Reliability of the Vascular Claudication Reporting in Diabetic Patients With Peripheral Arterial Disease: A Study With Near-Infrared Spectroscopy

被引:23
|
作者
Manfredini, Fabio [1 ,2 ]
Lamberti, Nicola [1 ]
Malagoni, Anna Maria [1 ,3 ]
Zambon, Christel [1 ]
Basaglia, Nino [2 ]
Mascoli, Francesco [1 ]
Manfredini, Roberto [1 ,4 ]
Zamboni, Paolo [1 ,3 ]
机构
[1] Univ Ferrara, Vasc Dis Ctr, I-44100 Ferrara, Italy
[2] S Anna Hosp Univ, Dept Rehabil Med, Ferrara, Italy
[3] S Anna Hosp Univ, Program Pathophysiol Vasc Peripheral Syst & Day S, Ferrara, Italy
[4] Univ Ferrara, Dept Med Sci, Clin Med, I-44124 Ferrara, Italy
关键词
diabetes; exercise tests; near-infrared spectroscopy; peripheral arterial disease; pain perception; SKELETAL-MUSCLE OXYGENATION; INTERMITTENT CLAUDICATION; ELDERLY SUBJECTS; EXERCISE; FATIGUE; WALKING; INTOLERANCE; DYNAMICS; KINETICS; BALANCE;
D O I
10.1177/0003319714534762
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
We evaluated whether altered reporting of ischemic symptoms occurs in diabetic patients with peripheral arterial disease (PAD) and stable claudication. Patients (n = 152) with claudication were enrolled (120 males; mean age: 71.0 +/- 8.6 years): 74 with diabetes (DM-PAD) and 78 without (DMfree-PAD). The degree of muscle oxygenation at symptom onset and maximal speed (Smax) during an incremental treadmill test was recorded at the gastrocnemius by near-infrared spectroscopy (NIRS) and quantified by area under the curve of oxygenated hemoglobin (AUC-Hbo(2)) and area under the curve of differential hemoglobin (AUC-dHb). The DM-PAD and DMfree-PAD showed similar exercise capacities inversely correlated with the degree of muscle oxygenation but significantly lower values of AUC-Hbo(2) and AUC-dHb for DM-PAD at symptom onset and Smax (-356 vs -122 and -1200 vs -359, P < .0001). During a NIRS-assisted test, the report of claudication in the presence of diabetes was delayed, occurring at a lower degree of oxygenation than in patients with PAD only, with potential implications for testing, functional staging, and balance disorders.
引用
收藏
页码:365 / 374
页数:10
相关论文
共 50 条
  • [1] Quantitative near-infrared spectroscopy on patients with peripheral vascular disease
    Franceschini, MA
    Fantini, S
    Palumbo, R
    Pasqualini, L
    Vaudo, G
    Franceschini, E
    Gratton, E
    Palumbo, B
    Innocente, S
    Mannarino, E
    PHOTON PROPAGATION IN TISSUES III, PROCEEDINGS OF, 1998, 3194 : 112 - 115
  • [2] NEAR-INFRARED SPECTROSCOPY IN PERIPHERAL VASCULAR-DISEASE
    CHEATLE, TR
    POTTER, LA
    COPE, M
    DELPY, DT
    SMITH, PDC
    SCURR, JH
    BRITISH JOURNAL OF SURGERY, 1991, 78 (04) : 405 - 408
  • [3] Near infrared spectroscopy-guided exercise training for claudication in peripheral arterial disease
    Murrow, Jonathan R.
    Brizendine, Jared T.
    Djire, Bill
    Young, Hui-Ju
    Rathbun, Stephen
    Nilsson, Kent R., Jr.
    McCully, Kevin K.
    EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2019, 26 (05) : 471 - 480
  • [4] A Dynamic Objective Evaluation of Peripheral Arterial Disease by Near-Infrared Spectroscopy
    Manfredini, F.
    Malagoni, A. M.
    Felisatti, M.
    Mandini, S.
    Mascoli, F.
    Manfredini, R.
    Basaglia, N.
    Zamboni, P.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2009, 38 (04) : 441 - 448
  • [5] Novel Near-Infrared Spectroscopy-Guided Treadmill Exercise Training Associated with Improvements in Claudication Among Subjects with Peripheral Arterial Disease
    Murrow, Jonathan
    Brizendine, Jared
    Djire, Bill
    Young, Hui-Ju
    McCully, Kevin K.
    CIRCULATION, 2014, 130
  • [6] Near-infrared spectroscopy with a provocative maneuver to detect the presence of severe peripheral arterial disease
    Reiter, Homer-Christian J.
    Andersen, Charles A.
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2024, 10 (06):
  • [7] Near-infrared spectroscopy, scintigraphy and transcutaneous oximetry in the diagnosis of peripheral arterial disease.
    Pasqualini, L
    Vaudo, G
    Fantini, S
    Franceschini, MA
    Paoletti, F
    Innocente, S
    Palumbo, R
    Mannarino, E
    ATHEROSCLEROSIS, 1997, 135 : S17 - S17
  • [8] Near-infrared spectroscopy measure of limb peripheral perfusion in neonatal arterial thromboembolic disease
    Milan, A.
    Freato, F.
    Vanzo, V.
    Camporese, G.
    Baraldi, M.
    Chiandetti, L.
    Zaramella, P.
    MINERVA PEDIATRICA, 2012, 64 (06) : 633 - 639
  • [9] Near-infrared spectroscopy for evaluation of peripheral vascular disease. A systematic review of literature
    Vardi, M.
    Nini, A.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2008, 35 (01) : 68 - 74
  • [10] Invasive Characterization of Atherosclerotic Plaque in Patients with Peripheral Arterial Disease Using Near-Infrared Spectroscopy Intravascular Ultrasound
    Abbas, Amr E.
    Zacharias, Sibin K.
    Goldstein, James A.
    Hanson, Ivan D.
    Safian, Robert D.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (03) : 461 - 470