Electrooxidation and determination of perphenazine on a graphene oxide nanosheet-modified electrode

被引:18
|
作者
Heli, H. [1 ,2 ]
Sattarahmady, N. [1 ,2 ,3 ]
Zare, S. N. [1 ]
机构
[1] Shiraz Univ Med Sci, Nanomed & Nanobiol Res Ctr, Shiraz, Iran
[2] Shiraz Univ Med Sci, Sch Adv Med Sci & Technol, Dept Nanomed, Shiraz, Iran
[3] Shiraz Univ Med Sci, Sch Med, Dept Med Phys, Shiraz, Iran
基金
美国国家科学基金会;
关键词
SPECTROPHOTOMETRIC DETERMINATION; ELECTROCATALYTIC OXIDATION; QUANTITATIVE-DETERMINATION; PHENOTHIAZINE-DERIVATIVES; ELECTROCHEMICAL DETECTION; CHEMILUMINESCENCE METHOD; SENSITIVE DETECTION; ASCORBIC-ACID; SENSOR; NANOCOMPOSITE;
D O I
10.1039/c5ra01405k
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The electrochemical behavior of perphenazine was investigated on a graphene oxide nanosheet-modified glassy carbon electrode in a phosphate buffer solution at pH 7.4. Cyclic voltammetry was employed to study the drug electrooxidation process. Perphenazine was electrooxidized on the modified electrode surface at lower potentials with a higher rate through an irreversible process. The kinetic parameters of the electrooxidation reaction, including the standard rate constant as well as diffusion and charge transfer coefficients were obtained. Amperometric and differential pulse voltammetric procedures were developed for the determination of perphenazine. Linear dynamic ranges of 0.8-8.0 and 0.7-7.0 mmol L-1 with calibration sensitivities of 35.23 and 36.54 mA mol(-1) L cm(-2) and detection limits of 46.6 and 38.4 mu mol L-1 were obtained using amperometry and differential pulse voltammetry, respectively. The amperometric method was applied in the analysis of perphenazine tablets, and the applicability of the method for the direct assays of spiked human serum, urine and breast milk fluids was investigated.
引用
收藏
页码:21005 / 21011
页数:7
相关论文
共 50 条
  • [1] Direct Electrodeposition to Fabricate a Graphene Nanosheet-Modified Electrode for Imidacloprid Determination
    Yan, Liang
    Li, Zhicheng
    Zhang, Shaojun
    NANO, 2016, 11 (07)
  • [2] A graphene oxide nanosheet-modified Ti nanocomposite electrode with enhanced electrochemical property and stability for nitrate reduction
    Ma, Xuejiao
    Li, Miao
    Liu, Xiang
    Wang, Lele
    Chen, Nan
    Li, Jiacheng
    Feng, Chuanping
    CHEMICAL ENGINEERING JOURNAL, 2018, 348 : 171 - 179
  • [3] Electrooxidation and determination of flufenamic acid at graphene oxide modified carbon electrode
    Shetti, Nagaraj P.
    Nayak, Deepti S.
    Malode, Shweta J.
    Kulkarni, Raviraj M.
    Kulkarni, Dipak B.
    Teggi, Rupa A.
    Joshi, Varun V.
    SURFACES AND INTERFACES, 2017, 9 : 107 - 113
  • [4] Synthesis and characterization of graphene nanosheet-modified polycrystalline diamond compact
    Yang, Xuefeng
    Li, Zhengxin
    Deng, Fuming
    INTERNATIONAL JOURNAL OF REFRACTORY METALS & HARD MATERIALS, 2021, 101
  • [5] In Situ One-Step Electrochemical Preparation of Graphene Oxide Nanosheet-Modified Electrodes for Biosensors
    Zeng, Fanwu
    Sun, Zhenhua
    Sang, Xiaoguang
    Diamond, Dermot
    Lau, King Tong
    Liu, Xiaoxia
    Su, Dang Sheng
    CHEMSUSCHEM, 2011, 4 (11) : 1587 - 1591
  • [6] Electrooxidation Behavior and Amperometric Determination of Sotalol on a Graphene Oxide Nanosheets-modified Glassy Carbon Electrode
    Heli, Hossein
    Zare, Seyede Nasrin
    Sattarahmady, Naghmeh
    Karimian, Khashayar
    CURRENT PHARMACEUTICAL ANALYSIS, 2013, 9 (03) : 291 - 298
  • [7] Electrochemical evaluation of magnetic reduced graphene oxide nanosheet-modified glassy carbon electrode on dopamine electrochemical sensor for Parkinson's diagnostic application
    Hardiansyah, Andri
    Saputra, Gardin Muhammad Andika
    Hikmat, Hikmat
    Kusfarida, Yuniar Elfira
    Septiani, Ni Luh Wulan
    Randy, Ahmad
    Hermawan, Angga
    Yuliarto, Brian
    Liu, Ting-Yu
    Kida, Tetsuya
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2023, 70 (08) : 1665 - 1682
  • [8] Electrochemical behavior of horseradish peroxidase on WS2 nanosheet-modified electrode and electrocatalytic investigation
    Niu, Yanyan
    Zou, Ruyi
    Yones, Hamza Abdalla
    Li, Xiaobao
    Li, Xiaoyan
    Niu, Xueliang
    Chen, Yong
    Li, Pan
    Sun, Wei
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2018, 65 (09) : 1127 - 1135
  • [9] A selective and sensitive electrochemical determination of catechol based on reduced graphene oxide decorated β-cyclodextrin nanosheet modified glassy carbon electrode
    Nikhil, S.
    Karthika, A.
    Suresh, P.
    Suganthi, A.
    Rajarajan, M.
    ADVANCED POWDER TECHNOLOGY, 2021, 32 (07) : 2148 - 2159
  • [10] Electrochemical Determination of Dexrazoxane by Differential Pulse Voltammetry (DPV) Using a Graphene Oxide Nanosheet Modified Pencil Graphite Electrode (PGE)
    Akpmar, Fatma
    Sensoy, Kubra Gencdag
    Muti, Mihrican
    ANALYTICAL LETTERS, 2023, 56 (04) : 630 - 642