Performance Development and Evaluation of Solar Air Collector with Novel Phase Change Material

被引:2
|
作者
Vedanarayanan, V. [1 ]
Srinivasan, J. Dilli [2 ]
Arulvendhan, K. [2 ]
Kumaran, P. Thirusenthil [3 ]
Selvakumar, R. [4 ]
Maridurai, T. [5 ]
Sudhakar, M. [6 ]
Al Obaid, Sami [7 ]
Alfarraj, Saleh [8 ]
Raj, M. M. [9 ]
Raghavan, Ishwarya Komalnu [10 ]
机构
[1] Sathyabama Inst Sci & Technol, Dept Elect & Commun Engn, Chennai 600119, Tamil Nadu, India
[2] SRM Inst Sci & Technol, Dept Elect & Elect Engn, Ramapuram 600089, Tamil Nadu, India
[3] Rajalakshmi Engn Coll, Dept Elect & Elect Engn, Thandalam 602105, Tamil Nadu, India
[4] K L Univ, Koneru Lakshmaiah Educ Fdn, Dept Elect & Commun Engn, Guntur 522502, Andhra Pradesh, India
[5] SIMATS, Saveetha Sch Engn, Dept Mech Engn, Chennai, Tamil Nadu, India
[6] Sri Sairam Engn Coll, Dept Mech Engn, Chennai 600044, Tamil Nadu, India
[7] King Saud Univ, Coll Sci, Dept Bot & Microbiol, POB 2455, Riyadh 11451, Saudi Arabia
[8] King Saud Univ, Coll Sci, Zool Dept, Riyadh 11451, Saudi Arabia
[9] Seoul Natl Univ Sci & Technol, Dept Mech Engn, Seoul, South Korea
[10] Hawassa Univ, Inst Technol, Fac Mfg, Dept Electromech Engn, Hawassa, Ethiopia
关键词
GLASS EVACUATED TUBE; THERMAL PERFORMANCE; HEAT-STORAGE; PCM STORAGE; SYSTEMS; ENERGY; FIELD; UNIT;
D O I
10.1155/2022/3787141
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Experiments were carried out on an evacuated tube solar air collector connected to intrinsic thermal power storage to provide warm air unless solar radiation was available. As a phase change material, stearic acid was employed (PCM). Water has been used as a base fluid for converting sunlight into electricity gain to warm air, and the solar collector's manifold was connected to the intrinsic thermal energy store. The most significant temperature variation between warm air and ecologic air was 38 degrees C and 22 degrees C, respectively, during direct and indirect solar radiation. A circular fin arrangement was used to achieve a flow rate of 0.020 kg s(-1). The efficiency of minimum airflow rates (0.020 kg s(-1)) was 0.08-0.48 times that of maximum airflow rates (0.04 kg s(-1)). Because of the PCM's better heat-storing capability, this system has a benefit over sensible storage systems in that it may be used after sunset.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Performance Development and Evaluation of Solar Air Collector with Novel Phase Change Material
    Vedanarayanan, V.
    Srinivasan, J. Dilli
    Arulvendhan, K.
    Kumaran, P. Thirusenthil
    Selvakumar, R.
    Maridurai, T.
    Sudhakar, M.
    Al Obaid, Sami
    Alfarraj, Saleh
    Raj, M.M.
    Raghavan, Ishwarya Komalnu
    International Journal of Photoenergy, 2022, 2022
  • [2] Annual Performance Evaluation of Evacuated Tube Solar Air Collector With Phase Change Material
    Mehla, Neeraj
    Kumar, Manoj
    Yadav, Avadhesh
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (03):
  • [3] Performance of compound parabolic concentrator solar air flat plate collector using phase change material
    Yousif, Mohammed Nazaer
    Alomar, Omar Rafae
    Saleem, Ahmed Mustafa
    APPLIED THERMAL ENGINEERING, 2024, 240
  • [4] Performance prediction of innovative solar air collector (ISAC) with phase change material using the ann approach
    Mehla N.
    Singh B.
    Kumar A.
    Mehla, Neeraj (neerajmehla471@gmail.com), 1600, Begell House Inc. (22): : 65 - 83
  • [5] Thermal performance of a water-phase change material solar collector
    Kürklü, A
    Özmerzi, A
    Bilgin, S
    RENEWABLE ENERGY, 2002, 26 (03) : 391 - 399
  • [6] Performance study on phase change material integrated solar still coupled with solar collector
    Maridurai, T.
    Rajkumar, S.
    Arunkumar, M.
    Mohanavel, V.
    Arul, K.
    Madhesh, D.
    Subbiah, Ram
    MATERIALS TODAY-PROCEEDINGS, 2022, 59 : 1319 - 1323
  • [7] Performance analysis of a novel hydrogen production system incorporated with hybrid solar collector and phase change material
    Senthilraja, S.
    Gangadevi, R.
    Koten, Hasan
    Marimuthu, R.
    Awad, Mohamed M.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (62) : 26223 - 26237
  • [8] Influence of nocturnal thermal insulation on thermal performance improvement of solar air collector with phase-change material
    Bo, Renfei
    Hu, Chenxi
    Fu, Wenkai
    Meng, Xi
    Mao, Wei
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 47
  • [9] Optimization of thermal performance of building integrated solar collector with Phase Change Material
    Bouhssine, Z.
    Faraji, M.
    Najam, M.
    El Alami, M.
    2014 INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC), 2014, : 720 - 722
  • [10] Thermal Performance of a Domestic Chromium Solar Water Collector with Phase Change Material
    Koyuncu, Turhan
    Lule, Fuat
    WORLD CONFERENCE ON TECHNOLOGY, INNOVATION AND ENTREPRENEURSHIP, 2015, : 2430 - 2442