Seismic response and energy dissipation of 3D complex steel buildings considering the influence of interior semi-rigid connections: low- medium- and high-rise

被引:5
|
作者
Reyes-Salazar, Alfredo [1 ]
Sauceda-Pimentel, Jose M. [1 ]
Ruiz, Sonia E. [2 ]
Bojorquez, Eden [1 ]
Bojorquez, Juan [1 ]
机构
[1] Univ Autonoma Sinaloa, Fac Ingn, Ciudad Univ, Culiacan, Sinaloa, Mexico
[2] Univ Nacl Autonoma Mexico, Inst Ingn, Ciudad Univ, Ciudad De Mexico, Mexico
关键词
Steel buildings; Moment resisting frames; Gravity frames; Nonlinear behavior; Semi-rigid connections; Dissipated energy; Seismic loading; BOLTED-ANGLE CONNECTIONS; MOMENT-RESISTING FRAMES; TIME-HISTORY ANALYSIS; BEHAVIOR; DESIGN; PERFORMANCE; LOADS;
D O I
10.1007/s10518-018-0405-x
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
A numerical investigation regarding the seismic behavior of complex-3D steel buildings with perimeter moment resisting frames (PMRF) and interior gravity frames (GF) is conducted. The interior connections are assumed to be first perfectly pinned (PP) and then semi-rigid (SR); the two model responses are compared. Three steel building models representing low-, medium- and high-rise buildings, and several strong motions are used. The relative stiffness of SR connections is calculated according to the Richard Model and the Beam Line Theory. The Ruaumoko Computer Program is used to perform the required step-by-step nonlinear seismic analysis. Results indicate that interstory shears and interstory displacements at PMRF may be significantly reduced when interior connections are modeled as SR. Average reductions of up to 20, 46 and 11% are observed for interstory shears, for low-, medium-, and high-rise buildings, respectively. The corresponding reductions for interstory displacements are about 14, 44 and 15%. The contribution of GF to the lateral resistance is considerable, which significantly increases when the connections are modeled as SR; relative contributions larger than 80% are observed. The dissipated energy (DE) at PMRF is larger for the buildings with PP than for the buildings with SR connections indicating that damage at PMRF is reduced. Thus, the effect of the stiffness and the DE at interior connections should not be ignored. However, the design of some elements, particularly columns of the GF, has to be revised; these members may not be able to support the loads produced by the neglected lateral contribution if they are not properly designed.
引用
收藏
页码:5557 / 5590
页数:34
相关论文
共 3 条
  • [1] Seismic response and energy dissipation of 3D complex steel buildings considering the influence of interior semi-rigid connections: low- medium- and high-rise
    Alfredo Reyes-Salazar
    José M. Sauceda-Pimentel
    Sonia E. Ruiz
    Edén Bojórquez
    Juan Bojorquez
    Bulletin of Earthquake Engineering, 2018, 16 : 5557 - 5590
  • [2] Seismic Response of 3D Steel Buildings considering the Effect of PR Connections and Gravity Frames
    Reyes-Salazar, Alfredo
    Bojorquez, Eden
    Haldar, Achintya
    Lopez-Barraza, Arturo
    Rivera-Salas, J. Luz
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [3] Seismic response of complex 3D steel buildings with welded and post-tensioned connections
    Reyes-Salazar, Alfredo
    Ruiz, Sonia E.
    Bojorquez, Eden
    Bojorquez, Juan
    Llanes-Tizoc, Mario D.
    EARTHQUAKES AND STRUCTURES, 2016, 11 (02) : 217 - 243