In manual-visual differential leukocyte counts, the counting itself may be different depending on the examiner. We estimated the between-examiner (B-E) reproducibility in differential leukocyte counting. During 2 months, daily, after performing manual-visual differential leukocyte counts, two slides with blood films were retained. Next day these two blood films were re-examined by different examiners. For each type of leukocyte the B-E reproducibility was estimated from the 58 pairs of data obtained by four technicians. The B-E coefficient of variation for each type of leukocyte was: basophilocytes, 263.2%; eosinophilocytes, 68.8%; lymphocytes, 32.5%; metamyelocytes, 69.6%; monocytes, 55.0%; myelocytes, 132.5%; and neutrophilocytes, 6.6%. For each type of leukocyte the coefficient of variation is the sought estimate of the average reproducibility due to the "human factor" as a whole, without regard to any examiner in particular. Knowledge of this component of day-to-day imprecision, and its follow-up, may be used to decide corrective actions (training of the examiner, etc.) and to set critical differences to interpret the significance of changes in serial results.
引用
收藏
页码:643 / 645
页数:3
相关论文
共 50 条
  • [1] Between-examiner reproducibility in manual differential leukocyte counting
    Xavier Fuentes-Arderiu
    Mariona García-Panyella
    Dolors Dot-Bach
    Accreditation and Quality Assurance, 2007, 12 : 643 - 645
  • [2] Measurement uncertainty in manual differential leukocyte counting
    Fuentes-Arderiu, Xavier
    Dot-Bach, Dolors
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2009, 47 (01) : 112 - 115
  • [3] A CRITICAL-EVALUATION OF THE MANUAL VISUAL DIFFERENTIAL LEUKOCYTE COUNTING METHOD
    KOEPKE, JA
    DOTSON, MA
    SHIFMAN, MA
    BLOOD CELLS, 1985, 11 (02): : 173 - 186
  • [4] Within- and between-examiner repeatability of distraction indices of the hip joints in dogs
    Smith, GK
    LaFond, E
    Gregor, TP
    Lawler, DF
    Nie, RC
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1997, 58 (10) : 1076 - 1077
  • [5] Intra- and inter-examiner reproducibility of manual probing depth
    Andrade, Roberto
    Espinoza, Manuel
    Maria Gomez, Elena
    Rolando Espinoza, Jose
    Cruz, Elizabeth
    BRAZILIAN ORAL RESEARCH, 2012, 26 (01) : 57 - 63
  • [6] EVALUATION OF AN AUTOMATED DIFFERENTIAL LEUKOCYTE COUNTING SYSTEM .1. INSTRUMENT DESCRIPTION AND REPRODUCIBILITY STUDIES
    DUTCHER, TF
    BENZEL, JE
    EGAN, JJ
    HART, DJ
    CHRISTOPHER, EA
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1974, 62 (04) : 525 - 529
  • [7] Within- and between-examiner agreement for two thyroid palpation techniques in healthy and hyperthyroid cats
    Paepe, Dominique
    Smets, Pascale
    van Hoek, Ingrid
    Saunders, Jimmy
    Duchateau, Luc
    Daminet, Sylvie
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2008, 10 (06) : 558 - 565
  • [8] AUTOMATIC MICROSCOPE SYSTEM FOR DIFFERENTIAL LEUKOCYTE COUNTING
    DEW, B
    KING, T
    MIGHDOLL, D
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1974, 22 (07) : 685 - 696
  • [9] SOURCES OF PHYSIOLOGICAL VARIATION IN DIFFERENTIAL LEUKOCYTE COUNTING
    SAUNDERS, AM
    BLOOD CELLS, 1985, 11 (01): : 31 - 48
  • [10] Microfluidic differential immunocapture biochip for specific leukocyte counting
    Umer Hassan
    Nicholas N Watkins
    Bobby Reddy
    Gregory Damhorst
    Rashid Bashir
    Nature Protocols, 2016, 11 : 714 - 726