Implications of high-penetration renewables for ratepayers and utilities in the residential solar photovoltaic (PV) market

被引:54
|
作者
Janko, Samantha A. [1 ]
Arnold, Michael R. [1 ]
Johnson, Nathan G. [1 ]
机构
[1] Arizona State Univ, Polytech Sch, Ira Fulton Sch Engn, 7171 E Sonoran Arroyo Mall,Peralta Hall 330, Mesa, AZ 85212 USA
关键词
Energy economics; Residential solar; Solar photovoltaic (PV); Net metering; Electricity rates; Techno-economic optimization; ENERGY; POWER; WIND; INTEGRATION; SAVINGS; IMPACT; GENERATION; STRATEGIES; MANAGEMENT; SYSTEMS;
D O I
10.1016/j.apenergy.2016.07.041
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Residential energy markets in the United States are undergoing rapid change with increasing amounts of solar photovoltaic (PV) systems installed each year. This study examines the combined effect of electric rate structures and local environmental forcings on optimal solar home system size, ratepayer financials, utility financials, and electric grid ramp rate requirements for three urban regions in the United States. Techno-economic analyses are completed for Chicago, Phoenix, and Seattle and the results contrasted to provide both generalizable findings and site-specific findings. Various net metering scenarios and time-of-use rate schedules are investigated to evaluate the optimal solar PV capacity and battery storage in a typical residential home for each locality. The net residential load profile is created for a single home using BEopt and then scaled to assess technical and economic impacts to the utility for a market segment of 10,000 homes modeled in HOMER. Emphasis is given to intraday load profiles, ramp rate requirements, peak capacity requirements, load factor, revenue loss, and revenue recuperation as a function of the number of ratepayers with solar PV. Increases in solar PV penetration reduced the annual system load factor by an equivalent percentage yet had little to no impact on peak power requirements. Ramp rate requirements were largest for Chicago in October, Phoenix in July, and Seattle in January. Net metering on a monthly or annual basis had a negligible impact on optimal solar PV capacity, yet optimal solar PV capacity reduced by 20-50% if net metering was removed altogether. Technical and economic data are generated from simulations with solar penetration up to 100% of homes. For the scenario with 20% homes using solar PV, the utility would need a 16%, 24%, and 8% increase in time-of-use electricity rates ($/kWh) across all ratepayers to recover lost revenue in Chicago, Phoenix, and Seattle, respectively. The $15 monthly connection fee would need to increase by 94%, 228%, or 50% across the same cities if time-of-use electricity rates were to remain unchanged. Batteries were found to be cost-effective in simulations without net metering and at cost reductions of at least 55%. Batteries were not cost-effective even if they were free-when net metering was in effect. As expected, Phoenix had the most favorable economic scenario for residential solar PV, primarily due to the high solar insolation. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:37 / 51
页数:15
相关论文
共 50 条
  • [1] A Cloud Shadow Model for Analysis of Solar Photovoltaic Power Variability in High-Penetration PV Distribution Networks
    Ebad, Mehdi
    Grady, William Mack
    2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [2] Robust Energy Management for Microgrids With High-Penetration Renewables
    Zhang, Yu
    Gatsis, Nikolaos
    Giannakis, Georgios B.
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2013, 4 (04) : 944 - 953
  • [3] Energy management of cooperative microgrids with high-penetration renewables
    Lahon, Rinalini
    Gupta, Chandra P.
    IET RENEWABLE POWER GENERATION, 2018, 12 (06) : 680 - 690
  • [4] Solar PV high-penetration scenario: an overview of the global PV power status and future growth
    Hossain, M. D. Shouquat
    Al-Fatlawi, A. Wadi
    Kumar, Laveet
    Fang, Yan Ru
    Assad, Mamdouh El Haj
    ENERGY SYSTEMS-OPTIMIZATION MODELING SIMULATION AND ECONOMIC ASPECTS, 2024,
  • [5] Impact of High-Penetration PV on Distribution Feeders
    Tzartzev, Rossen
    Grady, W. Mack
    Patel, Jay
    2012 3RD IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT EUROPE), 2012,
  • [6] Optimal energy management for industrial microgrids with high-penetration renewables
    Han Li
    Abinet Tesfaye Eseye
    Jianhua Zhang
    Dehua Zheng
    Protection and Control of Modern Power Systems, 2017, 2 (1)
  • [7] Potential Effect and Analysis of High Residential Solar Photovoltaic (PV) Systems Penetration to an Electric Distribution Utility (DU)
    Dellosa, Jeffrey T.
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY DEVELOPMENT-IJRED, 2016, 5 (03): : 179 - 185
  • [8] Impact of High-Penetration Photovoltaic on Synchronous Generator Stability
    Yagami, M.
    Tamura, J.
    2012 XXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2012, : 2092 - 2097
  • [9] Prevention of output suppression through heat pump water heaters for high-penetration residential PV systems
    Miyamoto, Yusuke
    Hayashi, Yasuhiro
    2013 IEEE 39TH PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2013, : 1715 - 1720
  • [10] Distribution System Voltage Performance Analysis for High-Penetration PV
    Liu, Y.
    Bebic, J.
    Kroposki, B.
    de Bedout, J.
    Ren, W.