Measurements of particle concentrations in an SF6 arc plasma of an electrical circuit-breaker

被引:0
|
作者
Ciobanu, SS [1 ]
Fleurier, C [1 ]
Hong, D [1 ]
Fiévet, C [1 ]
机构
[1] Univ Orleans, CNRS, GREMI, F-45067 Orleans 2, France
关键词
D O I
暂无
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Measurements of particle temperatures and concentrations are performed for a transient and unstable plasma are in a circuit breaker operated in a 3 atm SF6 gas. The large current intensity causes an important vaporization of the electrodes so that the plasma develops in a mixture of SF, and Cu. Time resolved photographs of the are obtained with interference filters show a compact and homogeneous zone dominated by a S+-F plasma, and an inhomogeneous zone close to the electrodes dominated by Cu. Average electron densities and temperatures and also the total number of the different emitting atoms or ions are determined in the two zones by spectroscopical methods using simultaneous measurements with time resolution at high and low spectral resolution. particle concentrations are obtained after an estimate of the average volumes of the different plasma zones.
引用
收藏
页码:247 / 254
页数:8
相关论文
共 50 条
  • [1] A ROTATING-ARC SF6 CIRCUIT-BREAKER
    PARRY, J
    ELECTRONICS AND POWER, 1981, 27 (10): : 725 - 727
  • [2] MODELING OF THE SF6 CIRCUIT-BREAKER ARC AND OF ITS INTERACTION WITH THE CIRCUIT
    GLEIZES, A
    ROBERT, T
    GONZALEZ, JJ
    PONS, A
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1993, 26 (09) : 1439 - 1444
  • [3] SF6 CIRCUIT-BREAKER DESIGN AND PERFORMANCE
    STEWART, JS
    ELECTRONICS AND POWER, 1979, 25 (02): : 121 - 126
  • [4] SF6 CIRCUIT-BREAKER ARC MODELING - INFLUENCE OF THE ELECTRIC-FIELD ON THE ELECTRICAL-CONDUCTIVITY
    GONZALEZ, JJ
    GLEIZES, A
    KRENEK, P
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1994, 27 (05) : 985 - 993
  • [5] METALCLAD SF6 CIRCUIT-BREAKER TYPE ECK
    MAUTHE, G
    OTTISCHNIG, R
    SCHMIDT, KD
    BROWN BOVERI REVIEW, 1970, 57 (12): : 562 - +
  • [6] ANALYSIS OF THE DIELECTRIC STRENGTH OF AN SF6 CIRCUIT-BREAKER
    TREPANIER, JY
    REGGIO, M
    LAUZE, Y
    JEANJEAN, R
    IEEE TRANSACTIONS ON POWER DELIVERY, 1991, 6 (02) : 809 - 815
  • [7] A SPECTROSCOPIC INVESTIGATION OF ELECTRODE MATERIAL ENTRAINED INTO THE EXTINGUISHING ARC OF AN SF6 CIRCUIT-BREAKER
    JONES, GR
    HU, W
    ELKHOLY, SM
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1988, 21 (09) : 1414 - 1420
  • [8] SYNTHETIC CAPACITOR SWITCHING TESTS ON A SF6 CIRCUIT-BREAKER
    BERKEBILE, LE
    PFLEIDERER, R
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1980, 99 (01): : 16 - 16
  • [9] Medium voltage SF6 circuit-breaker are model application
    Pinto, LC
    Zanetta, LC
    ELECTRIC POWER SYSTEMS RESEARCH, 2000, 53 (01) : 67 - 71
  • [10] SF6 or vacuum? Choosing the right MV circuit-breaker
    Leonhardt, Guenter
    Marchi, Mauro
    Rivetti, Giandomenico
    ABB Review, 2000, (04): : 26 - 34