A modified index for control performance assessment

被引:0
|
作者
Horch, A [1 ]
Isaksson, AJ [1 ]
机构
[1] Royal Inst Technol, S-10044 Stockholm, Sweden
关键词
control performance assessment; monitoring; pole placement; internal model control; robustness;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A control performance index which relates actual output variance to minimal achievable variance was first presented by Harris [3]. In the present paper, a modification of that index is applied. Instead of comparing to minimum variance control - which corresponds to placing all closed-loop poles in the origin - one pole is placed using either control design guidelines or additionally available process knowledge. Some possible choices of the free closed-loop pole are discussed. Based on this modified closed-loop system, a performance index can be calculated which relates actual output variance to the minimum achievable variance using the modified closed-loop system. It is shown that for the calculation of this index no other information apart from the measured process output and the time-delay is necessary. The original Harris index and the proposed modified index are computed using data from industrial processes.
引用
收藏
页码:3430 / 3434
页数:5
相关论文
共 50 条
  • [1] A modified index for control performance assessment
    Horch, A
    Isaksson, AJ
    JOURNAL OF PROCESS CONTROL, 1999, 9 (06) : 475 - 483
  • [2] Control Performance Assessment and Improvement with A New Performance Index
    Meng, Q. W.
    Gu, J. Q.
    Zhong, Zh F.
    Niu, Y. G.
    2013 25TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2013, : 4081 - 4084
  • [3] Neural generalized prediction control with modified performance index
    Rao, D. N.
    Murthy, M. R. K.
    Rao, S. M.
    Harshal, D. N.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART I-JOURNAL OF SYSTEMS AND CONTROL ENGINEERING, 2006, 220 (I7) : 531 - 537
  • [4] Assessment of modified myocardial performance index in foetuses with growth restriction
    Silva, Carolina Pacheco
    Araujo Junior, Edward
    Zamith, Marina Maccagnano
    Rabachini Caetano, Ana Carolina
    Perez Zamarian, Ana Cristina
    Cavalcante, Rafael Oliveira
    Moron, Antonio Fernandes
    Machado Nardozza, Luciano Marcondes
    MEDICAL ULTRASONOGRAPHY, 2016, 18 (02) : 207 - 213
  • [5] Assessment of Automatic Generation Control Performance Index Criteria
    Rahimi, Kaveh
    Famouri, Parviz
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,
  • [6] Design of Switching Control Systems Using Control Performance Assessment Index
    Moridi, Arefeh
    Armaghan, Shabnam
    Sedigh, Ali Khaki
    Choobkar, Saleheh
    WORLD CONGRESS ON ENGINEERING, WCE 2011, VOL II, 2011, : 1339 - 1342
  • [7] Prospective longitudinal assessment of the fetal left modified Myocardial Performance Index
    MacDonald, Teresa M.
    Robinson, Alice J.
    Walker, Susan P.
    Hui, Lisa
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2019, 32 (05): : 760 - 767
  • [8] OPTIMAL CONTROL OF LINEAR-SYSTEMS WITH A MODIFIED QUADRATIC PERFORMANCE INDEX
    MUELLER, GS
    WANG, MJ
    INTERNATIONAL JOURNAL OF CONTROL, 1975, 21 (04) : 609 - 624
  • [9] Data-driven performance assessment of multivariable control loops using a modified Hurst exponent-based index
    Khosroshahi, Maryam
    Poshtan, Javad
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART I-JOURNAL OF SYSTEMS AND CONTROL ENGINEERING, 2021, 235 (06) : 769 - 780
  • [10] PERFORMANCE OF MODIFIED PALMER INDEX
    BHALME, HN
    MOOLEY, DA
    ARCHIV FUR METEOROLOGIE GEOPHYSIK UND BIOKLIMATOLOGIE SERIE B-KLIMATOLOGIE UMWELTMETEOROLOGIE STRAHLUNGSFORSCHUNG, 1979, 27 (04): : 281 - 295