Atrial fibrillation variability on long-term monitoring of implantable cardiac rhythm management devices

被引:2
|
作者
Kaplan, Rachel M. [1 ]
Ziegler, Paul D. [2 ]
Koehler, Jodi [2 ]
Glotzer, Taya V. [3 ]
Passman, Rod S. [1 ]
机构
[1] Northwestern Univ, Dept Cardiol, Feinberg Sch Med, Chicago, IL 60611 USA
[2] Medtronic Inc, Cardiac Rhythm Dis Management, Minneapolis, MN USA
[3] Hackensack Univ, Dept Cardiol, Med Ctr, Hackensack, NJ USA
关键词
Atrial Fibrillation; Implantable Devices; Natural History; CRYPTOGENIC STROKE; PACEMAKERS; TACHYARRHYTHMIAS; PROGRESSION; ARRHYTHMIAS; STRATEGIES; ACCURACY; SYMPTOMS; INSIGHTS;
D O I
10.1002/clc.22766
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundAtrial fibrillation (AF) burden and duration are predictors of thromboembolic events. The random nature of these measures may affect clinical decision making. The objective of this study was to determine temporal changes in AF burden as detected by continuous monitoring. HypothesisAF burden changes over time when detected by continuous monitoring. MethodsA post hoc analysis of patients enrolled in the TRENDS (A Prospective Study of the Clinical Significance of Atrial Arrhythmias Detected by Implanted Device Diagnostics) study with 1 stroke risk factor(s) who were implanted with a dual-chamber cardiac rhythm management device (CRMD) and had AF burden data available for 2 years was performed. AF burden was defined as no AF, low AF (<5.5 hours on any given day), or high AF burden (5.5 hours in a day), and was first assessed over the initial 30 days following enrollment and then reassessed at 6-month intervals for 2 years. ResultsAmong 394 patients included, the average age was 70.2 10.9 years, 71% were male, and mean CHA(2)DS(2-)VASc (congestive heart failure, hypertension, age 75 years, diabetes mellitus, prior stroke or TIA, vascular disease, age 65-74 years, sex category) score was 3.7 +/- 1.6. In the 30-day baseline period, 75.1% of patients had no AF, 11.2% had low AF, and 13.7% had high AF. Over the subsequent 2 years, 40.0% of patients initially classified as no AF or low AF experienced periods with high AF, whereas 59.3% of patients initially classified as high AF experienced 6 consecutive months with no AF or low AF. Advanced age was the sole predictor of AF progression. ConclusionsSignificant temporal variability in AF burden exists when measured continuously with an implantable CRMD.
引用
收藏
页码:1044 / 1048
页数:5
相关论文
共 50 条
  • [1] The Use of Implantable Devices for Long-Term Monitoring of Cardiac Rhythm After Surgical Treatment of Atrial Fibrillation in patients With Ischemic Heart Disease
    Chernyavsky, A. M.
    Kareva, Yu. E.
    Pak, I. A.
    Rakhmonov, S. S.
    Romanov, A. B.
    Pokushalov, E. A.
    KARDIOLOGIYA, 2013, 53 (08) : 60 - +
  • [2] Long-term monitoring to detect atrial fibrillation with the indwelling implantable cardiac monitors
    Sanna, Tommaso
    INTERNATIONAL JOURNAL OF STROKE, 2018, 13 (09) : 893 - 904
  • [3] Predictors of Atrial Fibrillation During Long-Term Implantable Cardiac Monitoring Following Cryptogenic Stroke
    Riordan, Michael
    Opaskar, Amanda
    Yoruk, Ayhan
    Younis, Arwa
    Ali, Adil
    McNitt, Scott
    Sahin, Bogachan
    Rosero, Spencer
    Goldenberg, Ilan
    Aktas, Mehmet K.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2020, 9 (15):
  • [4] Detection of atrial arrhythmia for cardiac rhythm management by implantable devices
    Morris, MM
    KenKnight, BH
    Lang, DJ
    JOURNAL OF ELECTROCARDIOLOGY, 2000, 33 : 133 - 139
  • [5] Predictors and long-term clinical outcomes of newly developed atrial fibrillation in patients with cardiac implantable electronic devices
    Kim, Bum Sung
    Chun, Kwang Jin
    Hwang, Jin Kyung
    Park, Seung-Jung
    Park, Kyoung-Min
    Kim, June Soo
    On, Young Keun
    MEDICINE, 2016, 95 (28)
  • [6] Long-term rhythm monitoring with an implantable loop recorder in patients after the first clinical atrial fibrillation episode. Towards an individualized management
    Papakonstantinou, Panteleimon E.
    Simantirakis, Emmanuel N.
    MINERVA CARDIOANGIOLOGICA, 2019, 67 (02): : 121 - 130
  • [7] Long-term outcomes after surgical ablation for atrial fibrillation in patients with continuous heart rhythm monitoring devices
    Charitos, Efstratios I.
    Ziegler, Paul D.
    Stierle, Ulrich
    Graf, Bernhard
    Sievers, Hans-Hinrich
    Hanke, Thorsten
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 21 (06) : 712 - 721
  • [8] Long-term management of atrial fibrillation
    Gallagher, MM
    Camm, AJ
    CLINICAL CARDIOLOGY, 1997, 20 (04) : 381 - 390
  • [9] Utility and limitations of long-term monitoring of atrial fibrillation using an implantable loop recorder
    Lee, Randall
    Mittal, Suneet
    HEART RHYTHM, 2018, 15 (02) : 287 - 295
  • [10] Treatment of atrial fibrillation with an implantable atrial defibrillator: long-term results
    Geller, JC
    Reek, S
    Timmermans, C
    Kayser, T
    Jung, W
    Camm, AJ
    Wellens, HJJ
    Klein, HU
    EUROPEAN HEART JOURNAL, 2003, 24 : 599 - 599