of Radioanalytical and Nuclear Chemistry, 2002, 252 : 367 - 371
  • [5] Determination of plutonium by inductively coupled plasma mass spectrometry (ICP-MS)
    Tonouchi, S
    Habuki, H
    Katoh, K
    Yamazaki, K
    Hashimoto, T
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 252 (02) : 367 - 371
  • [6] Neptunium determination by inductively coupled plasma mass spectrometry (ICP-MS)
    Vance, DE
    Belt, VF
    Oatts, TJ
    Mann, DK
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 234 (1-2) : 143 - 146
  • [7] AN IMPROVED INTERFACE FOR INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS)
    DOUGLAS, DJ
    FRENCH, JB
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (03) : 197 - 204
  • [8] Overview of biomedical applications of inductively coupled plasma mass spectrometry (ICP-MS)
    Bakowska, E
    TRACE ELEMENTS IN MAN AND ANIMALS 10, 2000, : 1121 - 1121
  • [9] Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Applications in Quantitative Proteomics
    Chahrour, Osama
    Malone, John
    PROTEIN AND PEPTIDE LETTERS, 2017, 24 (03): : 253 - 266
  • [10] Determination of Iron in Biological Materials by inductively coupled plasma mass spectrometry (ICP-MS)
    Kana, Antonin
    Mestek, Oto