Blood pool contrast-enhanced MRA: Improved arterial visualization in the steady state

被引:17
|
作者
van Bemmel, CM
Wink, O
Verdonck, B
Viergever, MA
Niessen, WJ
机构
[1] Univ Utrecht, Ctr Med, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
[2] Philips Med Syst, NL-5680 DA Best, Netherlands
关键词
blood pool agent; contrast-enhanced MRA; visualization;
D O I
10.1109/TMI.2003.812262
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Blood pool agents (BPAs) for contrast-enhanced magnetic resonance angiography (CE-MRA) allow prolonged imaging during the steady state when the agent is distributed through the complete vascular system. This increases both the spatial resolution and the contrast resolution. However, simultaneous venous; and arterial enhancement hampers interpretation. For the pelvic region of the vasculature, it is shown that arterial visualization in this equilibrium phase can be improved if the central arterial axis (CAA) is known. However, manually obtaining this axis is not feasible in clinical practice. Therefore, a method is presented that utilizes images acquired during the first pass of the contrast agent to find the CAA in the steady-state data with minimum user initialization. The accuracy of the resulting CAA is compared with tracings of three observers in six patient datasets. It was found that the mean difference between the semiautomatic method and the manual delineation is 1.32 mm in the steady-state data, and that the resulting CAA was always within the arterial lumen, which is an important prerequisite for both improved visualization and segmentation.
引用
收藏
页码:645 / 652
页数:8
相关论文
共 50 条
  • [1] Improved arterial visualization in blood pool agent MRA of the peripheral vasculature
    Niessen, WJ
    van Swijndregt, ADM
    Elsman, BHP
    Wink, O
    Viergever, MA
    Mali, WPTM
    CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 119 - 123
  • [3] Visualization techniques for blood pool contrast-enhanced magnetic resonance angiography
    Yucel, EK
    ACADEMIC RADIOLOGY, 2002, 9 : S140 - S142
  • [4] Contrast-enhanced propeller MRA
    Pipe, J.
    Acta Radiologica Supplementum, 2000, 41 (Suppl 422)
  • [5] Contrast-enhanced coronary MRA
    Lorenz, CH
    Johansson, LOM
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (05) : 703 - 708
  • [6] CONTRAST-ENHANCED MRA OF THE BRAIN
    MARCHAL, G
    MICHIELS, J
    BOSMANS, H
    VANHECKE, P
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (01) : 25 - 29
  • [7] Contrast-enhanced renal MRA
    Meaney, J.F.M.
    Acta Radiologica Supplementum, 2000, 41 (Suppl 422)
  • [8] Enhanced artery visualization in blood pool MRA: Results in the peripheral vasculature
    Niessen, W
    van Swijndregt, AM
    Elsman, B
    Wink, O
    Viergever, M
    Mali, W
    INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 1999, 1613 : 340 - 345
  • [9] Blood pool agent contrast-enhanced MRA: Level-set based artery-vein separation
    van Bemmela, CM
    Spreeuwers, L
    Verdonck, B
    Viergever, MA
    Niessen, WJ
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 1464 - 1475
  • [10] Contrast-enhanced MRA of intracranial vessels
    Anzalone, N
    EUROPEAN RADIOLOGY, 2005, 15 : E3 - E10