Purpose: To assess whether short-term soft contact lens wear alters the anterior eye surface. Methods: Twenty-two neophyte subjects wore soft contact lenses for a period of five hours. Topography based corneo-scleral limbal radius estimates were derived from height measurements acquired with a corneo-scleral profilometer. Additionally, central corneal thickness (CCT), anterior chamber depth (ACD), corneal curvature radius (R) and white-to-white (WTW) diameter were acquired with an OCT-assisted biometer. Measurements were obtained without lens wear (baseline), immediately after lens removal following five hours of wear and three hours after lens removal. Results: Short-term soft contact lens wear significantly modifies corneo-scleral limbal radius (mean +/- SD: 130 +/- 74 mu m, p< < 0.001) and the changes are repeatable. In contrast, the WTW diameter and R were not modified. ACD and CCT were significantly affected but no significant correlations were found between the increment of the limbal radius and the decrease in ACD and CCT. Limbal radius increment was reversed three hours after lens removal for 68% of the subjects but the time course of this reversal was not uniform. Conclusions: It is possible to accurately quantify limbal radius changes as a consequence of soft contact lens wear. The increment in the limbal diameter could reach over 0.5 mm but that alteration does not correspond to changes in WTW diameter and it was not observable to the examiner using a slit lamp. Assessing topographical limbus after contact lens wear could be a tool to optimize the selection of the contact lens, from the perspective of anterior eye surface changes.
引用
收藏
页码:293 / 300
页数:8
相关论文
共 50 条
  • [1] The role of corneo-scleral junction in soft contact lens fitting: Case report on nanophthalmos
    Kumar, Preetam
    Woretaw, Haile
    CONTACT LENS & ANTERIOR EYE, 2019, 42 (02): : 226 - 228
  • [2] Pellucid marginal degeneration: Role of corneo-scleral contact lens fitting
    Boukari, M.
    Kallel, H.
    Kaouel, H.
    Errais, K.
    Ammous, I.
    Zhioua, R.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2020, 43 (02): : E85 - E87
  • [3] Corneal tissue changes following short-term soft contact lens wear of different materials
    Consejo, Alejandra
    Trillo-Moreno, Irene
    Remon, Laura
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2023, 43 (01) : 35 - 45
  • [4] Corneal changes following short-term miniscleral contact lens wear
    Vincent, Stephen J.
    Alonso-Caneiro, David
    Collins, Michael J.
    CONTACT LENS & ANTERIOR EYE, 2014, 37 (06): : 461 - 468
  • [5] Corneal changes following short-term rigid contact lens wear
    Tyagi, Garima
    Collins, Michael J.
    Read, Scott A.
    Davis, Brett A.
    CONTACT LENS & ANTERIOR EYE, 2012, 35 (03): : 129 - 136
  • [6] Corneo-scleral contact lens in a piggyback system for keratoconus: A case report
    Porcar, Esteban
    Carlos Montalt, Juan
    Espana-Gregori, Enrique
    Peris-Martinez, Cristina
    CONTACT LENS & ANTERIOR EYE, 2017, 40 (03): : 190 - 194
  • [7] Changes in Scleral Tonometry and Anterior Chamber Angle after Short-term Scleral Lens Wear
    Obinwanne, Chukwuemeka Junior
    Echendu, Damian C.
    Agbonlahor, Osazee
    Dike, Stella
    OPTOMETRY AND VISION SCIENCE, 2020, 97 (09) : 720 - 725
  • [8] Tissue compression following short-term miniscerlal contact lens wear
    Vincent, Stephen J.
    Alonso-Caneiro, David
    Collins, Michael J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [9] Short-term Results of Using Lamellar Corneo-scleral Patch Graft for the Ahmed Glaucoma Valve Implant Surgery
    Dennis S.C.Lam
    Wah Cheuk
    Jimmy S.M.Lai
    眼科学报, 1997, (03) : 109 - 112
  • [10] Acute and short-term changes in visual function with multifocal soft contact lens wear in young adults
    Kang, Pauline
    Wildsoet, Christine F.
    CONTACT LENS & ANTERIOR EYE, 2016, 39 (02): : 133 - 140