Tumor visualization and fluorescence angiography with indocyanine green (ICG) in laparoscopic and robotic hepatobiliary surgery - valuation of early adopters from Germany

被引:31
|
作者
Franz, Mareike [1 ]
Arend, Joerg [1 ]
Wolff, Stefanie [1 ]
Perrakis, Aristotelis [1 ]
Rahimli, Mirhasan [1 ]
Negrini, Victor-Radu [1 ]
Stockheim, Jessica [1 ]
Lorenz, Eric [1 ]
Croner, Roland [1 ]
机构
[1] Univ Hosp Magdeburg, Dept Gen Visceral Vasc & Transplant Surg, Leipziger Str 44, D-39120 Magdeburg, Germany
来源
INNOVATIVE SURGICAL SCIENCES | 2021年 / 6卷 / 02期
关键词
CCC; CRLM indocyanine green; HCC; ICG; laparoscopic surgery; robotic surgery; NAVIGATION SYSTEM; LIVER; CHOLANGIOGRAPHY; CHOLECYSTECTOMY; RESECTION; MANAGEMENT;
D O I
10.1515/iss-2020-0019
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: Indocyanine green (ICG) is a fluorescent dye which was initially used for liver functional assessment. Moreover, it is of value for intraoperative visualization of liver segments and bile ducts or primary and secondary liver tumors. Especially in minimally invasive liver surgery, this is essential to enhance the precision of anatomical guided surgery and oncological quality. As early adopters of ICG implementation into laparoscopic and roboticassisted liver surgery in Germany, we summarize the current recommendations and share our experiences. Methods: Actual strategies for ICG application in minimally invasive liver surgery were evaluated and summarized during a review of the literature. Experiences in patients who underwent laparoscopic or robotic-assisted liver surgery with intraoperative ICG staining between 2018 and 2020 from the Magdeburg registry for minimally invasive liver surgery (MD-MILS) were evaluated and the data were analyzed retrospectively. Results: ICG can be used to identify anatomical liver segments by fluorescence angiography via direct or indirect tissue staining. Fluorescence cholangiography visualizes the intra- and extrahepatic bile ducts. Primary and secondary liver tumors can be identified with a sensitivity of 69-100%. For this 0.5 mg/kg body weight ICG must be applicated intravenously 2-14 days prior to surgery. Within the MD-MILS we identified 18 patients which received ICG for intraoperative tumor staining of hepatocellular carcinoma (HCC), cholangiocarcinoma, peritoneal HCC metastases, adenoma, or colorectal liver metastases. The sensitivity for tumor staining was 100%. In 27.8% additional liver tumors were identified by ICG fluorescence. In 39% a false positive signal could be detected. This occurred mainly in cirrhotic livers. Conclusions: ICG staining is a simple and useful tool to assess individual hepatic anatomy or to detect tumors during minimally invasive liver surgery. It may enhance surgical precision and improve oncological quality. False-positive detection rates of liver tumors can be reduced by respecting the tumor entity and liver functional impairments.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 50 条
  • [1] Indocyanine green (ICG) fluorescence in robotic hepatobiliary surgery: A systematic review
    Potharazu, Archit V.
    Gangemi, Antonio
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2023, 19 (01):
  • [2] Indocyanine green (ICG) fluorescence technology in pediatric robotic surgery
    Esposito, Ciro
    Masieri, Lorenzo
    Cerulo, Mariapina
    Castagnetti, Marco
    Del Conte, Fulvia
    Di Mento, Claudia
    Esposito, Giorgia
    Tedesco, Francesco
    Carulli, Roberto
    Continisio, Leonardo
    Chiodi, Annalisa
    Escolino, Maria
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)
  • [3] Image-Guided Pediatric Surgery Using Indocyanine Green (ICG) Fluorescence in Laparoscopic and Robotic Surgery
    Esposito, Ciro
    Settimi, Alessandro
    Del Conte, Fulvia
    Cerulo, Mariapina
    Coppola, Vincenzo
    Farina, Alessandra
    Crocetto, Felice
    Ricciardi, Elisabetta
    Esposito, Giovanni
    Escolino, Maria
    FRONTIERS IN PEDIATRICS, 2020, 8
  • [4] Intraoperative fluorescence angiography and cholangiography with indocyanine green in hepatobiliary surgery
    Oldhafer, Karl J.
    Reese, Tim
    Fard-Aghaie, Mohammad
    Strohmaier, Alina
    Makridis, Georgios
    Kantas, Alexandros
    Wagner, Kim C.
    CHIRURG, 2019, 90 (11): : 880 - 886
  • [5] THE USAGE OF INDOCYANINE GREEN (ICG) FLUORESCENCE ANGIOGRAPHY TO ASSESS ANASTOMOTIC PERFUSION IN ROBOTIC COLORECTAL SURGERY.
    Liu, W.
    Blitzer, D.
    Ferris, J.
    Lisle, D.
    DISEASES OF THE COLON & RECTUM, 2021, 64 (05)
  • [6] Indocyanine green fluorescence angiography during laparoscopic and robotic colorectal surgery - a video vignette
    Hamilton, A. E. Ricardo
    Cuda, T. J.
    Westwood, D. A.
    Stevenson, A. R. L.
    COLORECTAL DISEASE, 2018, 20 (03) : 255 - 257
  • [7] Clinical applications of indocyanine green (ICG) enhanced fluorescence in laparoscopic surgery
    Luigi Boni
    Giulia David
    Alberto Mangano
    Gianlorenzo Dionigi
    Stefano Rausei
    Sebastiano Spampatti
    Elisa Cassinotti
    Abe Fingerhut
    Surgical Endoscopy, 2015, 29 : 2046 - 2055
  • [8] Clinical applications of indocyanine green (ICG) enhanced fluorescence in laparoscopic surgery
    Boni, Luigi
    David, Giulia
    Mangano, Alberto
    Dionigi, Gianlorenzo
    Rausei, Stefano
    Spampatti, Sebastiano
    Cassinotti, Elisa
    Fingerhut, Abe
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2015, 29 (07): : 2046 - 2055
  • [9] A bibliometric analysis of indocyanine green (ICG) in hepatobiliary surgery from 2008 to 2021
    Li, Donglun
    Hu, Yue
    Kang, Maoji
    Fang, Cheng
    Gan, Yu
    Yang, Xiaoli
    Peng, Fangyi
    Li, Bo
    Wu, Jiali
    Su, Song
    HELIYON, 2024, 10 (12)