Precise coulometric determination of redox inert anions based on electrolysis at the aqueous|organic solution interface

被引:7
|
作者
Kasuno, Megumi [1 ,2 ]
Fujimoto, Kazuma [1 ]
Kakitani, Yuri [1 ]
Matsushita, Takayuki [1 ]
Kihara, Sorin [3 ]
机构
[1] Ryukoku Univ, Fac Sci & Technol, Dept Chem Mat, Shiga 5202194, Japan
[2] Ryukoku Univ, Innovat Mat & Proc Res Ctr, Dept Chem Mat, Shiga 5202194, Japan
[3] Kyoto Inst Interesting Chem, Yamashina Ku, Kyoto 6078466, Japan
关键词
Redox inert anion; Coulometry; Ion transfer at the aqueous vertical bar organic solution interface; Rapid flow electrolysis; Flow injection method; ION TRANSFER; EXTRACTION;
D O I
10.1016/j.jelechem.2010.11.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The flow cell proposed previously for the rapid and coulometric determination of cations based on the electrochemical ion transfer at the aqueous vertical bar organic solution interface was improved to be applicable to the determination of anions. The developed cell was composed of a porous poly(tetrafluoroethylene) tube (1.0 mm in inner diameter), a copper wire (0.8 mm in diameter) inserted into the tube, a platinum wire placed outside the tube, an organic solution into which the tube was immersed and a reference electrode in the organic solution. The aqueous solution containing a species of interest was flowed through the narrow gap between the tube and the copper wire. A potential difference was applied at the agueous vertical bar organic solution interface by using the copper wire and the reference electrode in the organic solution in order to realize the ion transfer at the interface, and the current due to the interfacial ion transfer was detected by the copper and platinum wires. The developed cell was evaluated adopting the transfer of an anion such as perchlorate, picrate or alkylsulphonates from the aqueous solution to 1,2-dichloroethane (used as the organic solution), and demonstrated that the anions of 10(-4) mol dm(-3) level could be determined with coefficients of variations better than 0.2% (n = 5). The applicability of the developed cell to the flow injection analysis of anions was also discussed. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:111 / 117
页数:7
相关论文
共 50 条
  • [1] Rapid and Precise Coulometric Determination and Separation of Redox Inert Ions Based on Electrolysis for Ion Transfer at the Aqueous|Organic Solution Interface
    Sorin Kihara
    Megumi Kasuno
    Analytical Sciences, 2011, 27 : 1 - 11
  • [2] Rapid and Precise Coulometric Determination and Separation of Redox Inert Ions Based on Electrolysis for Ion Transfer at the Aqueous|Organic Solution Interface
    Kihara, Sorin
    Kasuno, Megumi
    ANALYTICAL SCIENCES, 2011, 27 (01) : 1 - 11
  • [3] Rapid and Precise Coulometric Determination of Calcium Based on Electrolysis for Ion Transfer at the Aqueous | Organic Solution Interface
    Kasuno, Megumi
    Kakitani, Yuri
    Shibafuji, Yayoi
    Okugaki, Tomohiko
    Maeda, Kohji
    Matsushita, Takayuki
    Kihara, Sorin
    ELECTROANALYSIS, 2009, 21 (17-18) : 2022 - 2029
  • [4] Rapid and coulometric electrolysis for ion transfer at the aqueouslorganic solution interface
    Yoshizumi, A
    Uehara, A
    Kasuno, M
    Kitatsuji, Y
    Yoshida, Z
    Kihara, S
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 581 (02) : 275 - 283
  • [5] THE TRANSFER OF CARBOXYLATE AND SULFONATE ANIONS AT THE AQUEOUS ORGANIC SOLUTION INTERFACE STUDIED BY POLAROGRAPHY WITH THE ELECTROLYTE SOLUTION DROPPING ELECTRODE
    KIHARA, S
    SUZUKI, M
    SUGIYAMA, M
    MATSUI, M
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 249 (1-2): : 109 - 122
  • [6] COADSORPTION OF ORGANIC CATIONS AND DIFFERENT ANIONS AT THE SOLUTION MERCURY AND SOLUTION AIR INTERFACE
    DAMASKIN, BB
    GEROVICH, VM
    PODGORNAYA, MI
    SOVIET ELECTROCHEMISTRY, 1986, 22 (01): : 98 - 103
  • [7] Large variations in the propensity of aqueous oxychlorine anions for the solution/vapor interface
    Ottosson, Niklas
    Vacha, Robert
    Aziz, Emad F.
    Pokapanich, Wandared
    Eberhardt, Wolfgang
    Svensson, Svante
    Ohrwall, Gunnar
    Jungwirth, Pavel
    Bjorneholm, Olle
    Winter, Bernd
    JOURNAL OF CHEMICAL PHYSICS, 2009, 131 (12):
  • [8] Determination of organic and inorganic anions in aqueous media by ion chromatography
    Safonova E.F.
    Selemenev V.F.
    Brezhneva T.A.
    Slivkin A.I.
    Pharmaceutical Chemistry Journal, 1999, 33 (11) : 622 - 623
  • [9] Quantitative determination of metal ions and anions in aqueous solution by using pH-responsive redox-active receptors
    PadillaTosta, ME
    MartinezManez, R
    Pardo, T
    Soto, J
    Tendero, MJL
    CHEMICAL COMMUNICATIONS, 1997, (09) : 887 - 888
  • [10] RAPID MICROMETHODS OF ELEMENTAL ANALYSIS .3. PRECISE COULOMETRIC DETERMINATION OF HYDROGEN IN ORGANIC COMPOUNDS
    OLSON, EC
    STRUCK, WA
    HOUTMAN, RL