Mammographically guided fine-needle aspiration cytology of the breast: Reducing the rate of insufficient specimens

被引:12
|
作者
Hayes, MK
DeBruhl, ND
Hirschowitz, S
KimmeSmith, C
Bassett, LW
机构
[1] IRIS CANTOR CTR BREAST IMAGING,DEPT RADIOL SCI,LOS ANGELES,CA 90024
[2] UNIV CALIF LOS ANGELES,SCH MED,DEPT PATHOL,LOS ANGELES,CA 90024
[3] UNIV CALIF LOS ANGELES,SCH MED,JONSSON COMPREHENS CANC CTR,LOS ANGELES,CA 90024
关键词
D O I
10.2214/ajr.167.2.8686610
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to reduce the rate of insufficient specimens from fine-needle aspiration cytology (FNAC) of impalpable mammographically detected breast lesions. SUBJECTS AND METHODS. Our previous rate of insufficient specimens for FNAC was 27%. We implemented the following strategies to reduce this rate and improve accuracy: retraining of radiologists in FNAC procedures, more vigorous sampling, on-site evaluation of specimens by cytopathologist or cytotechnologist, exclusive use of stereotaxic guidance, stereotaxic equipment calibration program, and verification of initial needle placement. RESULTS. Of 77 patients with impalpable abnormalities who underwent FNAC with the new protocol, six (8%) had insufficient specimens for cytologic diagnosis: Four were incorrectly judged to contain sufficient material at the time of FNAC, one refused to complete the FNAC, and one had a vasovagal reaction, Of the six cases with insufficient specimens, four were benign at biopsy, one was malignant, and one was determined to be benign on the basis of mammographic stability. CONCLUSION. Modification of techniques and implementation of a quality assurance program can significantly improve the insufficient specimen rate for FNAC. Correlation of mammographic and cytologic findings also improves the management of these cases.
引用
收藏
页码:381 / 384
页数:4
相关论文
共 50 条
  • [2] Quantity Insufficient Lesions in Ultrasonography-guided Fine-needle Aspiration Cytology of Breast Lesions
    Wong, C. K. K.
    Fung, S. L. A.
    HONG KONG JOURNAL OF RADIOLOGY, 2011, 14 (01): : 10 - 14
  • [3] Fine-needle Aspiration Cytology of the Breast
    Berner, Aasmund
    Sauer, Torill
    ULTRASTRUCTURAL PATHOLOGY, 2011, 35 (04) : 162 - 167
  • [4] PROBLEMS IN FINE-NEEDLE ASPIRATION BIOPSY CYTOLOGY OF CLINICALLY OR MAMMOGRAPHICALLY UNCERTAIN BREAST-TUMORS
    PILOTTI, S
    RILKE, F
    DELPIANO, C
    DIPIETRO, S
    GUZZON, A
    TUMORI, 1982, 68 (05) : 407 - 412
  • [5] ATYPIA IN FINE-NEEDLE ASPIRATION CYTOLOGY OF NONPALPABLE AND PALPABLE MAMMOGRAPHICALLY DETECTED BREAST-LESIONS
    MULFORD, DK
    DAWSON, AE
    ACTA CYTOLOGICA, 1994, 38 (01) : 9 - 17
  • [6] Discomfort with fine-needle aspiration cytology of the breast
    Blennerhassett, M
    LANCET, 2001, 357 (9258): : 805 - 805
  • [7] FINE-NEEDLE ASPIRATION CYTOLOGY IN BREAST LUMPS
    MARCACCIO, MJ
    OBRIEN, SE
    CHEN, VSM
    CANADIAN JOURNAL OF SURGERY, 1986, 29 (06) : 405 - 407
  • [8] THE POTENTIAL VALUE OF MAMMOGRAPHICALLY GUIDED FINE-NEEDLE ASPIRATION BIOPSY OF NONPALPABLE BREAST-LESIONS
    MASOOD, S
    FRYKBERG, ER
    MITCHUM, DG
    MCLELLAN, GL
    SCALAPINO, MC
    BULLARD, JB
    AMERICAN SURGEON, 1989, 55 (04) : 226 - 231
  • [9] FINE-NEEDLE ASPIRATION CYTOLOGY
    GOMPELS, BM
    PIKE, CP
    LANCET, 1979, 2 (8139): : 424 - 424
  • [10] FINE-NEEDLE ASPIRATION CYTOLOGY
    MELCHER, DH
    LINEHAN, JJ
    SMITH, RS
    LANCET, 1979, 2 (8136): : 253 - 253