Turbulence and Magnetic Field Calculations in High-Voltage Circuit Breakers

被引:21
|
作者
Gonzalez, Jean-Jacques [1 ]
Freton, Pierre [1 ]
Reichert, Frank [2 ]
Randrianarivao, Dannet [1 ]
机构
[1] Univ Toulouse 3, Lab Plasma & Energy Convers LAPLACE, CNRS, INPT,UMR 5213, F-31062 Toulouse, France
[2] Siemens AG, ET HP CB PLM R&D B PB, D-13629 Berlin, Germany
关键词
High-voltage circuit breaker (HVCB); magnetic field; thermal plasma; transient study; turbulent; TEFLON ABLATION; MODEL; ARCS;
D O I
10.1109/TPS.2011.2180404
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
In high-voltage circuit breakers (HVCBs), the representation of convection is essential to provide a satisfactory description of the pressure increase in the heating volume or thermal expansion chamber. The plasma flow is mainly governed by Lorentz forces and turbulence effects. The Lorentz forces depend on the self-induced magnetic field which can be calculated by several approaches. A mixing formulation based on resolving the potential vectors and a Biot-Savart integral for the boundary condition is applied. The difference between this formulation and a null flux boundary condition is illustrated. The mixing formulation gives similar results to the use of Biot-Savart over the entire domain but is much less time consuming. To represent turbulence, one of the most frequently used models is the Prandtl mixing length model (PMLM). Nevertheless, recent works have demonstrated that the realizable model (RM) must represent the flow behavior in the heating volume. Such a model was applied and compared to the PMLM over the entire HVCB domain. The RM is clearly suitable to describe the turbulence in HVCB geometry.
引用
收藏
页码:936 / 945
页数:10
相关论文
共 50 条
  • [1] HIGH-VOLTAGE VACUUM CIRCUIT BREAKERS
    SHORES, RB
    PHILLIPS, VE
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, 94 (05): : 1821 - 1830
  • [2] RELIABILITY OF HIGH-VOLTAGE CIRCUIT-BREAKERS
    KOPPL, G
    ERNI, H
    BROWN BOVERI REVIEW, 1973, 60 (04): : 128 - 133
  • [3] Digital testing of high-voltage circuit breakers
    Schavemaker, PH
    van der Sluis, L
    Smeets, RPP
    Kertész, V
    IEEE COMPUTER APPLICATIONS IN POWER, 2000, 13 (02): : 52 - 56
  • [4] RELIABILITY OF HIGH-VOLTAGE CIRCUIT-BREAKERS
    HOFFMANN, D
    ELEKTROTECHNISCHE ZEITSCHRIFT-ETZ, 1979, 100 (16-1): : 896 - 900
  • [5] Accelerated diagnostics of high-voltage circuit breakers
    Mikheev G.M.
    Fedorov Yu.A.
    Shevtsov V.M.
    Batalygin S.N.
    Russian Electrical Engineering, 2007, 78 (12) : 649 - 657
  • [6] VACUUM INTERRUPTERS FOR HIGH-VOLTAGE TRANSMISSION CIRCUIT BREAKERS
    KURTZ, DR
    SOFIANEK, JC
    CROUCH, DW
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, 94 (04): : 1094 - 1094
  • [7] Adopting Circuit Breakers for High-Voltage dc Networks
    Jovcic, Dragan
    Tang, Guangfu
    Pang, Hui
    IEEE POWER & ENERGY MAGAZINE, 2019, 17 (03): : 82 - 93
  • [8] Development of high-voltage vacuum circuit breakers in China
    Liu, Zhiyuan
    Wang, Jimei
    Xiu, Shixin
    Wang, Zhongyi
    Yuan, Shun
    Jin, Li
    Zhou, Heming
    Yang, Ren
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2007, 35 (04) : 856 - 865
  • [9] Electromagnet operation characteristic in high-voltage circuit breakers
    Piao, Jixing
    Zhu, Peng
    Xu, Guozheng
    Huang, Yulong
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2006, 46 (10): : 1669 - 1672
  • [10] ACOUSTIC DIAGNOSIS OF HIGH-VOLTAGE CIRCUIT-BREAKERS
    RUNDE, M
    AURUD, T
    LUNDGAARD, LE
    OTTESEN, GE
    FAUGSTAD, K
    BOGGS, SA
    IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (03) : 1306 - 1315