Performance characteristics and working fluid selection for high-temperature organic Rankine cycle driven by solar parabolic trough collector

被引:6
|
作者
Zhao, Wei [1 ]
Xie, Ning [1 ]
Zhang, Wei [1 ]
Yue, Jingpeng [1 ]
Wang, Lingbao [2 ]
Bu, Xianbiao [2 ]
Li, Huashan [2 ]
机构
[1] Elect Power Res Inst Guangdong Power Grid Co Ltd, Guangzhou 510080, Peoples R China
[2] Chinese Acad Sci, Guangzhou Inst Energy Convers, Guangzhou 510640, Peoples R China
关键词
performance characteristics; working fluid selection; organic Rankine cycle; parabolic trough collector; multi-objective optimization; PLATE HEAT-EXCHANGERS; THERMODYNAMIC ANALYSIS; MULTIOBJECTIVE OPTIMIZATION; WASTE HEAT; SYSTEM; DESIGN;
D O I
10.1093/ijlct/ctab036
中图分类号
O414.1 [热力学];
学科分类号
摘要
In present paper, thermodynamic analysis and techno-economic assessment of an organic Rankine cycle (ORC) coupled with solar parabolic trough collector (PTC) are investigated. The thermodynamic and economicmodels, based on the principles of thermodynamics and heat transfer, aswell as dynamic economic analysis, are developed for the components of the combined system. By performing a parametric study, the effects of outlet temperature (T-PTC,T-out) and temperature difference between inlet and outlet of PTC (Delta T) and pinch point temperature difference of heat exchangers on the thermo-economic performance are evaluated. Moreover, under reasonable thermodynamic boundary conditions, the optimal operational parameters are obtained via a Pareto frontier solution. It is indicated that the improving TPTC, out is beneficial to the thermo-economic performance. Among the fluid candidates, toluene yields the best energy, exergetic and economic performance. There exists an optimal Delta T at which the thermal and exergy efficiency achieve the maximum. The optimal Delta T is 19-26 degrees C for the screened working fluids. The pinch point temperature difference of evaporator has different impact on the system performance compared with that of condenser. The evaporator pinch point temperature difference has slight influence on the economic performance when it is larger than 10 degrees C. While there is optimized condenser pinch point temperature difference (7-8 degrees C), the economic performance is the optimal. The PTC and heat exchanger are the main source of total investment cost, account for more than 75%. The Pareto frontier solutions can provide a design guide for the decision maker.
引用
收藏
页码:1135 / 1149
页数:15
相关论文
共 50 条
  • [1] SIZING A PARABOLIC TROUGH COLLECTOR FOR A MICRO SOLAR ORGANIC RANKINE CYCLE
    Chai, Choi Yun
    Jung, Hyung-chul
    JURNAL TEKNOLOGI, 2019, 81 (02): : 123 - 133
  • [2] Selection of working fluid and performance analysis of solar supercritical organic rankine cycle
    College of Energy and Power Engineering, North China Electric Power University, Baoding
    071003, China
    Taiyangneng Xuebao, 8 (2002-2007):
  • [3] Performance Evaluation and Optimization of a Novel System Combining a Photovoltaic/Thermal Subsystem & an Organic Rankine Cycle Driven by Solar Parabolic Trough Collector
    Zhijian Liu
    Tianhe Wei
    Di Wu
    Yulong Zhang
    Guiqiang Li
    Xinyan Yang
    Journal of Thermal Science, 2021, 30 : 1513 - 1525
  • [4] Performance Evaluation and Optimization of a Novel System Combining a Photovoltaic/Thermal Subsystem & an Organic Rankine Cycle Driven by Solar Parabolic Trough Collector
    Liu, Zhijian
    Wei, Tianhe
    Wu, Di
    Zhang, Yulong
    Li, Guiqiang
    Yang, Xinyan
    JOURNAL OF THERMAL SCIENCE, 2021, 30 (05) : 1513 - 1525
  • [5] Performance Evaluation and Optimization of a Novel System Combining a Photovoltaic/Thermal Subsystem & an Organic Rankine Cycle Driven by Solar Parabolic Trough Collector
    LIU Zhijian
    WEI Tianhe
    WU Di
    ZHANG Yulong
    LI Guiqiang
    YANG Xinyan
    JournalofThermalScience, 2021, 30 (05) : 1513 - 1525
  • [6] Performance study on eutectic molten salt as a high temperature working fluid in the parabolic trough collector
    Jebasingh, V. K.
    Johns, J. Divya
    Arunkumar, T.
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2019, 43 (01) : 764 - 768
  • [7] THERMODYNAMIC ANALYSIS OF A PARABOLIC TROUGH SOLAR COLLECTOR POWER GENERATION PLANT COUPLED WITH AN ORGANIC RANKINE CYCLE
    Alashkar, Adnan
    Gadalla, Mohamed
    PROCEEDINGS OF THE ASME POWER CONFERENCE, 2018, VOL 1, 2018,
  • [8] Working fluid selection for low temperature transcritical organic Rankine cycle
    Liu, Chao
    Xu, Jinliang
    Chen, Qicheng
    Miao, Zheng
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2013, 33 (23): : 37 - 43
  • [9] Small Organic Rankine Cycle Coupled to Parabolic Trough Solar Concentrator
    Caldino-Herrera, U.
    Castro, Laura
    Jaramillo, O. A.
    Garcia, J. C.
    Urquiza, Gustavo
    Flores, Francisco
    4TH INTERNATIONAL SEMINAR ON ORC POWER SYSTEMS, 2017, 129 : 700 - 707
  • [10] Performance analysis of solar parabolic trough collectors driven combined supercritical CO2 and organic Rankine cycle
    Singh, Harwinder
    Mishra, R. S.
    ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2018, 21 (03): : 451 - 464