IMPROVED CHAMBER SYSTEMS FOR RAPID, REAL-TIME NITROUS OXIDE EMISSIONS FROM MANURE AND SOIL

被引:17
|
作者
Parker, D. B. [1 ]
Casey, K. D. [2 ]
Todd, R. W. [1 ]
Waldrip, H. M. [1 ]
Marek, G. W. [1 ]
Auvermann, B. W. [2 ]
Marek, T. H. [2 ]
Webb, K. [1 ]
Willis, W. M. [1 ]
Pemberton, B. [2 ]
Meyer, B. [1 ]
机构
[1] ARS, USDA, CPRL, 2300 Expt Stn Rd, Bushland, TX 79012 USA
[2] Texas A&M AgriLife Res, Amarillo, TX USA
关键词
Cattle; Chamber; Diurnal; Fan; Feedlot; Greenhouse gas; Manure; Precision; BEEF-CATTLE FEEDLOT; GREENHOUSE-GAS; SAMPLING FREQUENCY; METHANE EMISSIONS; FIELD MEASUREMENT; N2O EMISSIONS; FLUX; CH4; DENITRIFICATION; AMMONIA;
D O I
10.13031/trans.12151
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Nitrous oxide (N2O) emission rates have traditionally been measured using non-flow-through (NFT), nonsteady-state (NSS) chambers, which rely on measuring the increase in N2O concentration in the sealed chamber headspace over time. These flux measurements are very labor-and time-intensive, requiring three to four gas samples collected over a 30 to 60 min period, followed by laboratory N2O measurement with a gas chromatograph (GC) and subsequent flux rate calculation. The objective of this research was to develop and evaluate improved, real-time flux chamber designs that rapidly quantify N2O emissions from manure and soil. The first chamber system consisted of six square 0.95 m(2) chamber pans. The chamber pans were mounted on a rail system to facilitate controlled indoor/outdoor laboratory research at a pilot scale. An aluminum lid was moved among the chamber pans. A second portable chamber system with a circular footprint (0.49 m internal dia.) was designed for use in field measurements. With both systems, N2O concentrations were measured each second with 0.1 ppb resolution by recirculating sample air through a real-time continuous N2O analyzer with return flow into the recirculating-flow-through (RFT-NSS) chamber. Performance and observational data are presented for different chamber vent designs, sealing mechanisms between the chamber pan and lid, recirculation pumps, and presence/absence of an internal fan that mixes headspace air within the sealed chamber. As examples of the repeatability and precision of the methodology, ten consecutive flux measurements were obtained using moist manure (32.6% wet basis water content, WCWB) within a 15 min period in which chamber pans were fitted with lids for 60 s and removed for 30 s. The mean calculated N2O flux was 43.08 +/- 0.89 mg N2O m(-2) h(-1). Using dry manure (WCWB = 10.8%), five consecutive flux measurements showed a very low, but consistent, flux that averaged 0.025 +/- 0.0016 mg N2O m(-2) h(-1). Five case study experiments demonstrate the usefulness of these chamber systems and highlight discoveries and lessons learned to enhance future research efforts. Major discoveries and observations include: (1) installation of a small internal fan within the chamber lids decreased N2O fluctuation over small time periods, allowing precise measurement of manure N2O fluxes as low as 0.0073 mg N2O m(-2) h(-1) during a 60 s measurement period; (2) two distinct N2O peaks were observed at 1 and 21 d following the addition of water to manure (initial WCWB = 32.6%), with the second peak accounting for 83% of the total N2O emitted over 45 d; and (3) there was notable diurnal variation in N2O fluxes due to temperature variation, even when the manure was dry (WCWB = 10.8%). These flux chamber systems proved to be more rapid, precise, and repeatable than traditional flux chamber methods and offer promise for future greenhouse gas emissions research on manure and soil.
引用
收藏
页码:1235 / 1258
页数:24
相关论文
共 50 条
  • [1] Nitrous oxide and methane emissions from soil–plant systems
    G.X. Chen
    G.H. Huang
    B. Huang
    K.W. Yu
    J. Wu
    H. Xu
    Nutrient Cycling in Agroecosystems, 1997, 49 : 41 - 45
  • [2] Emissions of nitrous oxide from soil
    Pathak, H
    CURRENT SCIENCE, 1999, 77 (03): : 359 - 369
  • [3] Nitrous Oxide Emissions from Dairy Manure Compost
    Maeda, Koki
    JARQ-JAPAN AGRICULTURAL RESEARCH QUARTERLY, 2015, 49 (01): : 17 - 21
  • [4] Predicting nitrous oxide emissions from manure properties and soil moisture: An incubation experiment
    Baral, Khagendra R.
    Arthur, Emmanuel
    Olesen, Jorgen E.
    Petersen, Soren O.
    SOIL BIOLOGY & BIOCHEMISTRY, 2016, 97 : 112 - 120
  • [5] Soil nitrous oxide emissions in forage systems fertilized with liquid dairy manure and inorganic fertilizers
    Lazcano, Cristina
    Tsang, Alia
    Doane, Timothy A.
    Pettygrove, G. Stuart
    Horwath, William R.
    Burger, Martin
    AGRICULTURE ECOSYSTEMS & ENVIRONMENT, 2016, 225 : 160 - 172
  • [6] Comparison of field measurement methods of nitrous oxide soil emissions: from the chamber to the vial
    Noemi Cosentino, Vanina Rosa
    Ingrid Romaniuk, Romina
    Maria Lupi, Ana
    Manuel Gomez, Federico
    Rimski Korsakov, Helena
    Rosa Alvarez, Carina
    Ciarlo, Esteban
    REVISTA BRASILEIRA DE CIENCIA DO SOLO, 2020, 44 : 1 - 9
  • [7] Nitrous oxide and methane emissions from soil-plant systems
    Chen, GX
    Huang, GH
    Huang, B
    Yu, KW
    Wu, J
    Xu, H
    NUTRIENT CYCLING IN AGROECOSYSTEMS, 1997, 49 (1-3) : 41 - 45
  • [8] Green waste compost reduces nitrous oxide emissions from feedlot manure applied to soil
    Dalal, Ram C.
    Gibson, Iain
    Allen, Diane E.
    Menzies, Neal W.
    AGRICULTURE ECOSYSTEMS & ENVIRONMENT, 2010, 136 (3-4) : 273 - 281
  • [9] Nitrous Oxide Emissions from a Clay Soil Receiving Granular Urea Formulations and Dairy Manure
    Asgedom, Haben
    Tenuta, Mario
    Flaten, Donald N.
    Gao, Xiaopeng
    Kebreab, Ermias
    AGRONOMY JOURNAL, 2014, 106 (02) : 732 - 744
  • [10] Influence of Liquid Manure on Soil Denitrifier Abundance, Denitrification, and Nitrous Oxide Emissions
    Miller, M. N.
    Zebarth, B. J.
    Dandie, C. E.
    Burton, D. L.
    Goyer, C.
    Trevors, J. T.
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2009, 73 (03) : 760 - 768