Research on new spectral reconstruction solutions for Fourier-transform spectrometer

被引:0
|
作者
Li, Suning [1 ]
Zhu, Rihong [1 ]
Li, Jianxin [1 ]
机构
[1] Nanjing Univ Sci & Technol, Dept Opt Engn, Sch Elect Informat & Opt Engn, Nanjing, Jiangsu Prov, Peoples R China
关键词
imaging spectroscopy; reconstruction; spectrum; Fourier transform; Hilbert transform; conjugated correction; DISCRETE COSINE TRANSFORM; IMAGING SPECTROMETER; SPECTROSCOPY; DCT;
D O I
暂无
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The spectral reconstruction of Fourier transform spectrometer can be simply achieved by using a Fourier transform or a Fourier cosine transform. However, the traditional Fourier transform solution is carried out in the complex-number field and the result is also a complex-number sequence, which will introduce an extra-phase to the spectrum and lead to the inaccuracy of reconstructed spectral intensity. On the other hand, although researchers use a Fourier cosine transform to avoid the extra-phase problem effectively, this solution has a boundary condition problem which cannot be avoided and may also lead to the inaccuracy of the reconstructed spectral intensity. To solve the problem, an improved Hilbert transform reconstruction solution (IHTRS) and a Fourier conjugated correction reconstruction solution (FCCRS) are developed by analyzing traditional reconstruction solutions. The main thought of IHTRS is using a complex-number sequence to represent the real-number signal, doing the transform in the complex-number field, and extracting the real-number spectrum from the transform result in the end. The main thought of FCCRS is constraining the transform process in the real-number field, using the conjugated property of the Fourier transform, creating the conjugated symmetrical form of the original signal first and acquiring the conjugated symmetrical form of the real spectrum, and extracting the real spectrum from it in the end. The results of the two solutions are compared. By carrying out both the simulation and the experiment using a helium lamp, it can be concluded that the FCCRS is 3 times faster than IHTRS, while the reconstructed spectral intensity accuracy of IHTRS is 29% higher than FCCRS. Both of the two solutions can avoid either the extra-phase problem caused by a discrete Fourier transform (DFT) solution or the boundary condition caused by a discrete cosine transform (DCT) solution effectively and improve the reconstructed spectral intensity accuracy.
引用
收藏
页码:121 / 133
页数:13
相关论文
共 50 条
  • [1] Spectral Reconstruction for High Spectral Resolution in a Static Modulated Fourier-transform Spectrometer
    Cho, Ju Yong
    Lee, Seunghoon
    Kim, Hyoungjin
    Jang, Won Kweon
    CURRENT OPTICS AND PHOTONICS, 2022, 6 (03) : 244 - 251
  • [2] A Fourier-transform spectrometer for spectral-irradiance comparisons
    Werner, L
    METROLOGIA, 1996, 32 (06) : 531 - 534
  • [3] WIDE SPECTRAL RANGE IR FOURIER-TRANSFORM SPECTROMETER FOR ATMOSPHERIC RESEARCH FROM SPACECRAFT
    GORBUNOV, GG
    ILJUHIN, VN
    ECONOMOV, AP
    MOSHKIN, BE
    GEOMAGNETIZM I AERONOMIYA, 1994, 34 (05): : 200 - 204
  • [4] An improved spectral reconstruction method for Fourier transform spectrometer
    Zhang, P. (eiqd@ei41.com), 1600, Chinese Optical Society (33):
  • [5] Fourier Transform Spectrometer Using Spectral Reconstruction Theory
    Zhu Shuyuan
    Wu Penghan
    Lu Zhenzhen
    Dong Jingran
    Feng Jihong
    LASER & OPTOELECTRONICS PROGRESS, 2023, 60 (09)
  • [6] FOURIER-TRANSFORM DIELECTRIC SPECTROMETER
    JOHNSON, GE
    ANDERSON, EW
    LINK, GL
    MCCALL, DW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (03): : 266 - 266
  • [7] DIFFRACTION IN A FOURIER-TRANSFORM SPECTROMETER
    SALONEN, KI
    SALOMAA, IK
    KAUPPINEN, JK
    APPLIED OPTICS, 1995, 34 (07): : 1190 - 1196
  • [8] A FOURIER-TRANSFORM VISIBLE SPECTROMETER
    ZHANG, ZL
    ZHENG, P
    LIN, Z
    MIKROCHIMICA ACTA, 1988, 2 (1-6) : 329 - 333
  • [9] STATIONARY FOURIER-TRANSFORM SPECTROMETER
    JUNTTILA, ML
    APPLIED OPTICS, 1992, 31 (21): : 4106 - 4112
  • [10] FOURIER-TRANSFORM PHOTOACOUSTIC SPECTROMETER
    LLOYD, LB
    RISEMAN, SM
    BURNHAM, RK
    EYRING, EM
    FARROW, MM