A Histogram-Difference Method for Neutron/Gamma Discrimination Using Liquid and Plastic Scintillators

被引:9
|
作者
French, Robert M. [1 ]
Thevenin, Mathieu [2 ]
Hamel, Matthieu [2 ]
Montbarbon, Eva [2 ]
机构
[1] Univ Bourgogne, French Natl Ctr Sci Res, F-21000 Dijon, France
[2] CEA, LIST, French Atom Energy Commiss, F-91191 Gif Sur Yvette, France
关键词
Neutron-gamma discrimination; plastic scintillators; Qtail; Qtotal; PULSE-SHAPE DISCRIMINATION; GAMMA DISCRIMINATION; PERFORMANCE; DETECTORS; CF-252;
D O I
10.1109/TNS.2017.2720798
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper introduces a novel and extremely simple-and therefore, easily implemented in a fieldprogrammable gate array-method of neutron/gamma pulse discrimination called the histogram-difference method (HDM). Crucially, this method relies on the use of a "reference set" of gamma-only pulses from Na-22, Cs-137, and Co-60 sources and on features extracted from the pulses. The pulses from this reference set are compared to a set of an identical number of n+gamma pulses from a Cf-252 source. Not only can HDM determine the presence of neutrons in the 252Cf source, but it can also estimate the approximate percentage of neutron pulses from that source. The results reported in this paper are based on data from different radioactive sources and a standard scintillator for this type of research, namely, BC-501A. These results were confirmed using three other scintillators, one made in-house and two others that are commercially available, EJ-299-33 and EJ-200. Pulses were encoded using Q values, which are features extracted from the pulses, that is, (Q(total), Q(tail)) pairs in SR2. As control, we also encoded pulses as the root-mean-square (RMS) distances from the average pulse of all known. -only pulses and ran HDM using these pulse representations. The results are very similar to those obtained using a Q-value encoding of the pulses.
引用
收藏
页码:2423 / 2432
页数:10
相关论文
共 50 条
  • [1] Neutron-gamma discrimination in plastic scintillators
    Hansen, RR
    Reeder, PL
    Peurrung, AJ
    Stromswold, DC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (06) : 2024 - 2028
  • [2] Plastic Scintillators With Neutron/Gamma Pulse Shape Discrimination
    van Loef, Edgar V.
    Markosyan, Gary
    Shirwadkar, Urmila
    Shah, Kanai S.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (01) : 467 - 471
  • [3] Plastic scintillators with efficient neutron/gamma pulse shape discrimination
    Zaitseva, Natalia
    Rupert, Benjamin L.
    Pawelczak, Iwona
    Glenn, Andrew
    Martinez, H. Paul
    Carman, Leslie
    Faust, Michelle
    Cherepy, Nerine
    Payne, Stephen
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 668 : 88 - 93
  • [4] A Novel Wavelet-Based Method for Neutron/Gamma Discrimination in Liquid Scintillators
    Yousefi, S.
    Lucchese, L.
    Aspinall, M. D.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1662 - +
  • [5] Neutron and gamma discrimination by compensation of long components in liquid scintillators
    Ianakiev, K. D.
    Alexandrov, B.
    Moss, C. E.
    Nguyen, H.
    Williams, R. B.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2522 - 2525
  • [6] A linear separation method for neutron/gamma discrimination with organic scintillators
    Zhou, Hongzhao
    Xiao, Wuyun
    Liu, Haixia
    Sun, Tao
    Li, Chongwei
    Liu, Lufeng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1048
  • [7] Triplet Harvesting Plastic Scintillators with Neutron-Gamma Pulse Shape Discrimination
    van Loef, Edgar V.
    Feng, Patrick
    Markosyan, Gary
    Shirwadkar, Urmila
    Doty, Patrick
    Shah, Kanai S.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XVI, 2014, 9213
  • [8] Discrimination methods between neutron and gamma rays for boron loaded plastic scintillators
    Normand, S
    Mouanda, B
    Haan, S
    Louvel, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 484 (1-3): : 342 - 350
  • [9] Multilayer phoswich scintillators for neutron / gamma discrimination
    Coulon, Romain
    Kondrasovs, Vladimir
    Lecomte, Quentin
    Dumazert, Jonathan
    RADIATION MEASUREMENTS, 2018, 117 : 57 - 62
  • [10] Neutron/gamma pulse shape discrimination (PSD) in plastic scintillators with digital PSD electronics
    Hutcheson, Anthony L.
    Simonson, Duane L.
    Christophersen, Marc
    Phlips, Bernard F.
    Charipar, Nicholas A.
    Pique, Alberto