Effects of Independent Component Analysis on Magnetoencephalography Source Localization in Pre-surgical Frontal Lobe Epilepsy Patients

被引:11
|
作者
Pellegrino, Giovanni [1 ]
Xu, Min [1 ,2 ]
Alkuwaiti, Abdulla [1 ]
Porras-Bettancourt, Manuel [1 ]
Abbas, Ghada [1 ]
Lina, Jean-Marc [3 ,4 ,5 ]
Grova, Christophe [1 ,3 ,4 ,6 ,7 ]
Kobayashi, Eliane [1 ]
机构
[1] McGill Univ, Montreal Neurol Inst, Neurol & Neurosurg Dept, Montreal, PQ, Canada
[2] Wuhan Univ, Dept Geriatr, Zhongnan Hosp, Wuhan, Peoples R China
[3] McGill Univ, Biomed Engn Dept, Multimodal Funct Imaging Lab, Montreal, PQ, Canada
[4] Ecole Technol Super, Dept Genie Elect, Montreal, PQ, Canada
[5] Univ Montreal, Ctr Rech Math, Montreal, PQ, Canada
[6] Concordia Univ, Phys Dept, Montreal, PQ, Canada
[7] Concordia Univ, PERFORM Ctr, Montreal, PQ, Canada
来源
FRONTIERS IN NEUROLOGY | 2020年 / 11卷
基金
加拿大自然科学与工程研究理事会;
关键词
interictal epileptiform discharges; magnetoencephalography; magnetic source imaging; spike; independent component analysis; frontal epilepsy; MEG; source localization; FUNCTIONAL SOURCE SEPARATION; SEIZURE ONSET ZONE; ARTIFACT REMOVAL; CLINICAL UTILITY; FOCAL EPILEPSY; EEG DATA; MEG; RESOLUTION; SURGERY; SPIKES;
D O I
10.3389/fneur.2020.00479
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective:Magnetoencephalography source imaging (MSI) of interictal epileptiform discharges (IED) is a useful presurgical tool in the evaluation of drug-resistant frontal lobe epilepsy (FLE) patients. Yet, failures in MSI can arise related to artifacts and to interference of background activity. Independent component analysis (ICA) is a popular denoising procedure but its clinical application remains challenging, as the selection of multiple independent components (IC) is controversial, operator dependent, and time consuming. We evaluated whether selecting only one IC of interest based on its similarity with the average IED field improves MSI in FLE. Methods:MSI was performed with the equivalent current dipole (ECD) technique and two distributed magnetic source imaging (dMSI) approaches: minimum norm estimate (MNE) and coherent Maximum Entropy on the Mean (cMEM). MSI accuracy was evaluated under three conditions: (1) ICA of continuous data (Cont_ICA), (2) ICA at the time of IED (IED_ICA), and (3) without ICA (No_ICA). Localization performance was quantitatively measured as actual distance of the source maximum in relation to the focus (Dmin), and spatial dispersion (SD) for dMSI. Results:After ICA, ECD Dmin did not change significantly (p> 0.200). For both dMSI techniques, ICA application worsened the source localization accuracy. We observed a worsening of both MNE Dmin (p< 0.05, consistently) and MNE SD (p< 0.001, consistently) for both ICA approaches. A similar behaviour was observed for cMEM, for which, however, Cont_ICA seemed less detrimental. Conclusion:We demonstrated that a simplified ICA approach selecting one IC of interest in combination with distributed magnetic source imaging can be detrimental. More complex approaches may provide better results but would be rather difficult to apply in real-world clinical setting. In a broader perspective, caution should be taken in applying ICA for source localization of interictal activity. To ensure optimal and useful results, effort should focus on acquiring good quality data, minimizing artifacts, and determining optimal candidacy for MEG, rather than counting on data cleaning techniques.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Magnetoencephalography source localization and surgical outcome in temporal lobe epilepsy
    Assaf, BA
    Karkar, KM
    Laxer, KD
    Garcia, PA
    Austin, EJ
    Barbaro, NM
    Aminoff, MJ
    CLINICAL NEUROPHYSIOLOGY, 2004, 115 (09) : 2066 - 2076
  • [2] Is There a Role for Magnetoencephalography in Pre-surgical RNS Implantation in Drug-Resistant Temporal Lobe Epilepsy?
    Alshammaa, Abdullah
    Keating, Ryan
    Baki, Nour
    Mahajan, Abhimanyu
    Barkley, Gregory
    Zillgitt, Andrew
    Bowyer, Susan
    NEUROLOGY, 2019, 92 (15)
  • [3] Health-related quality of life in pre-surgical temporal lobe epilepsy patients
    Lehrner, J
    Baumgartner, C
    Serles, W
    Olbrich, A
    Pataraia, E
    Aull, S
    Bacher, J
    Deecke, L
    QUALITY OF LIFE RESEARCH, 1997, 6 (7-8) : 219 - 219
  • [4] Pre-surgical neuropsychological functioning of selected right and left temporal lobe epilepsy patients
    Schoenberg, M. R.
    Reese, L.
    Dawson, K.
    Werz, M.
    Maciunas, R.
    ARCHIVES OF CLINICAL NEUROPSYCHOLOGY, 2006, 21 (06) : 524 - 525
  • [5] Pre-surgical language deficits in left temporal lobe epilepsy compared to right temporal lobe epilepsy
    Schoenberg, M. R.
    Mash, K. M.
    Koubeissi, M. Z.
    Maciunas, R. J.
    Griffith, T. R.
    Koubeissi, M. Z.
    Syed, T. U.
    Amina, S.
    Lueders, H.
    ARCHIVES OF CLINICAL NEUROPSYCHOLOGY, 2008, 23 (06) : 741 - 742
  • [6] PSYCHIATRIC ASSESSMENT OF PRE-SURGICAL EPILEPSY PATIENTS
    Tesar, George E. E.
    EPILEPSIA, 2009, 50 : 69 - 69
  • [7] Pre-surgical Verbal Fluency Performance of Selected Right and Left Temporal Lobe Epilepsy Patients
    Mattingly, M.
    Rinehardt, E.
    Benbadis, S.
    Borzog, A.
    Rogers-Neame, N.
    Vale, F.
    Frontera, A.
    Schoenberg, M.
    ARCHIVES OF CLINICAL NEUROPSYCHOLOGY, 2010, 25 (06) : 565 - 565
  • [8] Magnetic source imaging for pre-surgical lateralization of refractory epilepsy
    Carlson, Chad
    Schevon, Catherine
    Stout, Jeff
    Nadkami, Siddhartha
    Doyle, Werner
    Weiner, Howard
    Pacia, Steven
    Devinsky, Orrin
    Kuzniecky, Ruben
    EPILEPSIA, 2006, 47 : 4 - 5
  • [9] A Computational Tool for Pre-Surgical Evaluation of Epilepsy Patients
    Jordan, A.
    Subramanian, S.
    Hao, S.
    2014 40TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC), 2014,
  • [10] The role of diffusion tensor imaging in the pre-surgical study of temporal lobe epilepsy
    Garcia-Pallero, M. Angeles
    Torres, Cristina V.
    Manzanares-Soler, Rafael
    Camara, Estela
    Sola, Rafael G.
    REVISTA DE NEUROLOGIA, 2016, 63 (12) : 537 - 542