Evaluation of a commercial diode array (Tomodose) for tomotherapy beam profile measurements

被引:0
|
作者
Wagner, T
Langen, K
Poole, D
Meeks, S
Willoughby, T
Ruchala, K
Olivera, G
机构
[1] MD Anderson Canc Ctr, Orlando, FL USA
[2] TomoTherapy Inc, Madison, WI USA
关键词
D O I
10.1118/1.1997922
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: TomoDose, a commercial diode array (Sun Nuclear Corporation, Melbourne, FL) is used to measure the radiation field in a TomoTherapy Hi* Art linear accelerator. The performance of TomoDose is evaluated by comparing the diode measurements with (i) ion chamber based water tank measurements and (ii) data from an on‐board ion chamber array mounted opposite the linac. Method and Materials: TomoDose has an active area that is rectangular (530 mm by 96 mm) to cover to the maximum field size (50 mm by 400 mm) of the tomotherapy beam. A total of 223 diodes allow a measure of the lateral and longitudinal beam profiles on the central axis and longitudinal profiles 50, 100, and 150 mm off‐axis. Both central axis profiles were compared with ion chamber data obtained in a water tank during an annual quality assurance test. Over a period of about seven weeks, the central axis lateral profile was monitored and compared with profile measurements obtained using the treatment machine's on‐board detector system. Results: TomoDose measurements agreed well with the ion chamber data. A repeated measurement of the lateral profile revealed subtle changes in this profile. Identical trends in profile change were independently measured using an on‐board detector array system. These changes were used for diagnosis of the system's components and can be used to provide early signs of component wear and tear. Conclusion: TomoDose is accurate and can be used for regular, e.g. monthly, monitoring of the beam profiles. It is sensitive to subtle changes in the profile that may be used to provide early warning signs of developing problems. Conflict of Interest: Two of the co‐authors are employees of TomoTherapy, Inc. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1994 / 1994
页数:1
相关论文
共 50 条
  • [1] Evaluation of a diode array for QA measurements on a helical tomotherapy unit
    Langen, KM
    Meeks, SL
    Poole, DO
    Wagner, TH
    Willoughby, TR
    Zeidan, OA
    Kupelian, PA
    Ruchala, KJ
    Olivera, GH
    MEDICAL PHYSICS, 2005, 32 (11) : 3424 - 3430
  • [2] EVALUATION OF A 3D DIODE ARRAY DOSIMETER FOR HELICAL TOMOTHERAPY DELIVERY QA
    Feygelman, Vladimir
    Opp, D.
    Javedan, K.
    Saini, A. J.
    Zhang, G.
    MEDICAL DOSIMETRY, 2010, 35 (04) : 324 - 329
  • [3] On-line exit dose profile measurements by a diode linear array
    Fiorino, C
    Uleri, C
    Cattaneo, GM
    Calandrino, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (08): : 1291 - 1304
  • [4] Evaluation of a New Diode Detector for Beam Data Measurements
    Stathakis, S.
    Kabat, C.
    Naessig, M.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [5] Evaluation of dynamic phantom for beam profile measurements
    Zhang, Y
    Chu, J
    Bernard, D
    MEDICAL PHYSICS, 2004, 31 (06) : 1886 - 1886
  • [6] Calibration procedure and clinical validation of an high resolution diode array in Tomotherapy
    Ventura, Tiago
    Capela, Miguel
    Silva, Sofia
    Santos, Tania
    Mateus, Josefina
    Lopes, Maria do Carmo
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3331 - S3332
  • [7] Characterization of Sensors and Design of an Embedded Photodetectors Array for Beam Profile Measurements in Radiotherapy
    Mateos, H.
    Lipovetzky, J.
    Alcalde Bessia, F.
    Perez, M.
    Cappagli, P.
    Gomez Berisso, M.
    2017 EIGHT ARGENTINE SYMPOSIUM AND CONFERENCE ON EMBEDDED SYSTEMS (CASE), 2017, : 77 - 82
  • [8] Analytic error model of beam profile evaluation for detector array method
    Xie, Xianchen
    Yang, Pengling
    Zhao, Haichuan
    Wang, Zhenbao
    Zhang, Lei
    FIFTH INTERNATIONAL SYMPOSIUM ON LASER INTERACTION WITH MATTER, 2019, 11046
  • [9] Measuring Patient Cone Beam CT Dose Using a Commercial 4D Diode Array
    Qin, L.
    Alaei, P.
    Zhang, J.
    Chaudhari, S.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [10] Feasibility of using a 2D diode array system for clinical electron beam measurements
    Guo, F. Q.
    Wu, C.
    Stern, R.
    Luo, C.
    Liu, T.
    Shi, J.
    Yang, C.
    Purdy, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2103 - 2104