Second-look arthroscopic findings and clinical outcomes of meniscal repair with concomitant anterior cruciate ligament reconstruction: comparison of suture and meniscus fixation device

被引:7
|
作者
Seo, Seung-Suk [1 ]
Kim, Chang-Wan [3 ]
Lee, Chang-Rack [3 ]
Park, Dae-Hyun [3 ]
Kwon, Yong-Uk [3 ]
Kim, Ok-Gul [2 ]
Kim, Chang-Kyu [1 ]
机构
[1] Haeundae Bumin Hosp, Dept Orthoped Surg, 584 Haeundae Ro, Busan 48094, South Korea
[2] Bumin Hosp, Dept Orthoped Surg, 59 Mandeok Daero, Busan 46555, South Korea
[3] Inje Univ, Coll Med, Busan Paik Hosp, Dept Orthoped Surg, 75 Bokji Ro, Busan 47392, South Korea
关键词
Anterior cruciate ligament; Meniscus; Repair; Second-look arthroscopy; Outcomes; POSTERIOR MOTION; MEDIAL MENISCUS; MENISCECTOMY; KNEE;
D O I
10.1007/s00402-020-03466-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction The purpose of this study was to evaluate the healing rate of repaired meniscus and functional outcomes of patients who received all-inside meniscal repair using sutures or devices with concomitant arthroscopic anterior cruciate ligament (ACL) reconstruction. Materials and methods Among the patients who have ACL tear and posterior horn tear of medial or lateral meniscus, 61 knees who received all-inside repair using sutures (suture group, n = 28) or meniscal fixation devices (device group, n = 33) with concomitant ACL reconstruction during the period from January 2012 to December 2015, followed by second-look arthroscopy, were retrospectively reviewed. Healing status of the repair site was assessed by second-look arthroscopy. Through the clinical assessment, clinical success (negative medial joint line tenderness, no history of locking or recurrent effusion, and negative McMurray test) rate of the repaired meniscus and functional outcomes (International Knee Documentation Committee subjective score and Lysholm knee score) was evaluated. Results In a comparison of healing status of repaired meniscus evaluated by second-look arthroscopy, suture group had 23 cases of complete healing (82.1%), 4 cases of incomplete healing (14.3%), and 1 case of failure (3.6%). Device group had 18 cases of complete healing (54.5%), 4 cases of incomplete healing (24.2%), and 7 cases of failure (21.2%) (p = 0.048). Clinical success rate of the meniscal repair was 89.3% (25 cases) and 81.8% (27 cases) in suture group and device group, respectively (p = 0.488). No significant difference of functional outcomes was observed between the two groups (p > 0.05, both parameters). Conclusions Among the patients who received meniscal repair with concomitant ACL reconstruction, suture group showed better healing status of repaired meniscus based on the second-look arthroscopy than device group. However, no significant between-group difference of clinical success rate and functional outcomes was observed.
引用
收藏
页码:1243 / 1244
页数:2
相关论文
共 50 条
  • [1] Second-look arthroscopic findings and clinical outcomes of meniscal repair with concomitant anterior cruciate ligament reconstruction: comparison of suture and meniscus fixation device
    Seung-Suk Seo
    Chang-Wan Kim
    Chang-Rack Lee
    Dae-Hyun Park
    Yong-Uk Kwon
    Ok-Gul Kim
    Chang-Kyu Kim
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 1243 - 1244
  • [2] Second-look arthroscopic findings and clinical outcomes of meniscal repair with concomitant anterior cruciate ligament reconstruction: comparison of suture and meniscus fixation device
    Seo, Seung-Suk
    Kim, Chang-Wan
    Lee, Chang-Rack
    Park, Dae-Hyun
    Kwon, Yong-Uk
    Kim, Ok-Gul
    Kim, Chang-Kyu
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (03) : 365 - 372
  • [3] Second-look arthroscopic findings and clinical outcomes of meniscal repair with concomitant anterior cruciate ligament reconstruction: comparison of suture and meniscus fixation device
    Seung-Suk Seo
    Chang-Wan Kim
    Chang-Rack Lee
    Dae-Hyun Park
    Yong-Uk Kwon
    Ok-Gul Kim
    Chang-Kyu Kim
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 365 - 372
  • [4] Concerning Seo et al.: “Second-look arthroscopic findings and clinical outcomes of meniscal repair with concomitant anterior cruciate ligament reconstruction: comparison of suture and meniscus fixation device”
    Mingjin Zhong
    Wei Lu
    Weimin Zhu
    Kan Ouyang
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 1241 - 1242
  • [5] Concerning Seo et al.: "Second-look arthroscopic findings and clinical outcomes of meniscal repair with concomitant anterior cruciate ligament reconstruction: comparison of suture and meniscus fixation device"
    Zhong, Mingjin
    Lu, Wei
    Zhu, Weimin
    Ouyang, Kan
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (09) : 1241 - 1242
  • [6] Second-Look Arthroscopic Evaluations of Meniscal Repairs Associated With Anterior Cruciate Ligament Reconstruction
    Kanto, Ryo
    Yamaguchi, Motoi
    Sasaki, Ken
    Matsumoto, Akio
    Nakayama, Hiroshi
    Yoshiya, Shinichi
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (10): : 2868 - 2877
  • [7] Clinical outcomes and second-look arthroscopic findings of anterior cruciate ligament reconstruction with autograft, hybrid graft, and allograft
    Xiaozuo Zheng
    Yang Hu
    Peng Xie
    Tong Li
    Yu-e Feng
    Juyuan Gu
    Shijun Gao
    Journal of Orthopaedic Surgery and Research, 14
  • [8] Clinical outcomes and second-look arthroscopic findings of anterior cruciate ligament reconstruction with autograft, hybrid graft, and allograft
    Zheng, Xiaozuo
    Hu, Yang
    Xie, Peng
    Li, Tong
    Feng, Yu-e
    Gu, Juyuan
    Gao, Shijun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (01)
  • [9] Comparison of second-look arthroscopic findings and clinical results according to the amount of preserved remnant in anterior cruciate ligament reconstruction
    Kim, Min Kyu
    Lee, Sung Rak
    Ha, Jeong Ku
    Ra, Ho Jong
    Kim, Sang Bum
    Kim, Jin Goo
    KNEE, 2014, 21 (03): : 774 - 778
  • [10] Second-look arthroscopic findings and clinical results after polyethylene terephthalate augmented anterior cruciate ligament reconstruction
    Johannes Struewer
    Ewgeni Ziring
    Bernd Ishaque
    Turgay Efe
    Tim Schwarting
    Benjamin Buecking
    Karl F. Schüttler
    Steffen Ruchholtz
    Thomas M. Frangen
    International Orthopaedics, 2013, 37 : 327 - 335