Response-time of Pyroelectric Detector Simulator

被引:0
|
作者
Klyuchnyk, Igor [1 ]
Bondarenko, Alexander
Galkin, Pavlo [1 ]
Golovkina, Lydmila [1 ]
Khoroshaylo, Yuriy [1 ]
Shtanko, Valentina [1 ]
Kravets, Nikolay [2 ]
机构
[1] Kharkiv Natl Univ Radioelect, Dept Design & Operat Elect Devices, Kharkiv, Ukraine
[2] Kharkiv Natl Univ Radioelect, Dept Philosophy, Kharkiv, Ukraine
关键词
dynamic response; transient; pyroelectric converter; mathematical model; pyroelectric response; pyroelectric converter simulator;
D O I
10.1109/MMA52675.2021.9610920
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A feature of thermal converters based on the pyroelectric effect is their reaction exclusively to a change in the intensity of the radiation flux incident on them. Therefore, for many applications of pyroconverters, the key point is their dynamic characteristics, which are estimated from the transient processes of pyrodetectors. On the basis of a mathematical model of a pyroelectric converter, a simulator of its temporal characteristics has been developed, which makes it possible to study the transient processes of both designed pyrodetectors and, if necessary, determine the parameters of already manufactured products.
引用
收藏
页码:48 / 52
页数:5
相关论文
共 50 条
  • [1] Time response analysis of a pyroelectric detector
    Natl Cheng Kung Univ, Tainan, Taiwan
    Ferroelectrics, 1-4 (257-268):
  • [2] Time response analysis of a pyroelectric detector
    Chen, FY
    Fang, YK
    Hsu, CY
    Chen, JR
    FERROELECTRICS, 1997, 200 (1-4) : 257 - 268
  • [3] TESTING RESPONSE-TIME OF CAPNOMETERS USING A CAPNOGRAM SIMULATOR
    ORR, JA
    WESTENSKOW, DR
    TURNER, RB
    ANESTHESIOLOGY, 1994, 81 (3A) : A586 - A586
  • [4] CUTTING RESPONSE-TIME
    不详
    COMPUTER-AIDED ENGINEERING, 1995, 14 (09): : 10 - 12
  • [5] RESPONSE-TIME DISCRIMINATION
    WU, RM
    BROWN, CR
    PAGEREY, PD
    ERGONOMICS, 1982, 25 (06) : 563 - 564
  • [6] WINDOWLESS X-RAY-DETECTOR WITH 50-PS RESPONSE-TIME
    CAMPBELL, DE
    LAIRD, WB
    SCHWINN, TD
    TIRSELL, KG
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (08): : 1098 - 1098
  • [7] Advanced Simulator of Pyroelectric Detector Circuits and Associated Signal Processing
    Efthymiou, Spyros
    Ozanyan, Krikor B.
    IEEE AFRICON 2011, 2011,
  • [8] RESPONSE-TIME OF ORGANIZATIONS
    ENGWALL, L
    JOURNAL OF MANAGEMENT STUDIES, 1976, 13 (01) : 1 - 15
  • [9] USE OF A COMPUTER-CONTROLLED FIREARMS TRAINING SIMULATOR IN PERCEPTION RESPONSE-TIME EXPERIMENTS
    SEYMOUR, GO
    STAHL, JM
    SWANN, GB
    ROSS, D
    BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 1995, 27 (02): : 148 - 151
  • [10] PYROELECTRIC COEFFICIENT DIRECT MEASUREMENT TECHNIQUE AND APPLICATION TO A NSEC RESPONSE TIME DETECTOR
    BYER, RL
    ROUNDY, CB
    FERROELECTRICS, 1972, 3 (2-3-) : 333 - &