A novel and secure technique of stemmed acetabular cup implantation in complex hip reconstructions: a comparative study and technical note

被引:2
|
作者
Mallet, Julien [1 ]
Persigant, Mike [1 ]
Quinette, Yonis [1 ]
Brulefert, Kevin [1 ]
Waast, Denis [1 ]
Vaz, Gualter [2 ]
Nich, Christophe [1 ,3 ]
Gouin, Francois [1 ,2 ,3 ]
Crenn, Vincent [1 ,3 ]
机构
[1] Univ Hosp Hotel Dieu, Orthopaed & Trauma Dept, UHC Nantes, 1 Pl Alexis Ricordeau, F-44093 Nantes 1, France
[2] Leon Berard Canc Ctr, Dept Surg, Lyon, France
[3] INSERM UMR 1238, Bone Sarcomas & Remodelling Calcified Tissues, Fac Med, 1 Rue Gaston Veil, F-44035 Nantes 1, France
关键词
Hip arthroplasty; Coned stemmed acetabular cup; Ice cream cup; Acetabular defect; CREAM CONE PROSTHESIS; ENDOPROSTHETIC RECONSTRUCTION; RESECTION; ARTHROPLASTY;
D O I
10.1007/s00264-021-05224-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The stemmed acetabular cup (SAC) can be considered in several complicated situations. This type of prosthesis uses the iliac isthmus, which is most often preserved, thus allowing solid anchorage. Its implantation is prone to mechanical complications intraoperatively, such as extra-isthmic effraction, fracture, and early aseptic loosening. The aim of our study was to compare a new technique using a flexible motorized reamer combined with isthmus catheterization (Group A) versus the standard technique deploying a rigid reamer alone (Group B). Materials and methods A retrospective analysis was carried out of the SACs implanted at our hospital. The main evaluation criterion was visualization of extra-isthmic effraction (EIE) of the stem. Results Fifty-six SACs (Integra Lepine (R), Genay, France) were implanted, 31 in group A and 25 in group B. The mean follow-up was 21.6 months +/- 22.3. This study found fewer EIEs using a flexible motorized reamer (0 versus 5, p = 0.014), less perioperative bleeding (p = 0.054), and less aseptic loosening in group A (p = 0.034). There was no difference in terms of infection or other mechanical complications post-operatively between the two groups. Conclusion Using iliac catheterization combined with a flexible motorized reamer when implanting a SAC helps to avoid EIE and it also appears to reduce complications such as peri-operative bleeding and early aseptic loosening. We recommend use of this surgical technique rather than a rigid reamer alone, and this new technique should allow widespread and more accessible use of this specific type of implant.
引用
收藏
页码:497 / 505
页数:9
相关论文
共 18 条
  • [1] A novel and secure technique of stemmed acetabular cup implantation in complex hip reconstructions: a comparative study and technical note
    Julien Mallet
    Mike Persigant
    Yonis Quinette
    Kevin Brulefert
    Denis Waast
    Gualter Vaz
    Christophe Nich
    François Gouin
    Vincent Crenn
    International Orthopaedics, 2022, 46 : 497 - 505
  • [2] A laser guide technique: a novel method for accurate acetabular cup alignment in total hip arthroplasty
    Yusuke Kohno
    Tetsuro Nakamura
    Masanori Fujii
    Satoshi Shin
    Toshihiko Hara
    Scientific Reports, 12
  • [3] A laser guide technique: a novel method for accurate acetabular cup alignment in total hip arthroplasty
    Kohno, Yusuke
    Nakamura, Tetsuro
    Fujii, Masanori
    Shin, Satoshi
    Hara, Toshihiko
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [4] Revision of the Birmingham Hip Resurfacing cup: technical notes and the use of a novel technique to overcome unique problems
    Sandiford, N. A.
    Kabir, C.
    Muirhead-Allwood, S. K.
    Skinner, J.
    Nuthall, T.
    HIP INTERNATIONAL, 2008, 18 (03) : 220 - 223
  • [5] ANATOMICAL BASIS FOR STUDY OF ACETABULAR MIGRATION OF THE PROSTHETIC CUP USED IN ARTHROPLASTY OF THE HIP - A NEW TECHNIQUE FOR MEASUREMENT OF MIGRATION
    COLLET, C
    GROSDIDIER, G
    COUDANE, H
    BORRELLY, J
    ANATOMIA CLINICA, 1985, 7 (03): : 171 - 173
  • [6] Cementless cup anchorage in total hip systems - Comparative study of three different acetabular components with titanium surfaces
    Thomsen, M
    Schneider, U
    Blasius, K
    Cona, H
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1995, 133 (06): : 551 - 557
  • [7] Computer-assisted surgery for acetabular cup positioning in total hip arthroplasty: comparative prospective randomized study
    Parratte, S.
    Argenson, J.-N.
    Flecher, X.
    Aubaniac, J.-M.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2007, 93 (03): : 238 - 246
  • [8] Acetabular cup migration after primary cementless total hip arthroplasty in rheumatoid arthritis and its influencing factors: a comparative study with osteoarthritic hip
    Moon, Jun-Ki
    Jung, Ji-Won
    Kim, Yeesuk
    Yang, Jae-Hyuk
    Park, Ye-Soo
    Kim, Young-Ho
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (06) : 1047 - 1053
  • [9] Acetabular cup migration after primary cementless total hip arthroplasty in rheumatoid arthritis and its influencing factors: a comparative study with osteoarthritic hip
    Jun-Ki Moon
    Ji-Won Jung
    Yeesuk Kim
    Jae-Hyuk Yang
    Ye-Soo Park
    Young-Ho Kim
    International Orthopaedics, 2020, 44 : 1047 - 1053
  • [10] Study of Polymorphs of Progesterone by Novel Melt Sonocrystallization Technique: A Technical Note
    Tripathi, R.
    Biradar, Shailesh V.
    Mishra, B.
    Paradkar, Anant R.
    AAPS PHARMSCITECH, 2010, 11 (03): : 1493 - 1498