A Robust Methodology for In Vivo T1 Mapping

被引:169
|
作者
Barral, Joelle K. [1 ]
Gudmundson, Erik [2 ]
Stikov, Nikola [1 ]
Etezadi-Amoli, Maryam [1 ]
Stoica, Petre [2 ]
Nishimura, Dwight G. [1 ]
机构
[1] Stanford Univ, Dept Elect Engn, Magnet Resonance Syst Res Lab, Stanford, CA 94305 USA
[2] Uppsala Univ, Syst & Control Div, Dept Informat Technol, Uppsala, Sweden
基金
欧洲研究理事会; 瑞典研究理事会;
关键词
T-1; mapping; relaxometry; nonlinear least squares; brain imaging; skin imaging; RELAXATION-TIMES; MAGNETIZATION-TRANSFER; TISSUE; MRI; TEMPERATURE; DEPENDENCE; SKIN; T1; PARAMETERS; FREQUENCY;
D O I
10.1002/mrm.22497
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this article, a robust methodology for in vivo T-1 mapping is presented. The approach combines a gold standard scanning procedure with a novel fitting procedure. Fitting complex data to a five-parameter model ensures accuracy and precision of the T-1 estimation. A reduced-dimension nonlinear least squares method is proposed. This method turns the complicated multi-parameter minimization into a straightforward one-dimensional search. As the range of possible T-1 values is known, a global grid search can be used, ensuring that a global optimal solution is found. When only magnitude data are available, the algorithm is adapted to concurrently restore polarity. The performance of the new algorithm is demonstrated in simulations and phantom experiments. The new algorithm is as accurate and precise as the conventionally used Levenberg-Marquardt algorithm but much faster. This gain in speed makes the use of the five-parameter model viable. In addition, the new algorithm does not require initialization of the search parameters. Finally, the methodology is applied in vivo to conventional brain imaging and to skin imaging. T-1 values are estimated for white matter and gray matter at 1.5T and for dermis, hypodermis, and muscle at 1.5T, 3T, and 7T. Magn Reson Med 64:1057-1067, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1057 / 1067
页数:11
相关论文
共 50 条
  • [1] Adiabatic spin-lock preparations enable robust in vivo cardiac T1ρ-mapping at 3T
    Coletti, Chiara
    Tourais, Joao
    Ploeml, Telly
    van de Steeg-Henzen, Christal
    Akcakaya, Mehmet
    Weingartner, Sebastian
    2022 44TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2022, : 1690 - 1693
  • [2] Uncertainty estimations for quantitative in vivo MRI T1 mapping
    Polders, Daniel L.
    Leemans, Alexander
    Luijten, Peter R.
    Hoogduin, Hans
    JOURNAL OF MAGNETIC RESONANCE, 2012, 224 : 53 - 60
  • [3] Robust motion correction for cardiac T1 and ECV mapping using a T1 relaxation model approach
    Tilborghs, Sofie
    Dresselaers, Tom
    Claus, Piet
    Claessen, Guido
    Bogaert, Jan
    Maes, Frederik
    Suetens, Paul
    MEDICAL IMAGE ANALYSIS, 2019, 52 : 212 - 227
  • [4] Accurate and robust systolic myocardial T1 mapping using saturation recovery with individualized delay time: comparison with diastolic T1 mapping
    Arai H.
    Kawakubo M.
    Sanui K.
    Nishimura H.
    Kadokami T.
    Radiological Physics and Technology, 2018, 11 (4) : 415 - 422
  • [5] In vivo T1 mapping of neonatal brain tissue at 64 mT
    Padormo, Francesco
    Cawley, Paul
    Dillon, Louise
    Hughes, Emer
    Almalbis, Jennifer
    Robinson, Joanna
    Maggioni, Alessandra
    De La Fuente Botella, Miguel
    Cromb, Dan
    Price, Anthony
    Arlinghaus, Lori
    Pitts, John
    Luo, Tianrui
    Zhang, Dingtian
    Deoni, Sean C. L.
    Williams, Steve
    Malik, Shaihan
    O'Muircheartaigh, Jonathan
    Counsell, Serena J.
    Rutherford, Mary
    Arichi, Tomoki
    Edwards, A. David
    Hajnal, Joseph V.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (03) : 1016 - 1025
  • [6] Biexponential T1ρ relaxation mapping of human knee cartilage in vivo at 3 T
    Sharafi, Azadeh
    Xia, Ding
    Chang, Gregory
    Regatte, Ravinder R.
    NMR IN BIOMEDICINE, 2017, 30 (10)
  • [7] Phantom and in vivo study of the Look-Locher T1 mapping method
    Karlsson, M
    Nordell, B
    MAGNETIC RESONANCE IMAGING, 1999, 17 (10) : 1481 - 1488
  • [8] T1ρ-relaxation mapping of human femoral-tibial cartilage in vivo
    Regatte, RR
    Akella, SVS
    Wheaton, AJ
    Borthakur, A
    Kneeland, JB
    Reddy, R
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (03) : 336 - 341
  • [9] Fast and reproducible in vivo T1 mapping of the human cervical spinal cord
    Battiston, Marco
    Schneider, Torben
    Prados, Ferran
    Grussu, Francesco
    Yiannakas, Marios C.
    Ourselin, Sebastien
    Wheeler-Kingshott, Claudia A. M. Gandini
    Samson, Rebecca S.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (04) : 2142 - 2148
  • [10] A T1 and ECV phantom for global T1 mapping quality assurance: The T1 mapping and ECV standardisation in CMR (T1MES) program
    Gaby Captur
    Peter Gatehouse
    Peter Kellman
    Friso G Heslinga
    Katy Keenan
    Ruediger Bruehl
    Marcel Prothmann
    Martin J Graves
    Amedeo Chiribiri
    Bernd Ittermann
    Wenjie Pang
    Reza Nezafat
    Michael Salerno
    James C Moon
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)