The Value of Intraoperative Transesophageal Echocardiography in Patients Undergoing Aortic Valve Replacement

被引:0
|
作者
Weisenberg, Daniel [1 ,2 ]
Sagie, Alik [1 ,2 ]
Vaturi, Mordehay [1 ,2 ]
Monakier, Daniel [1 ,2 ]
Sharoni, Erez [3 ]
Porat, Eyal [3 ]
Shapira, Yaron [1 ,2 ]
机构
[1] Tel Aviv Univ, Sackler Sch Med, Dept Cardiol, Valvular Clin,Rabin Med Ctr, Petah Tiqwa, Israel
[2] Tel Aviv Univ, Sackler Sch Med, Dept Cardiol, Dan Sheingarten Echocardiog Unit,Rabin Med Ctr, Petah Tiqwa, Israel
[3] Tel Aviv Univ, Sackler Sch Med, Dept Cardiothorac Surg, Rabin Med Ctr, Petah Tiqwa, Israel
来源
JOURNAL OF HEART VALVE DISEASE | 2011年 / 20卷 / 05期
关键词
IMPACT;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: While the role of intraoperative transesophageal echocardiography (IOTEE) in valve repair surgery is well documented, its value in patients undergoing valve replacement is debatable. The study aim was to assess the impact of IOTEE on the management of a large cohort of patients referred for aortic valve replacement (AVR). Methods: The departmental echocardiography database for patients undergoing AVR with IOTEE between April 1999 and September 2006 at the authors' institution was reviewed. Patients with a diagnosis of infective endocarditis, aortic dissection, or those in whom a composite graft was implanted, were excluded from the study. Results: The study group included 604 patients (319 males, 285 females; mean age 70 11 years) who underwent AVR for either predominant aortic stenosis (n = 520; 86.1%) or aortic regurgitation (n = 84; 13.9%). Pre-pump IOTEE was performed in 440 patients (72.8%), and post-pump IOTEE in 586 (97.0%). Overall major preoperative findings influencing the operative plan were found in 106 of the 440 patients (24.1%); decisions regarding the mitral valve were the most frequent. The post-pump study revealed unexpected findings requiring a second pump run in 20 patients (3.4%), of whom nine cases (1.5%) applied to the replaced aortic prostheses (paravalvular leak in five patients, coronary obstruction by an aortic bioprosthesis in two, and detection and closure of a pseudoaneurysm in the mitral-aortic fibrosa and incompetent bioprosthesis in one patient each). Eleven patients (1.8%) required a second pump run because of failed mitral/tricuspid repair or hemodynamic compromise. Conclusion: The main use of a routine application of IOTEE among patients undergoing AVR was to detect additional lesions preoperatively, and technical failures postoperatively.
引用
收藏
页码:540 / 544
页数:5
相关论文
共 50 条
  • [1] Impact of intraoperative transesophageal echocardiography among patients undergoing aortic valve replacement for aortic stenosis
    Nowrangi, SK
    Connolly, HM
    Freeman, WK
    Click, RL
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2001, 14 (09) : 863 - 866
  • [2] Impact of intraoperative transesophageal echocardiography in patients undergoing valve replacement
    Shapira, Y
    Vaturi, M
    Weisenberg, DE
    Raanani, E
    Sahar, G
    Snir, E
    Battler, A
    Vidne, BA
    Sagie, A
    ANNALS OF THORACIC SURGERY, 2004, 78 (02): : 579 - 584
  • [3] Current Usefulness of Transesophageal Echocardiography in Patients Undergoing Transcatheter Aortic Valve Replacement
    de Agustin, Jose Alberto
    Pozo Osinalde, Eduardo
    Olmos, Carmen
    Mahia Casado, Patricia
    Marcos-Alberca, Pedro
    Luaces, Maria
    Gomez de Diego, Jose Juan
    Nombela-Franco, Luis
    Jimenez-Quevedo, Pilar
    Tirado-Conte, Gabriela
    Collado Yurrita, Luis
    Fernandez-Ortiz, Antonio
    Perez-Villacastin, Julian
    La Canna, Giovanni
    Nicolosi, Gian Luigi
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (24)
  • [4] Intraoperative transesophageal echocardiography in valve replacement surgery
    Rosenhek, R
    Binder, T
    Maurer, G
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2002, 19 (08): : 701 - 707
  • [5] MALLORY-WEISS TEAR COMPLICATING INTRAOPERATIVE TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN A PATIENT UNDERGOING AORTIC-VALVE REPLACEMENT
    DEWHIRST, WE
    STRAGAND, JJ
    FLEMING, BM
    ANESTHESIOLOGY, 1990, 73 (04) : 777 - 778
  • [6] Implications of intraoperative transesophageal echocardiography detection of ruptured sinus of valsalva in a patient with severe aortic regurgitation undergoing aortic valve replacement
    Neema, Praveen Kumar
    Sethuraman, Manikandan
    Rathod, Ramesh Chandra
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2006, 20 (06) : 847 - 849
  • [7] Iatrogenic Mitral Valve Injury During Aortic Valve Replacement: Importance of Intraoperative Transesophageal Echocardiography
    Steiman, Jennifer
    Chaney, Mark A.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (03) : 586 - 586
  • [8] Posterior Aortic Root Enlargement During Aortic Valve Replacement: Role of Intraoperative Transesophageal Echocardiography
    Aggarwal, Neelam
    Gadhinglajkar, Shrinivas V.
    Panicker, Varghese T.
    Sreedhar, Rupa
    Babu, Saravana
    Mathew, Deepak Gregory
    Prasannakumar, Chirag S.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2017, 31 (04) : 1312 - 1317
  • [9] TRANSESOPHAGEAL ECHOCARDIOGRAPHY FOR TRANSCATHETER AORTIC VALVE REPLACEMENT
    Lerakis, S.
    Block, P.
    Thourani, V.
    Guyton, R.
    Babaliaros, V.
    CARDIOLOGY, 2013, 125 : 238 - 238
  • [10] INTRAOPERATIVE TRANSESOPHAGEAL ECHOCARDIOGRAPHY FAILS TO PREDICT IMPROVEMENT OF MITRAL REGURGITATION IN AORTIC-VALVE REPLACEMENT PATIENTS
    HANEY, MF
    HARRIS, KM
    JAYNE, JE
    PLEHN, JF
    MARRIN, CAS
    NUGENT, WC
    PLUME, SK
    GRIFFIN, BP
    CIRCULATION, 1992, 86 (04) : 700 - 700