Emulations of Overvoltage and Overcurrent Relays In Transmission Lines

被引:0
|
作者
Amreiz, H. [1 ]
Janbey, A. [1 ]
Darwish, M. [2 ]
机构
[1] London Coll UCK, Dept Engn, London, England
[2] Brunel Univ, Elect & Comp Engn, London, England
关键词
over voltage relay; under voltage relay; over current relay;
D O I
10.1109/UPEC55022.2022.9917757
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An "Over Voltage Relay" is one of the protective relays which operates when the voltage exceeds a preset value. In a typical application the over voltage relay is used for over voltage protection, which is connected to a potential transformer, and calibrated to operate at or above a specific voltage level. An "Under Voltage Relay" and an "Over Current Relay" are also protective relays which operate when the voltage is reduced, or the current is increased below or above a preset value. In a typical application these relays are connected to potential transformers, and calibrated to operate at, above or below a specific voltage or current levels. The emulator used in paper simulated experiments of all three types of relays mentioned above. The transmission line emulator used in this paper is an HVAC transmission line of length of 180 km. The transmission line of the emulator can be used as a 3-phase transmission line of 180 km length or as a single-phase transmission line of 540 km long. This transmission line in the emulator is divided into 6 pi sections and each pi section is 30 km long. The line inductance of the transmission line of the emulator is examined for every 30 km and the line capacitance is examined for every 15 km. The line parameters of the emulator (RLC) for the 400kV transmission line are: 0.02978 O/km, 1.06 mH/km and 0.0146 mu F/ km, respectively.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] GENERATOR GROUND FAULT PROTECTION USING OVERCURRENT, OVERVOLTAGE, AND UNDERVOLTAGE RELAYS
    GRIFFIN, CH
    POPE, JW
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (12): : 4490 - 4501
  • [2] IEEE/PSRC Working Group report on considerations in setting instantaneous overcurrent relays on transmission lines
    Apostolov, AP
    Behrendt, K
    Boyle, JR
    Chano, SR
    Darlington, AN
    Domin, T
    Elmore, WA
    Gray, L
    Lowe, WG
    McDonald, MJ
    Shuh, HM
    Strang, WM
    Engel, P
    Haas, RW
    Hasenwinkle, I
    Hedding, R
    Jackson, B
    Krizauskas, E
    Wardlow, JD
    Stephens, JE
    Zocholl, S
    IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (01) : 116 - 125
  • [3] Spline Function based Technique for sensitizing of Ground Overcurrent relays for sub-transmission and distribution lines
    Khanna, Abhishek
    2007 POWER SYSTEMS CONFERENCE - ADVANCE METERING, PROTECTION, CONTROL, COMMUNICATION, AND DISTRIBUTED RESOURCES, 2007, : 69 - 77
  • [4] Overvoltage Suppression for UHV Transmission Lines
    李永丽
    刘太华
    李仲青
    景雷
    龙英
    范建忠
    Transactions of Tianjin University, 2008, (03) : 222 - 225
  • [5] Overvoltage suppression for UHV transmission lines
    Li Y.
    Liu T.
    Li Z.
    Jing L.
    Long Y.
    Fan J.
    Trans. Tianjin Univ., 2008, 3 (222-225): : 222 - 225
  • [6] COORDINATION OF DIRECTIONAL OVERCURRENT RELAYS IN TRANSMISSION-SYSTEMS - A SUBSYSTEM APPROACH
    RAMASWAMI, R
    DAMBORG, MJ
    VENKATA, SS
    IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (01) : 64 - 71
  • [7] The Effects of Harmonics On Overcurrent Relays
    Wannous, Kinan
    Toman, Petr
    2016 17TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2016, : 239 - 244
  • [8] Performance of Overvoltage Transducer for Overhead Transmission Lines
    Chen, Shao Qing
    Li, Jian Ming
    Luo, Tao
    Zhou, Hui Ying
    Ma, Qi Xiao
    Du, Lin
    2013 IEEE INTERNATIONAL CONFERENCE ON APPLIED SUPERCONDUCTIVITY AND ELECTROMAGNETIC DEVICES (ASEMD), 2013, : 48 - 51
  • [9] VHDL modeling of overcurrent relays
    Manzoul, MA
    Padmanaban, S
    COMPUTER APPLICATIONS IN INDUSTRY AND ENGINEERING, 2000, : 234 - 237
  • [10] Optimal Combined Overcurrent and Distance Relays Coordination Incorporating Intelligent Overcurrent Relays Characteristic Selection
    Chabanloo, Reza Mohammadi
    Abyaneh, Hossein Askarian
    Kamangar, Somayeh Sadat Hashemi
    Razavi, Farzad
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (03) : 1381 - 1391