共 50 条
The carbon isotope composition of CO2 respired by trunks:: comparison of four sampling methods
被引:20
|作者:
Damesin, C
Barbaroux, C
Berveiller, D
Lelarge, C
Chaves, M
Maguas, C
Maia, R
Pontailler, JY
机构:
[1] Univ Paris 11, CNRS, UMR C8079, ESE, F-91405 Orsay, France
[2] Univ Tecn Lisboa, Inst Super Agron, Inst Tecnol Quim & Biol, Qeiras, Portugal
[3] Inst Biotechnol Plantes, UMR 8618, F-91405 Orsay, France
[4] Inst Tecnol Quim & Biol, Oeiras, Portugal
[5] ICAT, FCUL, Lab Isotopos Estaveis, P-1749016 Lisbon, Portugal
关键词:
D O I:
10.1002/rcm.1799
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
The C-13 natural abundance of CO2 respired by plants has been used in the laboratory to examine the discrimination processes that occur during respiration. Currently, field measurements are being expanded to interpret the respiration delta(13)C Signature measured at ecosystem and global levels. In this context, forests are particularly important to consider as they represent 80% of the continental biomass. The objective of this investigation was to compare four methods of sampling the CO2 respired by trunks for the determination of its carbon isotope composition: three in situ methods using chambers placed on the trunk, and one destructive method using cores of woody tissues. The in situ methods were based either on a Keeling plot approach applied at the tissue level or on an initial flush of the chamber with nitrogen or with CO2-free air. In parallel, we investigated the possibility of an apparent discrimination during tissue respiration by comparing the delta(13)C signature of the respired CO2 and that of the organic matter. The study was performed on six tree species widely distributed in temperate and mediterranean areas. The four methods were not significantly different when overall means were considered. However, considering the individual data, the Keeling plot approach and the nitrogen flush methods gave fairly homogeneous results, whereas the CO2-free air method produced more variable results. The core method was not correlated with any of the chamber methods. Regardless of the methodology, the respired CO2 generally was enriched in C-13 relative to the total organic matter. This apparent enrichment during respiration was variable, reaching as much as 3-5parts per thousand. This study showed that, on the whole, the different sampling techniques gave similar results, but one should be aware of the variability associated with each method. Copyright (C) 2005 John Wiley Sons, Ltd.
引用
收藏
页码:369 / 374
页数:6
相关论文