Enantioselective resolution of thyroxine hormone by high-performance liquid chromatography utilizing a highly fluorescent chiral tagging reagent

被引:8
|
作者
Jin, Dongri
Zhang, Meina
Jin, Shanji
Lee, Min-Kwon
Song, Goon-Cheol
Back, Gernho
Lee, Yong-Ill [1 ]
机构
[1] Changwom Natl Univ, Dept Chem, Changwom 641773, South Korea
[2] Yanbin Univ, Minist Educ, Key Lab Organism Funct Factors Changbai Mt, Yanji 133002, Peoples R China
[3] Yanbian Univ, Affiliated Hosp, Dept Nucl Med, Yanji 133000, Peoples R China
关键词
fluorescent chiral tagging reagent; precolumn derivatization; thyroxine enantiomers; HPLC; fluorescence detection;
D O I
10.1002/chir.20414
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
A highly fluorescent chiral tagging reagent, 4-(3-isothiocyanatopyrrolidin-1-yl)-7-(N,N-dimethylaminosulfonyl-2,1,3-benzoxadiazole, [R(-)-DBD-PyNCS], was employed to develop an indirect resolution method for efficient separation of thyroxine enantiomers,D-T-4 and L-T-4. The reaction of R(-)-DBD-PyNCS with the thyroxine enantiomers proceeds effectively at 40 degrees C for 20 min in the presence of basic medium to produce the corresponding pair of diastereomers. No racemization occurs during the tagging reaction under the optimized conditions. Various experimental parameters for derivatization reaction including the species of catalyst, the concentration of tagging reagent and reaction temperatures, have been examined to get a highest yield for T-4 derivatives. The structure of T4 derivatives was identified based on ESI-MS/MS measurements in negative mode. The efficient separation of D-, L-T-4 derivatives was achieved by isocratic elution with water-acetonitrile mobile phase containing 1% AcOH on a reversed phase column utilizing a conventional fluorescence detector. The resolution (Rs) value of the diastereomers derived from thyroxine was 5.1. The calibration curves of both the D-T4 and L-T4 were linear over the concentration range of 0.1-20 mu g/ml. The limits of detection (S/N = 3) for both D-T-4 and L-T-4 were 0.2 ng per injection. The proposed method was applied to the determination of D-T-4 and L-T-4 in pharmaceutical formulations and human serum samples.
引用
收藏
页码:625 / 631
页数:7
相关论文
共 50 条
  • [1] Indirect resolution of thiol enantiomers by high-performance liquid chromatography with a fluorescent chiral tagging reagent
    Jin, DR
    Toyo'oka, T
    ANALYST, 1998, 123 (06) : 1271 - 1277
  • [2] Resolution of thyroxine hormone enantiomers by precolumn derivatization with a fluorescent chiral reagent using reversed-phase high performance liquid chromatography
    Jia Shaodong
    Zhang Meina
    Jin Dongri
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (05) : 559 - 562
  • [3] Determination of R-(+)-higenamine enantiomer in Nelumbo nucifera by high-performance liquid chromatography with a fluorescent chiral tagging reagent
    Hong, Haixin
    Lee, Yong-Ill
    Jin, Dongri
    MICROCHEMICAL JOURNAL, 2010, 96 (02) : 374 - 379
  • [4] RESOLUTION OF ENANTIOMERS OF ALCOHOLS AND AMINES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AFTER DERIVATIZATION WITH A NOVEL FLUORESCENT CHIRAL REAGENT
    TOYOOKA, T
    LIU, YM
    HANIOKA, N
    JINNO, H
    ANDO, M
    IMAI, K
    JOURNAL OF CHROMATOGRAPHY A, 1994, 675 (1-2) : 79 - 88
  • [5] Chiral separation by high-performance liquid chromatography of D/L-amino acids labelled with a chiral fluorescent reagent
    Toyo'oka, Toshimasa
    Jin, Dongri
    Nagakura, Kayoko
    Murofushi, Sumiyo
    Biomedical Chromatography, 1999, 13 (02): : 103 - 104
  • [6] Enantioselective separation and analysis of chiral pesticides by high-performance liquid chromatography
    Ye, Jing
    Wu, Jing
    Liu, Weiping
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2009, 28 (10) : 1148 - 1163
  • [7] Enantiomeric resolution of chiral pesticides by high-performance liquid chromatography
    Wang, P
    Jiang, SR
    Liu, DH
    Zhang, HJ
    Zhou, ZQ
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (05) : 1577 - 1583
  • [8] Advances in resolution of catecholamines by chiral high-performance liquid chromatography
    王海波
    王大力
    张小勇
    金东日
    延边大学学报(自然科学版), 2004, (03) : 182 - 186
  • [9] Chiral separation of lipoxygenase metabolites utilizing high-performance liquid chromatography
    Myrdal, Paul B.
    Angersbach, B. Steven
    Karlage, Kelly
    Kuehl, Philip J.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1132 (1-2) : 315 - 319
  • [10] Resolution of racemic thyroxine with chiral additive as mobile phase by high performance liquid chromatography
    Wang, R
    Xie, JW
    Jia, ZP
    Hu, XL
    Chen, LR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (04) : 406 - 409