Sustainable Shear Behaviour of 2-Span Continuous Reinforced Concrete T-Beams with CFRP Strips

被引:2
|
作者
Samad, Abdul Aziz Abdul [1 ]
Alferjani, Marwan B. S. [2 ]
Ali, Noorwirdawati [1 ]
Mohamad, Noridah [2 ]
Ahmad, Mohd Hilton [1 ]
Tee, Kong Fah [3 ]
Mendis, Priyan [4 ]
机构
[1] Univ Tun Hussein Onn Malaysia, Jamilus Res Ctr, Parit Raja 86400, Johor, Malaysia
[2] Univ Tun Hussein Onn Malaysia, Fac Civil & Environm Engn, Parit Raja 86400, Johor, Malaysia
[3] Univ Greenwich, Dept Engn Sci, Chatham ME4 4TB, Kent, England
[4] Univ Melbourne, Dept Infrastruct Engn, Parkville, Vic 3010, Australia
关键词
CAPACITY;
D O I
10.1051/matecconf/201710302014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Reinforced concrete (RC) structures are generally subjected to various load conditions and are susceptible to environmental impact. With time, most of these structures will be subjected to change in their usage. Unexpected increase in load changes may cause severe damage to the structural components, and eventual leading to various types of structural failure. It is noted that shear failure in nature is a sudden failure and should be avoided at all times. To increase its service life due to shear, structures can be strengthened or repaired using CFRP strips wrapped within the shear span (a(v)) of the beam. Hence, this paper presents an investigation on the sustainable behaviour of two span continuous RC T-beams strengthened and repaired by wrapping Carbon Fibre Reinforced Polymer (CFRP) strips at intervals along the shear span (a(v)) of the beam. The CFRP strips will be orientated in two directions either at 0 degrees/90 degrees or 45 degrees/35 degrees. Five beams, one control beam, two initially strengthened beams and two precracked and repaired beams were cast and cured in room temperature before testing. All T-beams were designed to fail in shear and are subjected to four-point bending test until failure. Upon completion of the test, all beam specimens shows good sustainable behaviour as the ultimate load and shear load shows an increase in capacity by up to 23% with improve ductile behaviour.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Shear Strengthening and Shear Repair of 2-Span Continuous RC Beams with CFRP Strips
    Samad, Abdul Aziz Abdul
    Ali, Noorwirdawati
    Mohamad, Noridah
    Jayaprakash, J.
    Tee, Kong Fah
    Mendis, Priyan
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2017, 21 (03)
  • [2] FINITE ELEMENT MODELLING OF 2-SPAN CONTINUOUS RC BEAMS SHEAR STRENGTHENED AND SHEAR REPAIRED WITH CFRP STRIPS
    Samad, Abdul Aziz Abdul
    Ali, Noorwirdawati
    Mohamad, Noridah
    Jayaprakash, J.
    Tuan Duc Ngo
    Mendis, Priyan
    JURNAL TEKNOLOGI, 2016, 78 (05): : 457 - 462
  • [3] Torsional behavior of reinforced concrete T-beams strengthened with CFRP strips
    Atea, Rafid Saeed
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2017, 7 : 110 - 117
  • [4] BEHAVIOUR OF REINFORCED CONCRETE T-BEAMS IN SHEAR.
    Kotsovos, M.D.
    Bobrowski, J.
    Eibl, J.
    Structural Engineer, Part B: R&D Quarterly, 1987, 65 B (01): : 1 - 10
  • [5] Shear behavior of full-scale reinforced concrete T-beams strengthened with CFRP strips and anchors
    Kim, Yungon
    Ghannoum, Wassim M.
    Jirsa, James O.
    CONSTRUCTION AND BUILDING MATERIALS, 2015, 94 : 1 - 9
  • [6] Shear Strengthening of Reinforced Concrete T-Beams with Anchored CFRP Laminates
    Mhanna, Haya H.
    Hawileh, Rami A.
    Abdalla, Jamal A.
    Salama, Ahmad S. D.
    Alkhrdaji, Tarek
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2021, 25 (04)
  • [7] CFRP Shear Strengthening of Reinforced-Concrete T-Beams with Corroded Shear Links
    Qin, Shunde
    Dirar, Samir
    Yang, Jian
    Chan, Andrew H. C.
    Elshafie, Mohammed
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2015, 19 (05)
  • [8] Efficient CFRP Strap Configurations for the Shear Strengthening of Reinforced Concrete T-Beams
    Hoult, Neil A.
    Lees, Janet M.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2009, 13 (01) : 45 - 52
  • [9] Shear strength of reinforced concrete T-beams
    Zararis, Ioannis P.
    Karaveziroglou, Maria K.
    Zararis, Prodromos D.
    ACI STRUCTURAL JOURNAL, 2006, 103 (05) : 693 - 700
  • [10] Shear strength of reinforced concrete T-beams
    Aristotle University of Thessaloniki, Thessaloniki, Greece
    不详
    ACI Struct J, 2006, 5 (693-700):