In vivo evaluation of an intravascular receiver coil for MRI at 1.0 Tesla

被引:2
|
作者
Matschl, V
Heverhagen, JT
Kalinowski, M
Alfke, H
Jaensch, HJ
Wagner, HJ
Klose, KJ
机构
[1] Univ Marburg, Dept Diagnost Radiol, Marburg, Germany
[2] Univ Marburg, Dept Phys, Marburg, Germany
[3] Univ Marburg, Ctr Mat Sci, Marburg, Germany
来源
VASA-JOURNAL OF VASCULAR DISEASES | 2001年 / 30卷 / 01期
关键词
intravascular MR-receiver-coil; high resolution MR; vessel wall morphology;
D O I
10.1024/0301-1526.30.1.9
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Evaluation of the applicability of intravascular radiofrequency receiver coils by means of a pig in-vivo-experiment for the detection of vessel wall structures at 1.0 Tesla. Materials and methods: The intravascular receiver coil was constructed according to a well evaluated single-loop-design, which was mounted onto a balloon catheter for angioplasty. Under fluoroscopy control the balloon catheter was placed in the common carotid artery of a porcine. Images were obtained in a 1.0 Tesla clinical scanner using a fast-spin-echo-, a gradient-echo- and a high resolution spin-echo-sequence. Histological examinations were obtained to detect any vessel wall damage associated with the use of the receiver coil. Results: High qualtity images with a resolution up to 0.16*0.12 mm(2) could be acquired in aquisition times of about 5 minutes. Subtle intra- and extra-vascular structures such as the balloon, irregularities of the vessel wall or bordering structures could be visualized The histological examination showed no vessel damage due to the application of the int avascular receiver coil. Conclusions: The application of intravascular receiver coils for the visualization of the vessel wall is feasible at 1.0 Tesla without histologically detectable trauma to the vessel wall.
引用
收藏
页码:9 / 13
页数:5
相关论文
共 50 条
  • [1] High resolution intravascular MRI and MRS by using a catheter receiver coil
    Atalar, E
    Bottomley, PA
    Ocali, O
    Correia, LCL
    Kelemen, MD
    Lima, JAC
    Zerhouni, EA
    MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) : 596 - 605
  • [2] A novel nonobstructive intravascular MRI coil - In vivo imaging of experimental atherosclerosis
    Worthley, SG
    Helft, G
    Fuster, V
    Fayad, ZA
    Shinnar, M
    Minkoff, LA
    Schechter, C
    Fallon, JT
    Badimon, JJ
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2003, 23 (02) : 346 - 350
  • [3] Imaging performance of a dedicated radiation transparent RF coil on a 1.0 Tesla inline MRI-linac
    Liney, G. P.
    Dong, B.
    Weber, E.
    Rai, R.
    Destruel, A.
    Garcia-Alvarez, R.
    Manton, D. J.
    Jelen, U.
    Zhang, K.
    Barton, M.
    Keall, P.
    Crozier, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (13):
  • [4] MRI for patients with pacemakers: In vitro and in vivo evaluation at 0.5 Tesla
    Sommer, T
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (06): : 634 - 635
  • [5] MRI for patients with pacemakers: In vitro and in vivo evaluation of 0.5 Tesla
    Moshage, W
    Achenbach, S
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (06): : 634 - 634
  • [6] Initial clinical experience with a quadrupole butterfly coil for spinal injection interventions in an open MRI system at 1.0 tesla
    Jonczyk, Martin
    Hamm, Bernd
    Heinrich, Andreas
    Thomas, Andreas
    Rathke, Hendrik
    Schnackenburg, Bernhard
    Guettler, Felix
    Teichgraeber, Ulf K. M.
    de Bucourt, Maximilian
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 (01): : 39 - 45
  • [7] Quality Comparison of 3 Tesla multiparametric MRI of the prostate using a flexible surface receiver coil versus conventional surface coil plus endorectal coil setup
    T. Ullrich
    M. D. Kohli
    M. A. Ohliger
    K. Magudia
    S. S. Arora
    T. Barrett
    L. K. Bittencourt
    D. J. Margolis
    L. Schimmöller
    B. Turkbey
    A. C. Westphalen
    Abdominal Radiology, 2020, 45 : 4260 - 4270
  • [8] Quality Comparison of 3 Tesla multiparametric MRI of the prostate using a flexible surface receiver coil versus conventional surface coil plus endorectal coil setup
    Ullrich, T.
    Kohli, M. D.
    Ohliger, M. A.
    Magudia, K.
    Arora, S. S.
    Barrett, T.
    Bittencourt, L. K.
    Margolis, D. J.
    Schimmoeller, L.
    Turkbey, B.
    Westphalen, A. C.
    ABDOMINAL RADIOLOGY, 2020, 45 (12) : 4260 - 4270
  • [9] In Vivo MRI-Based Dental Impression Using an Intraoral RF Receiver Coil
    Tymofiyeva, O.
    Rottner, K.
    Gareis, D.
    Boldt, J.
    Schmid, F.
    Lopez, M. A.
    Richter, E-J.
    Jakob, P. M.
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2008, 33B (04) : 244 - 251
  • [10] In vivo high-resolution MRI of experimental atherosclerosis assessed by a non-obstructive intravascular MRI coil
    Helft, G
    Worthley, SG
    Shinnar, M
    Minkoff, LO
    Fayad, ZA
    Fuster, V
    Badimon, JJ
    EUROPEAN HEART JOURNAL, 2001, 22 : 568 - 568