Pipette tip solid-phase extraction and gas chromatography mass spectrometry for the determination of methamphetamine and amphetamine in human whole blood

被引:44
|
作者
Hasegawa, Chika
Kumazawa, Takeshi
Lee, Xiao-Pen
Marumo, Akemi
Shinmen, Natsuko
Seno, Hiroshi
Sato, Keizo
机构
[1] Showa Univ, Sch Med, Dept Legal Med, Shinagawa Ku, Tokyo 1428555, Japan
[2] Aichi Med Univ, Sch Med, Dept Legal Med, Aichi 4801195, Japan
关键词
solid-phase extraction (SPE); methamphetamine; amphetamine; gas chromatography; mass spectrometry;
D O I
10.1007/s00216-007-1460-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Methamphetamine and amphetamine were extracted from human whole blood samples using pipette tip solid-phase extraction (SPE) with MonoTip C-18 tips, on which C-18-bonded monolithic silica gel was fixed. Human whole blood (0.1 mL) containing methamphetamine and amphetamine, with N-methylbenzylamine as an internal standard, was mixed with 0.4 mL of distilled water and 50 mu L of 5 M sodium hydroxide solution. After centrifugation, the supernatant was extracted to the C-18 phase of the tip (pipette tip volume, 200 mu L) by 25 repeated aspirating/dispensing cycles using a manual micropipettor. Analytes retained in the C-18 phase were eluted with methanol by five repeated aspirating/dispensing cycles. After derivatization with trifluoroacetic anhydride, analytes were measured by gas chromatography - mass spectrometry with selected ion monitoring in the positive-ion electron impact mode. Recoveries of methamphetamine and amphetamine spiked into whole blood were more than 87.6 and 81.7%, respectively. Regression equations for methamphetamine and amphetamine showed excellent linearity in the range of 0.5-100 ng/0.1 mL. The limits of detection for methamphetamine and amphetamine were 0.15 and 0.11 ng/0.1 mL, respectively. Intra- and interday coefficients of variation for both stimulants were not greater than 9.6 and 13.8%, respectively. The determination of methamphetamine and amphetamine in autopsy whole blood samples is presented, and was shown to validate the present methodology.
引用
收藏
页码:563 / 570
页数:8
相关论文
共 50 条
  • [1] Pipette tip solid-phase extraction and gas chromatography – mass spectrometry for the determination of methamphetamine and amphetamine in human whole blood
    Chika Hasegawa
    Takeshi Kumazawa
    Xiao-Pen Lee
    Akemi Marumo
    Natsuko Shinmen
    Hiroshi Seno
    Keizo Sato
    Analytical and Bioanalytical Chemistry, 2007, 389 : 563 - 570
  • [2] Simultaneous determination of methamphetamine and amphetamine in human urine using pipette tip solid-phase extraction and gas chromatography-mass spectrometry
    Kumazawa, Takeshi
    Hasegawa, Chika
    Lee, Xiao-Pen
    Hara, Kenji
    Seno, Hiroshi
    Suzuki, Osamu
    Sato, Keizo
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (02) : 602 - 607
  • [3] Determination of dextromethorphan in human plasma using pipette tip solid-phase extraction and gas chromatography–mass spectrometry
    Chika Hasegawa
    Takeshi Kumazawa
    Seisaku Uchigasaki
    Xiao-Pen Lee
    Keizo Sato
    Masaru Terada
    Kunihiko Kurosaki
    Analytical and Bioanalytical Chemistry, 2011, 401 : 2215 - 2223
  • [4] Pipette tip solid-phase extraction and gas chromatography-mass spectrometry for the determination of mequitazine in human plasma
    Kumazawa, Takeshi
    Hasegawa, Chika
    Lee, Xiao-Pen
    Marumo, Akemi
    Shimmen, Natsuko
    Ishii, Akira
    Seno, Hiroshi
    Sato, Keizo
    TALANTA, 2006, 70 (02) : 474 - 478
  • [5] Determination of dextromethorphan in human plasma using pipette tip solid-phase extraction and gas chromatography-mass spectrometry
    Hasegawa, Chika
    Kumazawa, Takeshi
    Uchigasaki, Seisaku
    Lee, Xiao-Pen
    Sato, Keizo
    Terada, Masaru
    Kurosaki, Kunihiko
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (07) : 2215 - 2223
  • [6] Molecularly imprinted solid-phase extraction for the selective determination of methamphetamine, amphetamine, and methylenedioxyphenylalkylamine designer drugs in human whole blood by gas chromatography-mass spectrometry
    Kumazawa, Takeshi
    Hasegawa, Chika
    Hara, Kenji
    Uchigasaki, Seisaku
    Lee, Xiao-Pen
    Seno, Hiroshi
    Suzuki, Osamu
    Sato, Keizo
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (5-6) : 726 - 733
  • [7] Determination of tricyclic antidepressants in human plasma using pipette tip solid-phase extraction and gas chromatography-mass spectrometry
    Lee, Xiao-Pen
    Hasegawa, Chika
    Kumazawa, Takeshi
    Shinmen, Natsuko
    Shoji, Yukiko
    Seno, Hiroshi
    Sato, Keizo
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (12) : 2265 - 2271
  • [8] Simultaneous determination of ten antihistamine drugs in human plasma using pipette tip solid-phase extraction and gas chromatography/mass spectrometry
    Hasegawa, C
    Kumazawa, T
    Lee, XP
    Fujishiro, M
    Kuriki, A
    Marumo, A
    Seno, H
    Sato, K
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (04) : 537 - 543
  • [9] Determination of amphetamine, methamphetamine and dimethamphetamine in human urine by solid-phase microextraction (SPME) gas chromatography mass spectrometry
    Myung, SW
    Min, HK
    Kim, S
    Kim, M
    Cho, JB
    Kim, TJ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1998, 716 (1-2): : 359 - 365