Frequency of Nd:YAG capsulotomy after implantation of intraocular lenses out of PMMA and silicone

被引:3
|
作者
Pradella, SP [1 ]
Taumer, R [1 ]
机构
[1] Augentagesklin, Frankfurt, Germany
来源
OPHTHALMOLOGE | 1998年 / 95卷 / 07期
关键词
secondary cataract; capsule opacification; silicone; 10L; PMMA;
D O I
10.1007/s003470050301
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The aim of this investigation was to ascertain the frequency of secondary cataract after implantation of PMMA or Silicone IOLs. Patients and methods: In our series of patients we implanted 900 PMMA IOLs in a period of 4 years. In the following 3 years we implanted 1600 silicone IOLs. After the operation, a Nd: YAG laser capsulotomy was indicated there was a reduction in visual acuity and the patient asked for improvement. With the help of computer documentation we had the possibility to follow up a period of 6 years after PMMA and 3 years after silicone IOL implantation. Results: (1) PMMA IOL: After implantation of PMMA IOLs we found a frequency of 22% capsulotomies during the investigation period of 6 years; 4.9% of them occurred during the 1st year and 8% during the 2nd year. (2) Silicone IOL: During the control period of 3 years we found a capsulotomy rate of 9,9%. Most happened in the 1st year. Conclusions: Our 22.9% capsulotomy rate after PMMA IOL implantation is lower than the rate mentioned in the literature. We noticed a peak of capsulotomies in the 2nd year after the operation. During a control period of only 3 years after implantation of silicone IOLs we found a capsulotomy rate of 9.9%.
引用
收藏
页码:482 / 485
页数:6
相关论文
共 50 条
  • [1] Frequency of Nd: YAG capsulotomy after implantation of intraocular lenses out of PMMA and silicone
    Stephan P. Pradella
    Reiner Täumer
    Der Ophthalmologe, 1998, 95 : 482 - 485
  • [2] Neodymium:YAG capsulotomy rates following phacoemulsification with implantation of PMMA, silicone, and acrylic intraocular lenses
    Ram, J
    Kaushik, S
    Brar, GS
    Gupta, A
    OPHTHALMIC SURGERY AND LASERS, 2001, 32 (05): : 375 - 382
  • [3] A comparison of ND:YAG laser damage to acrylic, silicone and PMMA intraocular lenses
    Weaver, YK
    Parrel, JM
    Denham, D
    Clayman, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 3533 - 3533
  • [4] Neodymium:YAG laser posterior capsulotomy after implantation of AcrySof intraocular lenses
    Davison, JA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (07): : 1492 - 1500
  • [5] Neodymium:YAG capsulotomy rates after phacoemulsification with silicone posterior chamber intraocular lenses
    Mamalis, N
    Phillips, B
    Kopp, CH
    Crandall, AS
    Olson, RJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 : 1296 - 1302
  • [6] Incidence of Nd:YAG Capsulotomy After Implantation of AcrySof Multifocal and Monofocal Intraocular Lenses: A Case Controlled Study
    Shah, Vipul C.
    Russo, Christopher
    Cannon, Richard
    Davidson, Richard
    Taravella, Michael J.
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (08) : 565 - 568
  • [7] A COMPARISON OF ND-YAG LASER DAMAGE THRESHOLDS FOR PMMA AND SILICONE INTRAOCULAR LENSES
    BATH, PE
    ROMBERGER, AB
    BROWN, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1986, 27 (05) : 795 - 798
  • [8] Nd:YAG Capsulotomy Rates With Two Trifocal Intraocular Lenses
    Bilbao-Calabuig, Rafael
    Llovet-Osuna, Fernando
    Gonzalez-Lopez, Felix
    Beltran, Jaime
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (11) : 748 - +
  • [9] Nd:YAG Capsulotomy Rates with Two Multifocal Intraocular Lenses
    Bai, Huiran
    Li, Honglei
    Zheng, Simeng
    Sun, Lihong
    Wu, Xiaoming
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 : 8975 - 8980
  • [10] Comparison of Nd:YAG capsulotomy rates following phacoemulsification with implantation of PMMA, silicone, or acrylic intra-ocular lenses in four European countries
    Auffarth, GU
    Brezin, A
    Caporossi, A
    Lafuma, A
    Mendicute, J
    Berdeaux, G
    Smith, AF
    OPHTHALMIC EPIDEMIOLOGY, 2004, 11 (04) : 319 - 329